EMC Test Equipment

(Showing 12 of 1202)
Show 12 24 36 48 96

EMC Test Equipment Categories

EMC Test Equipment Test Equipment, Systems & Solutions

  • Amplifier Research FP7060 E-Field Probe Kit, 27 MHz – 60GHz, 0.7–300 V/m

    SKU: 11650

    Weight: 350g approx
    Application/Test Type: electric field measurement instrument for use in EMC and EMI applications
    Battery: 2 built-in NiMH batteries, size AA, rechargeable, changed by operator, 40 hours operating life per charge.
    Communication: 10 m glass cable
    Dimensions: Approx. 420 x 85 x 65 mm including base and probe
    Frequency Range: 27MHz–60GHz
    Measurement Mode: composite values
    Operation Time: 40 hours operating life per charge.
    Recharging Time: Standard recharger included, 3 hour charge time
    RF Field Probes: E-Field
    Sampling Rate: 60Hz, 50Hz, 5 Hz. - user selectable
    Sensors: Isotropic
  • Amplifier Research 20S1G4 Solid State RF Amplifier

    SKU: sku-610

    Weight: 37 lbs
    Dimensions: 19.8 x 6.1 x 14.8 in
    Flatness: ± 1.5 dB
    Frequency Range: 0.7–4.2GHz instantaneously
    Gain: (at maximum setting) 43 dB minimum (Continuous Range) 10 dB minimum
    Harmonic Distortion (THD): Minus 20 dBc maximum at 15 watts
    Impedance: 50 ohms, VSWR 2.0:1 maximum
    Input: 90-132, 180-264 VAC 50/60 Hz, single phase 210 watts maximum
    Output: POWER OUTPUT @ 3dB COMPRESSION Nominal 25 watts Minimum 20 watts POWER OUTPUT @ 1dB COMPRESSION Nominal 22 watts Minimum 18 watts
    RF Connector: RF Connector Type N female REMOTE INTERFACES: IEEE-488-24 pin female RS-232-9 pin Subminiature D (female) RS-232 (fiber optic)-Type ST USB 2.0-Type B Ethernet-RJ-45
    RF Input Voltage: 1.0 milliwatt maximum for rated output
    Standards Met: CE Mark Testing
    Call for availability
  • 3ctest MFS Series Magnetic Field Simulator for IEC 61000-4-8

    SKU: sku-594

    Weight: Approx. 35Kg+68Kg
    Coil Factor: 1000 x 1000mm
    CRO Trigger: Automatic, manual or external signal trigger
    Dimensions: 19 inch/6U/4U
    Magnetic Field Strength: varies per coil: TCXS111 single turn1m*1m square coil: 1-100A/m continuous, 100-400A/m(1-10 short time) TCXS113three-turn 1m*1m square coil: 1-300A/m continuous, 300-1200A/m 1~10s short time
    Max input power: 100W
    Output Current: 50Hz/60Hz sine wave +/- 5%
    Repetition time: 1-9999s
    Standards Met: IEC/EN 61000-4-8, GB/T 17626.8
    Test duration: 1-28800s
    Generic Standards: IEC 61000-6-1, IEC 61000-6-2
    6-8 Weeks
  • 3ctest PFS 2216SVD Single Phase Power Fail Simulator w/ Two Semiconductor Switches for High Current Protection

    SKU: sku-591

    Weight: 40Kg
    Communication: Ethernet LAN、RJ45
    Coupling: BNC
    Dimensions: 19 inch/6U
    Dips, Interrupts & Variations: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29
    Frequency: 45-65Hz
    General Data: Technical Details
    Input: BNC,5V TTL
    Mains & EUT Connections: 4mm banana line
    Maximum Continuous Power: 100W
    Output Current: 16A AC/DC continuous current; 20A continuous 5s 40Acontinuous 3s
    Peak inrush current capability: 500 Amps
    Phase synchronization: 0°- 360°,1° step or random
    Repetition time: 0.3-9999 cycle or 5ms-9999ms
    Rise time: 1-5us(100Ω load)
    Supply Voltage: 110V/220V, ±10%, 50/60Hz
    Test duration: 50ms-50000ms
    Test Voltage: 250V AC,300V DC
    Trigger: BNC,5V TTL
  • 3ctest PFS 2216SD Power Fail Simulator for EN/IEC 61000-4-11

    SKU: sku-590

    Mains & EUT Connections: 4mm banana line
    Output Current: 16A AC/DC continuous current; 20A continuous 5s 40Acontinuous 3s
    Peak inrush current capability: 500 Amps
    Rise time: 1-5us(100Ω load)
    Test duration: 50ms-50000ms
    Test Voltage: 250V AC,300V DC
    Trigger: BNC,5V TTL
    Inquire for Availability
  • 3ctest PFS 6030A Power Failure Simulator for Voltage Dips & Drops,60 V / 30 A

    SKU: sku-588

    Test voltage: Voltage drop: 1V max@30A
    Weight: 20 kg
    Dimensions: 19" / 4 U
    Output: DUT voltage monitoring output: BNC,10:1 coaxial terminal output DUT current monitoring output: BNC,10A:1V coaxial terminal output
    Peak current: 60A duration time 500 ms
    Pulse duration: Drop duration time td 1us - 10 s
    Repetition rate: 100 ms - 999s
    Source Impedance: High resistance or low resistance
    Test Voltage: 0–60 V
    Trigger: External trigger signal by oscilloscope, BNC,5V TTL
    Trigger of bursts: Automatic, manual, external
  • Amplifier Research (AR) 40WD1000, DC - 1000 MHz RF Power Amplifier, 40 Watt CW

    SKU: sku-587

    Weight: 64 lb
    Communication: Remote control: 25 Pin Subminiature D on rear panel
    Dimensions: 19.8 x 9.8 x 18.0 in
    Flatness: ±1.0 dB typical ±1.5 dB maximum
    Frequency Range: DC-1000 MHz
    Gain: 47 dB minimum
    Impedance: INPUT IMPEDANCE: 50 ohms, VSWR 2.0:1 maximum OUTPUT IMPEDANCE: 50 ohms, nominal
    Input: 90 to 132; 180 to 264 VAC 50/60 Hz, single phase 700 watts maximum
    Output: 40 watts minimum
    RF Connector: Type N female on front panel
    RF Input Voltage: 1.0 milliwatt maximum for rated output
  • AH Systems SAS-545 1 GHz Biconical Antenna

    SKU: sku-573

    Weight: 1.6 lb.'s (725 g)
    Antennas: Biconical Antennas
    Application/Test Type: Radiated emissions and immunity
    Connector: N-type (female)
    Dimensions: Height: 15 in. (38.1 cm) Width: 14 1/4 in. (36.25 cm) Depth: 7 11/16 in. (19.5 cm)
    Frequency Range: 30 MHz - 1GHz
    Gain: -50 to 2.5 dBi
    Impedance: 50 Ohms nominal
    Maximum Continuous Power: 200 Watt
    Mounting Base: ABC-B Mounting Clamp with ¼ - 20 Thread, female
  • Teseq AMZ 41A Absorbing Clamp for CISPR 13 & 14, w/ LE 210 RF Cable

    SKU: 30080

    Weight: approx. 7 kg
    Application/Test Type: Disturbance power measurements of coaxial cables, automotive screened components (eg motor ignition systems and sheath current on aerial cables.
    Clamp factor (CF): -4 dB to +5 dB
    Current Rating: 25 Amps Max
    Decoupling factor DF: Greater than 21 dB
    Decoupling factor DR: Greater than 30 dB
    Dimensions: W x D x H: 665 mm x 120 mm x 105 mm
    Frequency Range: 30 MHz to 1000 MHz
    Isolated lines under test: Power supply lines and other connecting lines
    Max. Cable Diameter: 20 mm inner (10 mm with adapter)
    Maximum Continuous Power: 10 Watts
    Min. site attenuation: 13 dB to 22 dB
    RF Connector: BNC, 50 Ω
    Standards Met: CISPR 13, CISPR 14-1, CISPR 16-1-5, CISPR 16-2-2
    Inquire for Lead Time