EMC Test Equipment

(Showing 12 of 1193)
Show 12 24 36 48 96

EMC Test Equipment Categories

EMC Test Equipment Test Equipment, Systems & Solutions

  • Diamond Engineering DAMS Antenna Measurement Studio

    SKU: 31971

    Features: 2D & 3D AZ-EL-F Plotting, Gain Calculation, Pathloss Calculators, Radar Cross-section Profiling, Beam Width vs Frequency and More
    Control Interface: USB/serial via DAMS controller
    Supported Data Formats: XLS (Excel), TXT (ASCII), S1P, DAMS formats
    Capabilities: Antenna Turntable/ Platform Movement, Data Collection, Data Calculation, Data Visualization, Data Manipulation, Import & Export Features
    Precision Antenna Turntables: DAMS 7000 DAMS 6000, DAMS 5000
    Immediate Download
  • Keysight N1914A EPM Series RF Power Meter

    SKU: 10939

    Frequency Range: DC to 120 GHz (sensor dependent)
    Dynamic Range: -70 to +44 dBm (sensor dependent)
    Interfaces: GPIB, LAN LXI-C and USB connectivity
    Channels: 2 (Expandable to 4)
    $695.00 - $6,295.00
    In Stock
  • Amplifier Research PL7004 800MHz - 3.6GHz Electric Field Pulse Laser Powered Probe

    SKU: 11935

    Amplitude Accuracy: Without correction factors applied: ±1.5 dB @ 1 GHz; With correction factors applied: Typical expanded measurement uncertainty (95% confidence interval), 0.8 dB, 800 MHz–1 GHz; 1.4 dB, 1GHz–3.6 GHz
    Damage Level: 1000 V/m, Continuous Field or Pulsed Field
    Frequency Range: 800MHz - 3.6GHz
    Isotropic Deviation: ±1.0 dB @ 1 GHz. For improved accuracy, this probe should be used with a single axis aligned with the E-field being measured.
    Operating Range: 80–800 V/m
    Pulse Duration: 0.02% to 2%
    Pulse Period: Up to 5 milliseconds between pulses (greater than 200 Hz pulse rate)
    Pulse Width: 1 to 100 Microseconds
    Relative Flatness: ±2.5 dB, 800 MHz-3 GHz; ±3.0 dB, 3.0GHz 3.6GHz
    Temperature Stability: +0.5 dB Over Operating Temperature Range
    Inquire for Availability
  • Amplifier Research FL7030 5 kHz - 30 MHz Electric Field Laser Powered Probe

    SKU: 11934

    Weight: 62.5 g (2.2 oz)
    Accuracy: ±1.0dB @ 10MHz1 0.8dB, 100kHz–1GHz3,4 1.4dB, 1GHz–6GHz3,4
    Analog Response Time: 20 msec/up to 50 samples per second, at FI7000 USB and GPIB interfaces
    Calibration Data: Accredited Calibration Report (A2LA) supplied with probe
    Damage Level: 1000 V/m continuous field
    Data Returned From Probe: X, Y, Z axes, and Composite
    Dimensions: 5.7 x 5.7 x 5.7 cm (2.25 x 2.25 x 2.25 in) 2.92 cm (1.15 in) DIA spherical housing 3.18 cm (1.25 in) sensor radome per axes
    Fiber Optic Connectors: Two E2000 compact duplex connectors at 1 meter, includes fiber optic verification loop.
    Isotropic Deviation: ± 0.5 dB @ 10 MHz ± 0.5 dB, 5 kHz–30 MHz (typical)
    Linearity: ± 0.5 dB and ± 0.9 V/m
    Operating Range: 1.5–300 V/m
    Operating Temperature: 10˚C to 40˚C (50˚F to 104˚F) @ 5% to 95% RH non-condensing
    Power Requirements: Laser powered from FI7000 interface
    Rise time: Typical Analog 300nS
    Temperature Stability: ± 0.5 dB over operating temperature range
  • Amplifier Research FA7006 6 GHz E-Field Probe Kit

    SKU: 11933

    Test Standards: IEC 61000-4-3
    Accuracy: ±1.0dB @ 10MHz1 0.8dB, 100kHz–1GHz3,4 1.4dB, 1GHz–6GHz3,4
    Damage Level: 1000 V/m
    Dimensions: 5.7 x 5.7 x 5.7cm
    Linearity: ±0.5dB
    Minimum Pulse Width: 2μs
    Operating Range: 9 – 900V/m
    Rise time: Typical Analog 300nS
    Temperature Stability: ±1.0dB, 10°C - 40°C8
    Typically In Stock
  • E&I / ENI 2100L RF Power Amplifier 10 kHz - 12 MHz, 100 Watts

    SKU: sku-844

    Connectors: BNC
    Cooling: Forced Air
    Flatness: ± 1.5 dB
    Frequency range: 10 kHz - 12 MHz
    Gain: 50 dB nominal
    Gain Flatness: +/- 1.5 dB
    Input: 104-240 Volts
    Input Power for Rated Pout: 0 dBm (1 mW)
    Output: 100 Watts P1dB
    Protection: Unit will withstand input signal of +13 dBm without damage (1.0 V rms) max.
    Rated Power: 100 Watts P1dB Compression
    RF Input Signal: AM, FM, SSB, Pulsed
    RF Input Voltage: 1 mW
    $795.00 - $10,950.00
    In Stock