EMC Partner IMU4000 Overview
The EMC Partner IMU4000 is an innovative fully modular test system, easily upgradable on site without significant work or recalibration. Electrostatic discharge, burst, surge, dips, drops, variations, magnetic field and pulse, common mode and differential mode tests can now be performed with only one generator, fast and comfortable. It completes our compact immunity family. Based on the user friendly touch panel and colour graphics interface, IMU4000 builds on the success of the EMC PARTNER Operating System (EPOS). Modular architecture is a time and money saving feature, enabling on-site upgrades of ESD, EFT, CWG, AC/DC DIPS, INTERRUPTS, VARIATIONS and COMMON MODE circuits.
Easy navigation using the touch panel or rotary knob is supplemented by the ability to change parameters during test. Surge voltages up to 4kV combined with EFT up to 5kV make IMU4000 the automatic choice for manufacturers and developers seeking a flexible and reliable test solution. Fully integrated into the all new TEMA 3000 software with DSO control and custom report generator, IMU4000 is the perfect addition to any test laboratory. EMC PARTNER IMU family compact immunity testers are available as 4kV, 6kV and 8kV models.
Common Standards |
EN/IEC 61000-4-4, EN/IEC 61000-4-5, EN/IEC 61000-4-11, CE Mark, optional EN/IEC 61000-4-16 |
Control Features |
|
User Interface |
7” Colour touch panel |
Operating System |
EMC PARTNER (EPOS) |
Communication Interface |
Ethernet |
Accessory control interface |
RS485 |
Atmospheric measurement |
Temperature, humidity, pressure (with accessory) |
BNC monitor ports |
EUT plus IMPULSE voltage & current |
Synchro on / off |
0° up to 360° |
Integrated CDN: |
|
AC Voltage and Current |
300V/16A; 50 to 400Hz |
DC Voltage and Current |
300V/16A |
Maximum EUT current |
16A |
Frequency range |
DC up to 60Hz |
Power frequency synchro |
DC up to 60Hz |
Coupling EFT |
L, N, PE, L+N, L+PE, N+PE, L+N+PE, direct |
Coupling CWG |
L-N, L-PE, N-PE, direct |
Additional Capabilities |
|
EFT Burst 5/50ns: |
|
Standards |
EN/IEC 61000-4-4, and EN 61000-6-1,-6-2, CEMark |
Voltage Waveform into 50Ω load |
5ns Rise Time ±30%, 50µs pulse width ±30% |
Voltage Waveform into 1000Ω load |
5ns Rise Time ±30%, 50µs pulse width ±30% |
Voltage Amplitude |
250-4,400V ±10%, 125V-2,200V ±10% into 50Ω |
Burst Duration |
td = 0.10ms – 30ms |
Burst Period |
tr = 1ms – 1,000ms |
Frequency |
f = 0.1kHz - 1,000kHz |
Combination Wave Surge: |
|
Standards |
EN/IEC 61000-4-5 , EN 61000-6-1, -6-2, CEMark |
Open Circuit Voltage Waveform |
250V – 4,100V, Front Time1.2us ±30%, 50µs Duration ± 20% |
Short Circuit Current Waveform |
125A- 2050A, 8µ Front Time ±20%, 20µs Duration ±20% |
Peak Open Circuit Voltage |
250V–4100V ±10% |
Peak Short Circuit Current |
125A–2050A ±10%@2Ω, 20.8-500A ±10%@12Ω |
Pulse Repetition Rate |
MAX. 1Hz (1s – 999s) |
Peak Voltage and Current Monitoring |
5,000V, 2,500A in the LCD Display |
Monitoring of EUT voltage and current |
Built-in 100:1 voltage measurement 10mV/A, max. 1,000A |
Dips and Interrupts: |
|
Standards |
EN IEC 61000-4-11 EN 61000-6-1, -6-2, CEMark |
Nominal current |
6 Amps Max. |
Interruption Time |
50µs up to 30s |
Phase angle interruption |
0 to 360 degrees |
Rise/ Fall Time |
1 to 5µs |