Langer EMV ICI I900 L-EFT Pulse Current Probe Set

Manufacturer:
Langer EMV
  • 1x ICI I900 L-EFT, Pulse Current Source (FBBI)
  • 1x BPS 202, Burst Power Station
  • 1x BPS 202-Client, BPS 202-Client Software / USB
  • 1x NT Ex EU, Power Supply Unit
  • 1x ICI 01 L-EFT acc, Accessories
  • 1x ICI case, System Case
  • 1x ICI m, ICI Set User Manual
Repetition Frequency:
0.1 Hz - 20 kHz
Rise time:
< 2 ns
Polarity (set by software):
+ / - / alternating
Trigger-pulse delay (typ.):
100 ns (probe-specific) - 450 ns
Supply voltage:
BPS 202
Software:
BPS 202-Client / DLL (32 Bit / 64 Bit) Win XP SP3 or higher

 

No reviews yet Write a Review
Availability:

In Stock

SKU:
2511-2

 

 

Due to tariff increases, some items in our catalog are subject to additional costs when purchased.


Getting Started...

Check out our Google Reviews

Overview

The Langer EMV ICI I900 L-EFT set includes an ICI pulse current source that emits current pulses. This allows very accurate and high resolution IC analysis and body biased injection to be performed, e.g. for testing safety-critical circuits. Special features are the high-resolution tip (for testing extremely small areas) and a very low trigger-to-pulse jitter (to specifically disturb the program flow).

ICI I900 L-EFT Pulse Current Source (FBBI)

ICI I900 L-EFT
Pulse Current Source (FBBI)
The ICI I900 L-EFT pulse current source couples fast transient pulses into a test IC (Forward body biased injection). This source allows for side channel analysis or testing the immunity of individual areas of the IC.

BPS 202 Burst Power Station

BPS 202
Burst Power Station
The BPS 202 is used as power supply and control unit for the Langer EMV-Technik GmbH pulse probes. The control unit is connected to the user PC via an USB interface. BPS 202-Client software does the controlling.

With the BPS 202 input “sync” interference pulses of the connected probes can be synchronized on the functional process of an IC.

Adjustment of the pulse frequency and pulse current

  • Single pulse or pulse sequence
  • External triggering possible
  • Adjustable trigger delay
 BPS 202-Client BPS 202-Client Software / USB
BPS 202-Client Client Software/ USB
The BPS 202-Client software is used to control the BPS 202 Burst Power Station and thereby the connected probe. The software is installed on the user PC.

Scope of delivery:

1x ICI I900 L-EFT, Pulse Current Source (FBBI)
1x BPS 202, Burst Power Station
1x BPS 202-Client, BPS 202-Client Software / USB
1x NT Ex EU, Power Supply Unit
1x ICI 01 L-EFT acc, Accessories
1x ICI case, System Case
1x ICI m, ICI Set User Manual

Key Considerations

Manufacturer:
Langer EMV
Repetition Frequency:
0.1 Hz - 20 kHz
Rise time:
< 2 ns
Polarity (set by software):
+ / - / alternating
Trigger-pulse delay (typ.):
100 ns (probe-specific) - 450 ns
Supply voltage:
BPS 202
Software:
BPS 202-Client / DLL (32 Bit / 64 Bit) Win XP SP3 or higher