Condition:
Used
Test Capabilities:
Combination Wave Surge Immunity , EFT/Burst, Dips Interrupts & Variations
EMC Standards:
IEC 61000-4-5, IEC 61000-4-4, IEC 61000-4-11
Test Setup Guides:
Electrical Transient and Noise, Surge Immunity, Power Failures
EFT/Burst Pulse Output Capability:
±200 V to 4.8 kV (in 1 V steps) - open circuit±100 V to 2.4 kV ±100 A to 2.2 kA
Combination/Wave Surge Output Capability:
250 V - 6,000 V ± 10%
External Coupling:
Data Lines (EFT & Surge), 3PH EUT
Phase synchronization:
0° - 360°, resolution 1° (16 - 500Hz)
Ringwave 0.5 ÎĽs/100 kHz:
Pulse conforms to IEC/EN 61000-4-12 and ANSI (IEEE) C62.41
Telecom Surge:
As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendations
Manufacturer:
EM Test
Online Orders Ship Same Day

 

Availability:

Inquire for Availability

SKU:
sku-241

 

This product is available for shipping to North America and Western European countries.


Getting Started...

Check out our Google Reviews

Overview

The EM Test UCS500N7 Multifunctional Transient Immunity Simulator includes everything necessary to conduct fully compliant tests at levels that go far beyond common test requirements.

Surge can be test up to 7.0kV either according to IEC/EN 61000-4-5 or ANSI/IEEE C62.41. The UCS 500N7 offers an integrated Ringwave module (optional) as per ANSI/IEEE C62.41 and IEC/EN 61000-4-12 for ringwave tests on mains supply lines.

The EM Test UCS 500N7 can be operated manually from the front panel or by remote via the built-in USB or GPIB interface. Fail inputs allow to control an ongoing test sequence based on the status of the DUT. Monitoring outputs (BNC) are offered for easy signal measurement and verification. Safety features such as interlock and warning lamp control are available.

Pre-programmed Standard Test routines allow highest user convenience. Still the UCS 500N7 offers the Quick Start test routine where parameters can be changed on-line during the test to evaluate the susceptibility level of an individual DUT, a most appreciated benefit for tests at development stage.

The EM Test UCS500N7 Multifunctional Transient Immunity Simulator is the most versatile tester to cover transient and power fail requirements according to international standards (basic and generic standards) and product/ product family standards with voltage capability of up to 7.0 kV. Apart from the IEC/EN 61000-4-5 standard for surge testing it also complies to ANSI/IEEE C62.41 for surge and ringwave testing.

The UCS 500N7 not only represents the most economic solution for full-compliant immunity tests and CE Marking but goes far beyond. Having a built-in CDN for single phase DUTs it can be extended for testing three-phase DUTs by means of an automatically controlled external coupling network up to 100A.

EM Test UCS500N7 Features:

  • Ultra-Compact Simulator up to 7.0kV
  • Surge Module for IEC/EN 61000-4-5 Edition 3
  • Burst Module for IEC/EN 61000-4-4
  • PowerFail Module for IEC/EN 61000-4-11
  • Ringwave Module for IEC/EN 61000-4-12 (optional)
  • Telecom Surge Module (IEC/EN 61000-4-5) optional
  • Magnetic field tests with optional accessories
  • Built-in single phase coupler 300V/16A
  • USB and GPIB-Bus for remote control
  • Manual operation from front panel
  • Monitor outputs for peak voltage and peak current
  • Fail inputs
  • External variac control 0-10Vdc
  • Control of external three-phase couplers

EM Test UCS500N7 Ordering Options:

  • UCS 500N7: Ultra compact simulator with EFT/N7, VCS/N7 and PFS/N7; 1ph CDN 300V AC/DC (p-n) / 16A (IEC & ANSI Cat.A & B)
  • UCS 500N7.1: Ultra compact simulator with EFT/N7, VCS/N7 and PFS/N7; 1ph CDN 300V AC/DC (p-n) / 32A (IEC & ANSI Cat.A & B)
  • UCS 500N7.2: Ultra compact simulator with EFT/N7, VCS/N7 and PFS/N7; 1ph CDN 400V AC/DC (p-n) / 16A (IEC & ANSI Cat.A & B) No module RWG/N7 possible with this unit!!!
  • UCS 500N7.3: Ultra compact simulator with EFT/N7, VCS/N7 and PFS/N7; 1ph CDN 300VAC (L-N) / 32A (ANSI), can have RWG/N7 installed, unit will become 9HU high. RWG/N7 module to be ordered additionally
  • UCS 500N7.4: Ultra compact simulator with EFT/N7, VCS/N7, RWGN/7 and PFS/N7; 1ph CDN 400V AC/DC (p-n) / 16A (IEC & ANSI Cat.A & B)
  • UCS 500N7.7: Ultra compact simulator with EFT/N7 and VCS/N7 (IEC & ANSI Cat.B coupling), without built-in coupler! Application Voltage 690V(p-p)

Videos

Key Considerations

Manufacturer:
EM Test
Test Capabilities:
Combination Wave Surge Immunity , EFT/Burst, Dips Interrupts & Variations
EMC Standards:
IEC 61000-4-5, IEC 61000-4-4, IEC 61000-4-11
Test Setup Guides:
Electrical Transient and Noise, Surge Immunity, Power Failures
EFT/Burst Pulse Output Capability:
±200 V to 4.8 kV (in 1 V steps) - open circuit±100 V to 2.4 kV ±100 A to 2.2 kA
Combination/Wave Surge Output Capability:
250 V - 6,000 V ± 10%
External Coupling:
Data Lines (EFT & Surge), 3PH EUT
Phase synchronization:
0° - 360°, resolution 1° (16 - 500Hz)
Ringwave 0.5 ÎĽs/100 kHz:
Pulse conforms to IEC/EN 61000-4-12 and ANSI (IEEE) C62.41
Telecom Surge:
As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendations