Amplifier Research emcware EMC Software

Manufacturer:
Amplifier Research
Online Orders Ship Same Day

 

SKU:
sku-1777

 

This product is available for shipping to North America and Western European countries.


Getting Started...

Check out our Google Reviews

Overview

Amplifier Research emcware EMC Software Suite Version 4.0

The Amplifier Research emcware® Suite by AR RF/Microwave Instrumentation provides automated Electromagnetic Compatibility (EMC) testing and report generation for all types of users from corporate to professional test laboratories. It is a standalone software application designed to operate on a PC running a Microsoft WindowsTM operating system. The export classification for this software is EAR99. This software is controlled for export in accordance with the U.S. Export Administration Regulations. Diversion contrary to U.S. law is prohibited.

Software Design

The Amplifier Research emcware® Suite is designed to be userfriendly yet extremely flexible. It is broken up into modules based on different types of EMC testing. Within each module there are predefined standards. The ability to create custom test standards is also provided.

Equipment Management

Contained within the Amplifier Research emcware® is a built-in Equipment List Manager. This tool allows for equipment to be entered one time and then accessed from within any of the modules. The Equipment List Manager also keeps track of calibration dates and can warn the user when the calibration date of a specific piece of equipment is approaching.

EUT Monitoring

Use custom equipment or a National Instruments DAQ card to monitor and report the status of the equipment under test (EUT). The National Instruments DAQ device can monitor Analog or Digital levels from the EUT or reset the EUT using the Digital Outputs. Custom equipment, in conjunction with dynamic link library (DLL) files, allows for complete EUT monitoring and control.

Instrument Drivers

Instrument control is provided through AR RF/ Microwave Instrumentation’s extensive driver library. Creation of new drivers for equipment that is not currently supported is available up on request. Drivers can also be created and imported by the user in the form of dynamic link libraries (DDL) files. For a list of supported remote interfaces, see the Equipment Interface section.

Signal Routing

The Amplifier Research emcware® is designed to allow the user to select between manual and automatic signal routing. Automatic signal routing is implemented using one or more AR RF/Microwave Instrumentation Model SC2000 System Controllers.

User Security Levels

Define equipment and test set-ups as a System Administrator, then change the security level to Restricted User to ensure secure testing.

Reports

Extensive report generation capability is built into each module. These reports can be customized by the user. All reports are created in Microsoft Word or Microsoft Excel.

Help Instructions

A detailed help utility is included with the emcware®. The contents of the help instructions can be searched by keyword or topic. Open the help file using the context-sensitive help buttons located throughout the user interface.

Software Licensing

The Amplifier Research emcware® is fully functional for a period of 60 days from the date of install. Registration is required to obtain a license for operation beyond 60 days.

AR Systems Compatibility

The Amplifier Research emcware® can automatically control select AR Systems using built-in equipment setups. See the Compatible Systems for a complete list.

Amplifier Research emcware Specifications

RECOMMENDED PC HARDWARE REQUIREMENTS:

  • Intel i5 or equivalent
  • 4 GB of RAM
  • Screen resolution 1,024 x 768 pixels and higher
  • 2 available USB (2.0) Ports

OPERATING ENVIRONMENTS:

  • Windows 10, Windows 7 Service Pack 1, Windows 8.1

SUPPORTED INTERFACE HARDWARE (Not Included):

  • National Instruments GPIB Controller
  • NI GPIB-USB-HS+ [AR P/N 10013688] or equivalent National Instruments device required for GPIB communications
  • National Instruments DAQ (Data Acquisition) device
  • NI USB-6212 [AR P/N 10025318] is recommended, but the configuration is customizable

SUPPORTED EQUIPMENT COMMUNICATIONS INTERFACES:

  • IEEE 488 (GPIB), National Instruments NI GPIB-USBHS+ [AR P/N 10013688] or equivalent device required
  • RS-232
  • USB
  • Ethernet (creation of a National Instruments VISA TCP/IP Resource required)

EQUIPMENT DRIVERS:

  • A full list of included equipment drivers can be found at the end of this document.
  • For equipment that is not currently supported, please contact the factory.
  • Equipment drivers can be written by the user in a multitude of programming languages (LabVIEW, Visual Studios, etc.) and imported as dynamic link library (DLL) files.
  • Equipment Driver Templates are included for LabVIEW and Visual C++
  • Includes demonstration drivers for all controllable equipment types to allow operation without equipment.

REPORTS:

  • Microsoft Word/Excel 2007 or newer required for all output formats
  • Output Formats
  • Microsoft Word / Excel
  • PDF
  • Included Data
  • All data collected in numerical & graphical formats
  • Test information (test standard, file paths, completion date, etc.)
  • User and Customer information (optional)
  • EUT monitoring data including Pass / Fail status and user comments
  • Test setup information (test level, frequencies, dwell times and EUT monitoring setup)
  • Equipment names and calibration dates
  • Basic equipment interconnect diagram

INCLUDED TEST STANDARDS, emcware®

Organization Standard Version RS CI RE CE
CISPR CISPR 11 Ed 5 ? ?
CISPR 13 Ed 4 ?
CISPR 22 Ed 6 ? ?
CISPR 25 Ed 2 ? ?
CISPR 32 Ed 1 ? ?
Department of Defense MIL-STD-461 RS103 D, E, F, G ?
MIL-STD-461 CS114 D, E, F, G ?
MIL-STD-461 RE(101, 102) D, E, F, G ?
MIL-STD-461 CE (101, 102) D, E, F, G ?
RTCA DO-160 Section 20 D, E, F, G ? ?
DO-160 Section 21 D, E, F ? ?
IEC 61000-4-3 Ed 3.1 ?
61000-4-6 Ed 4 ?
50130-4 1996 ? ?
60601-1-2 Ed 4 ? ?
61000-6-1 Ed 2 ? ?
61326 Ed 2 ? ?
61000-6-2 Ed 2 ?
Telcordia Technologies GR-1089-Core Issue 3, 6 ?
International Organization for Standards ISO-11452-(2, 3, 5) Ed 2 ?
ISO-11452-4 Ed 4 ?
Ford ES-XW7T-1A278-AC 10/10/2003 ? ?
GM GMW3097 04/2004 ? ?
BMW GS 95002 2004-10 ?
Chrysler DC-11224 2006-10 ?
Renault 36-00-808 2003 ?
Peugeot B21 7110 B ?


LEGEND: RS (Radiated Susceptibility), CI (Conducted Immunity), RE (Radiated Emissions, CE (Conducted Emissions)

INCLUDED EQUIPMENT DRIVERS
Field Probes/Monitors
AR RF/MICRO INSTR All Models Supported*
Field Probes/Monitors
AR RF/MICRO INSTR All Models Supported*
CHAUVIN ARNOUX CA43
HOLADAY INDUSTRIES HI-6105, HI-6100
NARDA EMC-20, NBM-520,
EMR-200, EP60x Series
Receivers
AR RF/MICRO INSTR All Models Supported*
AGILENT/HP MXE N9038A
ROHDE & SCHWARZ ESU, ESCI, ESPI, ESIB
System Controllers
AR RF/MICRO INSTR All Models Supported*
Spectrum Analyzers
AGILENT/HP ESA Series, PSA Series, N90x0A (CXA, EXA, MXA, PXA), E740Xa, 856x Series, 859x Series, 8542E, 8546A
RIGOL DSA8xx
ROHDE & SCHWARZ FSL, FSP
Antenna Controllers
SUNAR (formerly Sunol Sciences) SC98VA, SC110VA
EMCO 1050, 1090A, 2090A
ETS EMCenter (7006-001) (AUX)
Turntable Controllers
SUNAR (formerly Sunol Sciences) SC98VT, SC110VT
EMCO 1060, 1090T, 2090T
FRANKONIA FC06
ETS E MCenter(7006-001)
Probe Positioners
PROBOTIC SYSTEMS 801
TDK SI 300
Pulse Generators
AGILENT/HP 3325A, 33220A, 8116A, 81101A
Signal Generators
AR RF/MICRO INSTR All Models Supported*
AGILENT/HP DSO-X 3xxx Series, E8257C, E8257D, ESG, N517XB, N5183A, N9310A, 33120A, 33250A, 3336C, 8341, 8350B, 83620B, 83630B, 83731 8642B, 8642B, 8648, 8657A, 8657B, 8662A, 8663A, 8664A, 8673B
ANRITSU MG3694A
BERKLEY NUCLEONICS 845/835-6
FLUKE 6060A, 6061A, 6062A
GIGATRONICS 1018, 6080A, 12000A
HAMEG HM8134-3, HM8135
IFR 341x Series
MARCONI 2022, 2023, 2024, 2025, 2030, 2031, 2032
ROHDE & SCHWARZ SMB, SMBV100A, SME, SMF, SMG, SMH, SML, SMP, SMR, SMT, SMX, SMY
WILTRON 6668B, 6747A
ANAPICO APSINx000, 12G, 20G, 26G
RIGOL DSA8xx
Power Meters
AR RF/MICRO INSTR All Models Supported*
AGILENT/HP DSO-X 3xxx Series, EPM E44117, EPM E44118, EPM E44119, EPM 441x, EPM 441A, EPM E442, N1913A, N1914A 436A, 437B, 438A
BIRD 4421
BOONTON 4230, 9200, BI 55xx
DARE RPR1004A, RPR1006A, RPR1018A
MARCONI 6960
ROHDE & SCHWARZ NRP, NRVS, NRVD, URV5
TESEQ PM6003


*NOTE: AR models created after the current release of the software may not be fully supported, but will be supported in subsequent releases within the scope of the emcware® software

Key Considerations

Manufacturer:
Amplifier Research

Connect with The EMC Shop

Our experienced staff can help you with applications, purchase and rental options.