Overview

Filters for power supply lines are measured according to CISPR 17, annex C (respectively DIN EN 55017, annex C).

Two wideband transformers are required to transform the typical impedance of measurement devices from 50 ? to 0.1 ? or from 50 ? to 100 ? respectively.

The 0.1 ? transformer (voltage division ratio 22:1) has to be connected to the 50 ? generator. The 100 ? transformer (voltage division ratio 1.4:1) has to be connected to a 50 ? receiver. The schematic below shows how to set up the measurement.

IMPORTANT! Do NOT connect the transformers to any kind of power supply, neither A.C. nor D.C.

Specifications
Model SY 9223-17-0.1 SY 9223-17-100
Nominal frequency range 1 kHz – 300 kHz 1 kHz – 300 kHz
Return loss min. 15 dB min. 15 dB
Max. power dissipation 500 mW 500 mW
Impedance transformation 50 ? : 0.1 ? 100 ? : 50 ?
Dimensions incl. connectors L= 105 mm, H= 43 mm, B= 40 mm L= 105 mm, H= 43 mm, B= 40 mm
Weight max. 300 g max. 250 g
Connector 50 ? side 50 ? BNC Buchse/female 50 ? BNC Buchse/female
Connector 100 ? side 4 mm Buchsen/4 mm female 4 mm Buchsen/4 mm connector


Transmission of the two transformers measured in the 50? System (back to back)