Coupling Decoupling Networks (CDN's) Categories
Coupling Decoupling Networks (CDN's) Test Equipment, Systems & Solutions
-
3ctest CDN 418TH8 CDN For Unshielded Symmetric High-Speed
SKU: sku-1116
Communication Frequency: 10 MHz, 100 MHz, 1000 MHz, 10 MB, 100 MB, 1000 MBStandard Met: IEC 61000-4-8Pulse Voltage: 4 kVCoupling Mode: 4-pair unshielded symmetricConnector: RJ45 female connectorTypically In Stock -
-
-
Teseq (Schaffner) CDN 163 3-Phase, 100 Amp EFT/Burst Coupling Network
SKU: 1064
Applications: Electrical Fast Transient ImmunityTest Standards: IEC/EN 61000-4-4Industry: EMC Precompliance Testing, CE Marking, Medical Devices, Industrial Machinery, Electronics & ITFor Use With: Any Burst/EFT GeneratorTypically In Stock -
Teseq CDN S900S RS-232 Coupling Decoupling Network for IEC 61000-4-6
SKU: 10828
Weight: 1.5 kg (3.3 lbs)Application/Test Type: Coupling / decoupling network (CDN) for screened data/telcom lines or coaxial cablesCommon Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 ΩCurrent Rating: 250 mA (CDN ST08 1 Amp)Decoupling of Common Mode Disturbance: 150 kHz: Over 60 dB; 1.5 MHz: Over 60 dB; 30 MHz: Over 50 dB; 230 MHz: Over 40 dB (refer to data sheet for some exceptions)Dimensions: 4 x 4 x 9.5 inches (10 cm x 10 cm x 24 cm); (CDN HDMI and CDN S752A: 28.8 cm 11 inches)Frequency Range: 10 kHz to 80 MHz or 150 kHz to 230 MHzMains & EUT Connections: BNC 50 Ω, N 50 Ω, BNC 75 Ω, N 75 Ω, XLR 3 pins, DIN 5 pins, RJ45, D-Sub 9 pins, D-Sub 15 pins, D-Sub 25 pins, HDMI (refer to data sheet for exact model specifications)RF Connector: BNC 50 ΩRF Input Voltage: 20 Volts MaxStandards Met: IEC 61000-4-6, CISPR 22, IEC 60601-1-2Voltage Division Factor: 9.5 dB to 10 dB ±1 dB (refer to data sheet for some exceptions)Voltage Rating: AC max. voltage (line to ground): 100 V - 250V; DC max. voltage (line to ground): 150 V - 400 V; Test voltage: 200 V - 750 V DC, 2 sec (refer to data sheet for exact model specifications)$1,190.00 -
Teseq CDN M016 Switchable 16 Amp Coupling/Decoupling Network
SKU: 10827
Associated Equipment: RF Conducted Immunity Test SystemsApplication/Test Type: switchable 2 or 3 power lines, (L+N or L+N+PE)Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 ΩCurrent Rating: 16 AmpsDecoupling of Common Mode Disturbance: 150 kHz: Greater than 30 dB 1.5 MHz: Greater than 60 dB 30 MHz: Greater than 40 dB 230 MHz: Greater than 20 dBDimensions: 3.9" x 3.9" x 9.5" (100 mm x 100 mm x 240 mm)Frequency Range: 150 kHz to 230 MHzInsertion Loss: Less than 0.1 dBMains & EUT Connections: 4 mm bananaRF Connector: BNC 50 ΩRF Input Voltage: 30 Volts (Max)Standards Met: IEC/EN 61000-4-6Voltage Division Factor: 150 kHz to 80 MHz: 9.5 dB ±1 dB 80 MHz to 230 MHz: 9.5 dB +3 dB / -2 dBVoltage Rating: AC max. voltage (line to ground): 250 V DC max. voltage (line to ground): 400 V; 3 kV DC, 2 sec$195.00 - $495.00Typically In Stock -
Schloder M Type CDN's for Disturbance Signals to Unscreened Supply Lines (mains) AC + DC up to 1000V, 100A
SKU: sku-791
Application/Test Type: unscreened supply lines (mains) AC + DCCurrent Rating: 16A / 32A / 63 A / 100 ADimensions: 160 x 84,5 x 240mm or 200 x 122,5 x 400mm depending on modelFrequency Range: 150 kHz to 230 MHzMains & EUT Connections: banana socketsRF Connector: 50 Ω BNC (Female)Standards Met: IEC / EN 61000-4-6Voltage Rating: up to 250 VAC / 400 VDC -
EFT-DLC EFT/Burst Capacitive Coupling Clamp for Data Lines
SKU: 1780
Application/Test Type: Electrical Fast Transients on Data Lines (EFT Burst)Built in Accordance to: IEC 61000-4-4Coupling Length: 1 m (39.4 in)Compatible Impulse Generators: Any EFT/Burst Generators (custom HV cable may be required)RF Connector: Fischer HV ConnectorVoltage Rating: up to 5.0 kV$195.00 - $2,495.00In Stock -
Fischer Custom Communications FCC-801-M3-16A, 3 Line M Series CDN, 150 kHz – 230MHz, 16 Amp
SKU: sku-731
Application/Test Type: 3 Power ConductorsCommon Mode Impedance: Frequency dependent 150 kHz – 26MHz: 150Ω ±20Ω 26MHz – 80MHz: 150Ω +60Ω -45Ω 80MHz –230MHz: 150Ω +60Ω -60ΩCurrent Rating: 16 AmpsFrequency Range: 150 kHz to 230 MHzMains & EUT Connections: Multi-Contact Safety SocketRF Connector: 50 Ω BNC (Female)RF Input Voltage: 30 VoltsStandards Met: IEC / EN 61000-4-6Voltage Division Factor: 10dB+1dB/-3dBVoltage Rating: DC less than 600V, AC less than 250V -
Dressler S1 Coupling/Decoupling Networks (CDN) 150 kHz-230 MHz
SKU: sku-399
Weight: 1.9 Lbs (0.86 kg)Application/Test Type: For coupling and decoupling of interference signals on screened linesCurrent Rating: 1.5 AmpsDimensions: 7.25 x 4.25 x 5.75 (inches)Frequency Range: 150 kHz to 230 MHzMains & EUT Connections: BNCStandards Met: IEC/EN 61000-4-6Voltage Rating: 100 V -
Teseq CDN 118-T4 Coupling Decoupling Network set for 1.2/50 µs and 10/700 µs Surge Pulses on 1 or 2 twisted pairs
SKU: 30093
Application/Test Type: 1.2/50 μs (2 ohms) and 10/700 μs (15 ohms) pulse up to 6.6 kV line to ground, 3 kV line to line (Pulse frequency: 3 per minute)Current Rating: 0.5 AmpsDecoupling chokes 1 kHz: 20 mH nominalDimensions: 335 x 232 x 180mmMains & EUT Connections: 4 mm safety banana; Fischer 103Ohmic resistance per path: 3 ΩSeries resistor: in relation to the selected pulse coupling networkTransmission 3 dB BW: 250 kHzVoltage Rating: 250 Volts AC/DCInquire for Lead Time -
3ctest 405T8A1 Surge CDN For Unshielded Data Lines
SKU: sku-332
Application/Test Type: Test high-speed communication lines against lightening surge as per picture 10 in IEC/EN61000-4-5 edition 3Coupling: Common mode (line to ground)l 90V gas discharging tubeCurrent Rating: Max 1 AImpedance: 200Ω ±5%Input: 1.2/50us, 10/700usMains & EUT Connections: RJ45 femaleStandards Met: IEC 61000-4-5 Ed. 3Test Voltage: 6kV (10kV, customized)Voltage Rating: 90 VDCTypically In Stock