Conducted Immunity

(Showing 12 of 166)
Show 12 24 36 48 96

Conducted Immunity Categories

Conducted Immunity Test Equipment, Systems & Solutions

  • 3ctest CWS 800 8kV Surge Combination Wave Simulator for IEC/EN 61000-4-5 up to 8 kV

    SKU: sku-797

    Weight: Approx 30 kg (66 lbs)
    Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5
    Coupling: Single Phase Built in, 16A, 250VAC, 120VDC
    Dimensions: 19 inch/6u
    Impedance: 2 Ohm
    Mains & EUT Connections: 4mm banana plug
    Phase synchronization: 0°-360°, 1°step or random
    Polarity: Positive, Negative, Alternate
    Pulse current (short circuit): 0.1kA-3kA ±10%
    Pulse repetition: 1-999
    Pulse voltage (open circuit): 0.2kV - 8kV ±10%
    Standards Met: IEC 61000-4-5, UL1449 and more
  • EMC Partner CDN-KIT1000 ED3

    SKU: 35425

    Standard: IEC 61000-4-5
    Application: surge on 2 unsymmetrical lines
    Test level surge: max. 6 kV
    EUT voltage per line: max. 200 V DC or 240 V peak
    EUT current per line: max. 4 A cont. or 5 A for 5 min.
    Typically In Stock
  • EM Test OCS 500N6F Simulator for Fast/Slow Damped Oscillatory Waves and Ringwave

    SKU: 10413

    Burst duration: 50 ms ±20%, at 3 MHz 15 ms ±20%, at 10 MHz 5 ms ±20%, at 30 MHz
    Damping Rate: Peak 5 to be more than 50% of peak 1 value Peak 10 to be less than 50% of peak 1 value
    Oscillation Frequency: 3 MHz, 10 MHz and 30 MHz, ±10%
    Source Impedance: 50 ohm ±20%
    Voltage: Voltage (o.c.) at HV output 450 V - 4,400 V ±10%
    Burst Duration: At least 2s
    Damping Rate-2: Peak 5 to be more than 50% of peak 1 value Peak 10 to be less than 50% of peak 1 value
    Fast Damped Oscillatory Waves: As Per EN/IEC 61000-4-18
    Frequency: 100 kHz ± 10%
    General Data: Technical Details
    Impedance: 12ohm and 30ohm ± 20%
    Oscillation Frequency-2: 100kHz and 1MHz ± 10%
    Peak current: Max. 500A @ 12ohm or Max. 200A @ 30ohm internally;
    Polarity-2: Positive, negative
    Pulse repetition: 1 to 60 transients per minute
    Repetition Rate: Max. 5,000 /s ±10%
    Ringwave 0.5 μs/100 kHz: Pulse conforms to IEC/EN 61000-4-12 and ANSI (IEEE) C62.41
    Source impedance: 200ohm ± 20%
    Spike frequency: 100kHz ± 10%
    Test Voltage: 250 V - 6,000 V ± 10%
    Inquire
  • 3ctest SG 5010H 10kV Surge Simulator for IEC 61000-4-5, GB/T, ITU-T K21/K44

    SKU: sku-326

    Polarity: +/-, positive first or negative first
    Weight: Approximately 300 kg
    Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5
    Coupling: 1 or 3 Phase 16 Amps 250V/450V
    Impedance: 500Ω±10%
    Input voltage UIN: AC220V±10%,50/60H
    Output Current: 10/700 and 5/320±20%μs
    Polarity-2: +/-, positive first or alternate
    Pulse current (short circuit): 150A - 3kA/5kA (±10%)
    Pulse voltage (open circuit): 300V - 6kV/10kV (±10%)
    Standards Met: EN/IEC 61000-4-5, IEC 61643-1, GB/T 17626.5m GB/T 16927.1, ITU-T K21 and ITU-T K44
    Telecom Surge: As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendations
    Test duration: Voltage - 50μs(±20%); Current - 20μs(±20%)
    Test Voltage: 300V~6Kv/10kV (±10%)
    Transfer Impedance: 15Ω、40Ω(25+15Ω
  • 3ctest EFT 700 Burst/EFT Simulator up to 7 kV with Single or Three Phase CDN

    SKU: sku-566

    Test Capabilities: EFT Immunity, Medical Devices
    Standards Met: IEC/EN 61000-4-4
    Applications: CE Marking, Medical Devices, Industrial Machinery, Electronics & IT
    Max EUT AC Voltage (w/ Built in CDN): 250 Volts (380V w/ 3PH CDN)
    Max EUT AC Current (w/ Built in CDN): 16 Amps
    Max EUT DC Voltage (w/ Built in CDN): 220 Volts
    Max EUT DC Current (w/ Built in CDN): 16 Amps
    EFT/Burst Pulse Output Capability: 7 kV
    External Coupling: Data Lines
  • EM Test ESD NX30 Electrostatic Discharge Simulator Gun System for up to 30kV Testing

    SKU: 7395

    Weight: 6.5 kg (Base Station) 1,250 g (discharge gun)
    Voltage Range: 200 V - 30,000 V ± 5 %
    Test Standards: ISO 10605, IEC 61000-4-2
    Holding Time: More than 5 sec
    Applications: EV and Automotive
    Polarity: Pos / Neg
    Pre-Programmed IEC Levels: Yes
    Resolution: 100 V steps
    Additional Test Standards: IEC 60601-1-2, MIL-STD-461 CS118, RTCA DO-160
    $990.00 - $17,500.00
    1 In Stock
  • 3ctest SG3483 Multiple Waveform Lightning Surge Simulator for IEC 61000-4-5

    SKU: sku-605

    Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5
    Counter: unlimited
    Output: Output waveform 1, 2, 3: 2kV - 20kV
    Polarity: pos / neg / alternate
    Pulse current (short circuit): 2kV ±10%@50A ±10% 6kV ±10%@150A ±10% 10kV ±10%@250A ±10% 15kV ±10%@375A ±10% 20kV ±10%@500A ±10%
    Pulse repetition: automatic 2 s – 100 min (Manual and external triggering available)
    Pulse voltage (open circuit): 2kV ±10% 6kV ±10% 2kV ±10% 10kV ±10% 15kV ±10% 20kV ±10%
    Standards Met: IEC 61000-4-5
    Supply Voltage: 220V(±10%)/50Hz
  • 3ctest CWS 1000N 10kV Surge Generator for IEC/EN 61000-4-5

    SKU: sku-798

    Weight: Approx 44 kg (97 lbs)
    Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5
    Dimensions: 19 inch/6u
    Impedance: 2 Ohm
    Phase synchronization: 0°-360°, 1°step or random
    Polarity: Positive, Negative, Alternate
    Pulse current (short circuit): 0.1kA-5kA ±10%
    Pulse voltage (open circuit): 0.2kV - 10kV ±10%
    Standards Met: IEC 61000-4-5