Wavecontrol WPF90 Field Probe 30 MHz – 90 GHz

Manufacturer:
Wavecontrol
  • Electric field measurement
  • Isotropic & True RMS measurement
  • Excellent attenuation at 50/60 Hz
  • Measurements in accordance with International Standards
Frequency Range:
30 MHz - 90 GHz
Sensor Type:
Isotropic RMS diode technology
Measurement range:
1.2 – 1000 V/m (CW) 1.2 – 70 V/m (RMS)
Dynamic range:
58 dB
Sensitivity:
1.2 V/m
Integration time:
500 ms
Linearity:
± 1 dB (2 – 250 V/m)
Damage level (CW):
1200 V/m
Calibration:
ISO 17025 Accredited Calibration (ILAC
Calibration period:
24 months (recommended)
Temperature range:
- 20 ºC to 50 ºC
Temperature response:
+ 0.1 / - 1 dB (related to 20 ºC)
Dimensions:
28.4 cm x 6 cm Ø
Attenuation at 50/60 Hz:
> 40 dB
Isotropic Deviation:
± 1 dB (< 12 GHz) ± 2 dB (12 GHz to 60 GHz) ± 3.5 dB (60 GHz to 90 GHz)
Frequency response (*):
± 3 dB (30 MHz – 50 GHz) ± 1/-6 dB (50 GHz – 60 GHz) 0/-10 dB (60 GHz – 90 GHz)
Weight:
95 g

 

No reviews yet Write a Review
Availability:

In Stock

SKU:
2511252

 

 

Due to tariff increases, some items in our catalog are subject to additional costs when purchased.


Getting Started...

Check out our Google Reviews

Overview

The Wavecontrol WPF90 redefines industry standards by delivering exceptional performance across a wide frequency range (30 MHz – 90 GHz). Its isotropic sensor, ensures accurate and reliable measurements in any environment.

Applications:

  • Telecommunications
  • Wireless telecom networks: IEC 62232, EN 50400, EN 50401
  • Broadcast: IEC 6251237, EN 50475, EN 50476, EN 50496, EN 50554
  • Satellite installations
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
  • Microwave drying
  • Detection of leaks
  • Radar
  • Defense (HF)

Key Considerations

Manufacturer:
Wavecontrol
Frequency Range:
30 MHz - 90 GHz
Sensor Type:
Isotropic RMS diode technology
Measurement range:
1.2 – 1000 V/m (CW) 1.2 – 70 V/m (RMS)
Dynamic range:
58 dB
Sensitivity:
1.2 V/m
Integration time:
500 ms
Linearity:
± 1 dB (2 – 250 V/m)
Damage level (CW):
1200 V/m
Calibration:
ISO 17025 Accredited Calibration (ILAC
Calibration period:
24 months (recommended)
Temperature range:
- 20 ºC to 50 ºC
Temperature response:
+ 0.1 / - 1 dB (related to 20 ºC)
Dimensions:
28.4 cm x 6 cm Ø
Attenuation at 50/60 Hz:
> 40 dB
Isotropic Deviation:
± 1 dB (< 12 GHz) ± 2 dB (12 GHz to 60 GHz) ± 3.5 dB (60 GHz to 90 GHz)
Frequency response (*):
± 3 dB (30 MHz – 50 GHz) ± 1/-6 dB (50 GHz – 60 GHz) 0/-10 dB (60 GHz – 90 GHz)
Weight:
95 g