Wavecontrol WPF90 Field Probe 30 MHz – 90 GHz

SKU:
2511252
Availability:
In Stock
Manufacturer:
Wavecontrol
  • Electric field measurement
  • Isotropic & True RMS measurement
  • Excellent attenuation at 50/60 Hz
  • Measurements in accordance with International Standards
Frequency Range:
30 MHz - 90 GHz
Sensor Type:
Isotropic RMS diode technology
Measurement range:
1.2 – 1000 V/m (CW) 1.2 – 70 V/m (RMS)
Dynamic range:
58 dB
Sensitivity:
1.2 V/m
Integration time:
500 ms
Linearity:
± 1 dB (2 – 250 V/m)
Damage level (CW):
1200 V/m
Calibration:
ISO 17025 Accredited Calibration (ILAC
Calibration period:
24 months (recommended)
Temperature range:
- 20 ºC to 50 ºC
Temperature response:
+ 0.1 / - 1 dB (related to 20 ºC)
Dimensions:
28.4 cm x 6 cm Ø
Attenuation at 50/60 Hz:
> 40 dB
Isotropic Deviation:
± 1 dB (< 12 GHz) ± 2 dB (12 GHz to 60 GHz) ± 3.5 dB (60 GHz to 90 GHz)
Frequency response (*):
± 3 dB (30 MHz – 50 GHz) ± 1/-6 dB (50 GHz – 60 GHz) 0/-10 dB (60 GHz – 90 GHz)
Weight:
95 g
No reviews yet Write a Review

Due to tariff increases, some items in our catalog are subject to additional costs when purchased.

Overview

The Wavecontrol WPF90 redefines industry standards by delivering exceptional performance across a wide frequency range (30 MHz – 90 GHz). Its isotropic sensor, ensures accurate and reliable measurements in any environment.

Applications:

  • Telecommunications
  • Wireless telecom networks: IEC 62232, EN 50400, EN 50401
  • Broadcast: IEC 6251237, EN 50475, EN 50476, EN 50496, EN 50554
  • Satellite installations
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
  • Microwave drying
  • Detection of leaks
  • Radar
  • Defense (HF)

Downloads

Key Considerations

Manufacturer:
Wavecontrol
Frequency Range:
30 MHz - 90 GHz
Sensor Type:
Isotropic RMS diode technology
Measurement range:
1.2 – 1000 V/m (CW) 1.2 – 70 V/m (RMS)
Dynamic range:
58 dB
Sensitivity:
1.2 V/m
Integration time:
500 ms
Linearity:
± 1 dB (2 – 250 V/m)
Damage level (CW):
1200 V/m
Calibration:
ISO 17025 Accredited Calibration (ILAC
Calibration period:
24 months (recommended)
Temperature range:
- 20 ºC to 50 ºC
Temperature response:
+ 0.1 / - 1 dB (related to 20 ºC)
Dimensions:
28.4 cm x 6 cm Ø
Attenuation at 50/60 Hz:
> 40 dB
Isotropic Deviation:
± 1 dB (< 12 GHz) ± 2 dB (12 GHz to 60 GHz) ± 3.5 dB (60 GHz to 90 GHz)
Frequency response (*):
± 3 dB (30 MHz – 50 GHz) ± 1/-6 dB (50 GHz – 60 GHz) 0/-10 dB (60 GHz – 90 GHz)
Weight:
95 g