3ctest ISS 1800 Induced Signal Susceptibility Test System

Condition:
New

No reviews yet Write a Review
Test Standards:
DO-160 Section 19
Open-circuit Voltage:
1,800 Volts
Short-circuit Current:
40 Amps
Frequency Range:
350 Hz to 32 kHz
Electric Fields Induced into the Equipment:
170 Vrms
Electric Field Induced into Interconnecting Cables:
135 V/m to 5400 V/m
Magnetic Fields Induced into the Equipment:
20 Amps
Magnetic Fields Induced into Interconnecting Cables:
1.6 A/m to 120 A/m
Manufacturer:
3ctest

 

Availability:

Inquire for Availability

SKU:
35125

 


Getting Started...

Check out our Google Reviews

Overview

The 3ctest ISS 1800 induced susceptibility testing system is capable of generating alternating signals with frequency ranging from 350 Hz to 32 kHz, its voltage reaches up to 1800 V and maximum current is 40 A. The system conforms to the test requirement of Section 19 in RTCA DO160G and is made up of signal power amplifier, high voltage wide-band transformer, wide-band current transformer, high-precision digital multimeter and CoreLab testing software etc., It can be widely used in susceptibility tests of airborne equipment and other electrical devices. 

Rent, buy or lease the 3ctest ISS 1800 Induced Signal Susceptibility Test System. The EMC Shop is a preferred North American vendor for avionic and aerospace compliance testing on sub assemblies.
 
Features:
> Capable of obtaining transfer function automatically configured by the test system through self-check, greatly improving the accuracy of tests.
> With voltage and current monitor port, parameters of induced signals applied can be monitored on line. 
> The electric/magnetic fields radiator and radiating wiring designed in accordance with standard requirement make the test setup easy and greatly improve the test effectiveness and repetition.


System Includes:

1.     Signal Power Amplifier

ISG 1800, DCP 1800

2.     HV Wide-band Transformer 

HWT 1800 (1800 V)

3.     Wide-band Current Transformer

WCT 40 (40 A)

4.     Current-limiting Resistor   

CLR 1M (1 MΩ)

5.     Electric Fields Radiator 

ERB 20 (20 cm Length)

6.     Magnetic Fields Radiator

HRB 60 (60 cm Length)

7.     electric fields radiating wiring

ERL 5M (500 cm Length)

8.     magnetic fields radiating wiring

HRL 5M (500 cm Length)

9.     Digital Multimeter

34461A

Key Considerations

Manufacturer:
3ctest
Test Standards:
DO-160 Section 19
Open-circuit Voltage:
1,800 Volts
Short-circuit Current:
40 Amps
Frequency Range:
350 Hz to 32 kHz
Electric Fields Induced into the Equipment:
170 Vrms
Electric Field Induced into Interconnecting Cables:
135 V/m to 5400 V/m
Magnetic Fields Induced into the Equipment:
20 Amps
Magnetic Fields Induced into Interconnecting Cables:
1.6 A/m to 120 A/m