The EMC Shop has technicians well familiar with Ametek CTS equipment. Contact us for rentals, repairs, calibrations or refurbishment services.
Ametek CTS Categories
Ametek CTS Test Equipment, Systems & Solutions
-
-
-
Amplifier Research 10W1000C 10 Watt 500 KHz - 1 GHz RF Power Amplifier
SKU: 11153
Max Frequency: 1 GHzMin Frequency: 500 kHzOutput Power: 10 WattsApplications: Radiated Immunity, Automotive, Medical, Military and AerospaceStandards: IEC 61000-4-3, ISO 11451-2, MIL-STD 461, DO-160Gain: 40dBAC Input Power: 90-132V/1PH/300VACooling: Forced AirCost New:$15,200.00$7,950.00In Stock -
Amplifier Research ATH800M6G 800 MHz to 6 GHz High Gain Horn Antenna
SKU: 11083
Gain: 11 dBiMax RF Input Power: 1500 WattsApplications: Radiated Immunity, Automotive EV EMC TestingStandards: IEC 61000-4-3,FMC 1278, GMW3097Max Frequency: 6 GHzMin Frequency: 800 MHzTypically In Stock -
EM Test NX7 Multifunctional Test Generator For Transients
SKU: 30141
Test Capabilities: Combination Wave Surge Immunity , EFT/Burst, Dips Interrupts, Ring WaveStandards Met: IEC/EN 61000-4-4, IEC/EN 61000-4-5, IEC/EN 61000-4-11, IEC/EN 61000-4-12 IEC/EN 61000-4-29, ANSI/IEEE C62.4Applications: CE Marking, Medical Devices, Industrial Machinery, Electronics & ITMax EUT AC Voltage (w/ Built in CDN): 300 VoltsMax EUT AC Current (w/ Built in CDN): 16 AmpsMax EUT DC Voltage (w/ Built in CDN): 300 VoltsMax EUT DC Current (w/ Built in CDN): 16 AmpsEFT/Burst Pulse Output Capability: 5.5 kVCombination/Wave Surge Output Capability: 7 kVDips & Interrupts: 0, 40, 70, 80%Ring Wave: 7 kV / 100 kHzExternal Coupling: 3PH up to 200 Amps / Data LinesINQUIRE -
Amplifier Research PL7004 800MHz - 3.6GHz Electric Field Pulse Laser Powered Probe
SKU: 11935
Amplitude Accuracy: Without correction factors applied: ±1.5 dB @ 1 GHz; With correction factors applied: Typical expanded measurement uncertainty (95% confidence interval), 0.8 dB, 800 MHz–1 GHz; 1.4 dB, 1GHz–3.6 GHzDamage Level: 1000 V/m, Continuous Field or Pulsed FieldFrequency Range: 800MHz - 3.6GHzIsotropic Deviation: ±1.0 dB @ 1 GHz. For improved accuracy, this probe should be used with a single axis aligned with the E-field being measured.Operating Range: 80–800 V/mPulse Duration: 0.02% to 2%Pulse Period: Up to 5 milliseconds between pulses (greater than 200 Hz pulse rate)Pulse Width: 1 to 100 MicrosecondsRelative Flatness: ±2.5 dB, 800 MHz-3 GHz; ±3.0 dB, 3.0GHz 3.6GHzTemperature Stability: +0.5 dB Over Operating Temperature RangeInquire for Availability -
Amplifier Research FL7030 5 kHz - 30 MHz Electric Field Laser Powered Probe
SKU: 11934
Weight: 62.5 g (2.2 oz)Accuracy: ±1.0dB @ 10MHz1 0.8dB, 100kHz–1GHz3,4 1.4dB, 1GHz–6GHz3,4Analog Response Time: 20 msec/up to 50 samples per second, at FI7000 USB and GPIB interfacesCalibration Data: Accredited Calibration Report (A2LA) supplied with probeDamage Level: 1000 V/m continuous fieldData Returned From Probe: X, Y, Z axes, and CompositeDimensions: 5.7 x 5.7 x 5.7 cm (2.25 x 2.25 x 2.25 in) 2.92 cm (1.15 in) DIA spherical housing 3.18 cm (1.25 in) sensor radome per axesFiber Optic Connectors: Two E2000 compact duplex connectors at 1 meter, includes fiber optic verification loop.Isotropic Deviation: ± 0.5 dB @ 10 MHz ± 0.5 dB, 5 kHz–30 MHz (typical)Linearity: ± 0.5 dB and ± 0.9 V/mOperating Range: 1.5–300 V/mOperating Temperature: 10˚C to 40˚C (50˚F to 104˚F) @ 5% to 95% RH non-condensingPower Requirements: Laser powered from FI7000 interfaceRise time: Typical Analog 300nSTemperature Stability: ± 0.5 dB over operating temperature range -
Amplifier Research FA7006 6 GHz E-Field Probe Kit
SKU: 11933
Test Standards: IEC 61000-4-3Accuracy: ±1.0dB @ 10MHz1 0.8dB, 100kHz–1GHz3,4 1.4dB, 1GHz–6GHz3,4Damage Level: 1000 V/mDimensions: 5.7 x 5.7 x 5.7cmLinearity: ±0.5dBMinimum Pulse Width: 2μsOperating Range: 9 – 900V/mRise time: Typical Analog 300nSTemperature Stability: ±1.0dB, 10°C - 40°C8Typically In Stock -
Amplifier Research CL-105/CL-106 Shielded Enclosure Leak Detector System
Weight: 26 lbFrequency Range: 95 kHz (Crystal Controlled)Output Signal: Pulse modulated at approximately 600 Hz and has a 50% duty cycleReceiver: Two meter scales for high and low operation Aural output for headphone operation Battery operated for portable use Dynamic range of 120dBTransmitter Output: 1 Ampere RMS into an inductive load from approximately 5–50 μHy -
Amplifier Research ATR26M250 26–250 MHz Log-Periodic Antenna
SKU: sku-928
Weight: 31.8 kg (70 lb)Beamwidth: See graph - DataSheetDimensions: 279.4 x 53.6 x 202.4 cm (110 x 21.1 x 79.7 in)Frequency Range: 26–250 MHzGain: 6 dB (80–250 MHz) -3 to +6 dB (26–80 MHz)Impedance: 50 ohms nominalInput: 15000 WattsInput VSWR: 3.0:1 (80–250 MHz) 10:1 (26–80 MHz) -
-