RF Field Strength Meters Categories
RF Field Strength Meters
-
Wavecontrol SMP3 RF Field Meter
SKU: 8899
Frequency Range: DC to 60 GHzBattery Life: >24 HoursReadout Values: Total field (instantaneous, max., min. and average) Field components (X, Y, Z)Measurement Range: 0.2 - 1000 V/mHigh Pass Filters: 1 Hz, 10 Hz, 25 Hz and 100 HzTypically In Stock -
Narda NBM-520 Broadband Field Meter & 3 GHz Probe
SKU: 6278
Measurement Units: V/m, A/m, mW/cm² or W/m², % for shaped probesBattery Life: 20 hoursRecharging Time: 2 hoursPC Interface: Fiber Optic via USB (6 ft cable)Software: NBM-TS standard (Drivers for Tile, EMCWare, EMC32 and more available)$3,950.00 - $4,150.00In Stock -
Narda FieldMan 0 Hz to 90 GHz All-in-One Electromagnetic Field Meter
SKU: 12955
Frequency Range: 0 Hz/1 Hz/100 kHz to 90 GHzLogging Info: Temperature, Humidity, Air Preassure, Geolocation, Distance to GroundElectric Field Units: V/m, mW/cm2 , W/m2 , % of standard (depending on the connected probe)Magnetic Field Units: A/m, Tesla, Gauss, mW/cm2 , W/m2 , % of standard (depending on the connected probe)Compliance Standards: 2013/35/EU, IEC/EN 62311, ICNIRP 1998, ICNIRP 2010, IEC/EN 62233, GB-8702-2014, EMFV 2016$495.00 - $1,850.00Typically In Stock -
Wavecontrol SMP2 Broadband Field Strength Meter
SKU: 7056
Weight: 10.6 oz.Application/Test Type: Monitoring electric field strengths in GTEM's, Anechoic Chambers and other RF rooms for radiated immunity testing.Battery: NiMH rechargeable batteries 4 x AA size (Mignon), 2500 mAhDimensions: 1.5 x 2.0 x 8 inchesFrequency Range: 100 kHz - 60 GHzIN STOCK -
Narda NIM-511 Electric and Magnetic Field Meter
SKU: 856
Frequency Range: 100 kHz to 100 MHzElectric Field Measurement Range: 0.1 to 100 mW/cm2 (20 to 614 V/m)Magnetic Field Measurement Range: 0.2 to 200 mW/cm2 (0.073 to 2.3 A/m)Inquire for Availability -
Lumiloop E-Field Probe Kit Rental
SKU: 51903-1
Application/Test Type: Radiated ImmunityField Strength Range: <1 V/m to >1.000 V/mFrequency Range: 9 kHz to 18 GHz (26.5 GHz)Resolution: 0.05 Volts per meterTest Standards: MIL-STD 461 RS103, DO-160Typically In Stock -
Amplifier Research FL8018 Isotropic Field Probe, CW and Pulse, 18 GHz
SKU: 11018
Frequency Range: 20 MHz - 18 GHzMeasurement Type: CW, AM & PulseField Strength Range: 2 – 1000 V/mDynamic Range: >54 dBIsotropic Deviation (Measured at Ortho Angle): ±0.5 dB @ 100 MHzInquire for Availability -
Wavecontrol WPF90 Field Probe 30 MHz – 90 GHz
SKU: 2511252
- Electric field measurement
- Isotropic & True RMS measurement
- Excellent attenuation at 50/60 Hz
- Measurements in accordance with International Standards
Frequency Range: 30 MHz - 90 GHzIn Stock -
Narda EFD-5091 50 GHz E-Field Probe
SKU: 84851
Measurement Range: 8 to 614 V/m (True RMS)Frequency Range: 300 MHz to 50 GHzSampling Rate: 5 Hz / 270 msIsotropic Deviation: ±1 dB (0.6 GHz to 8 GHz), ±1.4 dB (8 GHz to 45.5 GHz)In Stock -
Narda EFD-9091 E-Field Probe 100 MHz to 90 GHz
SKU: 8485
Measurement Range: 0.5 to 400 V/m (CW), Typ. 0.5 to 61.4 V/m (True RMS)Dynamic Range: 58 dB (nominal)Flatness: ±3 dB (300 MHz to 40 GHz), +3/-6 dB (100 MHz to 60 GHz)Isotropic Deviation: ±1.25 dB (100 MHz to 10 GHz), ±2 dB (>10 GHz to 26.5 GHz)Applications: Radio link, telecommunications, satellite, and radarIn Stock -
Narda EFD-1891 E-Field Probe 2 MHz - 18 GHz
SKU: 7202
Measurement Range: 0.6 to 800 V/m (CW), 0.6 to 65 V/m typ. (True RMS)Dynamic Range: 62.5 dB (nominal)Flatness: +1/-1.5 dB (10 MHz to 3 GHz), +2/-1.5 dB (>3 GHz to 11 GHz)Isotropic Deviation: ±1 dB (10 MHz to 5 GHz), ±2.25 dB (> 5 GHz to 18 GHz)Applications: Broadcasting, telecommunications, and satelliteIn Stock -
ETS-Lindgren FP5083 Isotropic Electric Field Probes
SKU: 5972
Dynamic Range: 3 to 300 Volts/meter (V/m)Frequency Response: 80 MHz - 26 GHz (± 1.5 dB), 26 GHz - 40.0 GHz (± 3.0 dB)Ranges: 10, 30, 100, 300 V/m full scaleAverage Overload: 6 times full scale (each range)Battery Life: 17 Hrs continuous (full charge)$995.00 - $17,500.00Typically In Stock