The EMC Shop stocks equipment for unique test and measurement applications.
Test Applications Categories
Test Applications Test Equipment, Systems & Solutions
-
-
EM Test AutoWave for Generating and Recording Automotive Waveforms
SKU: sku-477
Weight: 6kgDimensions: 100mm x 380mm x 390mmFrequency range: DC - 50kHzGeneral Data: Technical DetailsOutput: 2 channels; 2 additional output channels can be added as an option (ExtBoard)Resolution: 16 BitSupply Voltage: AC: 90V - 250V, 47Hz - 63HzVoltage: 10V, unipolar or bipolar -
Amplifier Research (AR) FL7018 Laser Powered E-Field Probe, 3 MHz - 18 GHz
SKU: sku-278
Weight: 150 g (5.3 oz)Application/Test Type: Monitoring electric field strengths in GTEM's, Anechoic Chambers and other RF rooms for radiated immunity testing.Battery: N/ACommunication: USB, IEEE-488 (GPIB), RS-232 (serial), Fiber-Optic SerialDigital Filtering: N/ADimensions: 65 mm (2.55 in)Dynamic Range: 1 to 1,000 Volts per Meter (Single Range)Flatness: Frequency correction OFF: ±1.0 dB @ 10 MHz Frequency correction ON: typically 0.8 dB, 5 kHz–1 GHz 1.4 dB, 1 GHz–18 GHzFrequency Range: 3 MHz to 18 GHzInternal Data Memory: NoneMeasurement Mode: X-Y-Z and CompositeOperation Time: Laser Powered - SeemlessOverload: 1,600 V/m CW 16,000 V/m PeakPC Software: Optional Software for setup, automation and monitoring available.Recharging Time: N/AResolution: 0.01 V/mRF Field Probes: E-FieldSampling Rate: 20 msec/up to 50 samples per second, USB and GPIB onlySensors: Three monopolesStandards Met: IEC/EN 61000-4-3Temperature Reading Resolution: None -
Rent EM Test VDS 200N10 Automotive Battery Source and Voltage Drop Simulator, 60 V/10 A
SKU: sku-244
Common Mode Impedance: Pulses 4 and 2b (ISO 7637-2/ISO 16750-2) -
-
-
Teseq NSG 5500-2 Automotive Immunity Expandable Test System up to Five Transient Modules
SKU: sku-160
Applications: Automotive Electrical Disturbances, EV EMC TestingStandards Met: ISO 7637Max EUT DC Voltage (w/ Built In CDN): 60 VoltsMax EUT DC Current (w/ Built In CDN): 30 AmpsPeak Inrush Current Capability: 300 AmpsPre-Programmed Pulses: ISO 7637-2 (Pulse 1, 2a,3a/3b 6),SAE J1113, GM 3097, BMW, Volkswagen, PSA, Chrysler, DC 10614, Renault, FIAT, Mitsubishi, Honda, Ford ES-XW7T -
AH Systems AK-18G Antenna Kit for FCC, MIL-STD, VDE and TEMPEST Testing up to 18 GHz
SKU: 7149
Applications: Radiated Immunity, Radiated EmissionsStandards Met: FCC, MIL-STD-461, VDE, TEMPEST TestingAntenna Case Dimensions: 28" x 23" x 10"Tripod Case Dimensions: 46" x 8" DiameterInquire for Availability -
EMC Partner CDN-KIT1000 ED3
SKU: 35425
Standard: IEC 61000-4-5Application: surge on 2 unsymmetrical linesTest level surge: max. 6 kVEUT voltage per line: max. 200 V DC or 240 V peakEUT current per line: max. 4 A cont. or 5 A for 5 min.Typically In Stock -
EM Test OCS 500N6F Simulator for Fast/Slow Damped Oscillatory Waves and Ringwave
SKU: 10413
Burst duration: 50 ms ±20%, at 3 MHz 15 ms ±20%, at 10 MHz 5 ms ±20%, at 30 MHzDamping Rate: Peak 5 to be more than 50% of peak 1 value Peak 10 to be less than 50% of peak 1 valueOscillation Frequency: 3 MHz, 10 MHz and 30 MHz, ±10%Source Impedance: 50 ohm ±20%Voltage: Voltage (o.c.) at HV output 450 V - 4,400 V ±10%Burst Duration: At least 2sDamping Rate-2: Peak 5 to be more than 50% of peak 1 value Peak 10 to be less than 50% of peak 1 valueFast Damped Oscillatory Waves: As Per EN/IEC 61000-4-18Frequency: 100 kHz ± 10%General Data: Technical DetailsImpedance: 12ohm and 30ohm ± 20%Oscillation Frequency-2: 100kHz and 1MHz ± 10%Peak current: Max. 500A @ 12ohm or Max. 200A @ 30ohm internally;Polarity-2: Positive, negativePulse repetition: 1 to 60 transients per minuteRepetition Rate: Max. 5,000 /s ±10%Ringwave 0.5 μs/100 kHz: Pulse conforms to IEC/EN 61000-4-12 and ANSI (IEEE) C62.41Source impedance: 200ohm ± 20%Spike frequency: 100kHz ± 10%Test Voltage: 250 V - 6,000 V ± 10%Equipment Group: Ring Wave Generators/SimulatorsInquire -
3ctest SG 5010H 10kV Surge Simulator for IEC 61000-4-5, GB/T, ITU-T K21/K44
SKU: sku-326
Polarity: +/-, positive first or negative firstWeight: Approximately 300 kgCombination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5Coupling: 1 or 3 Phase 16 Amps 250V/450VImpedance: 500Ω±10%Input voltage UIN: AC220V±10%,50/60HOutput Current: 10/700 and 5/320±20%μsPolarity-2: +/-, positive first or alternatePulse current (short circuit): 150A - 3kA/5kA (±10%)Pulse voltage (open circuit): 300V - 6kV/10kV (±10%)Standards Met: EN/IEC 61000-4-5, IEC 61643-1, GB/T 17626.5m GB/T 16927.1, ITU-T K21 and ITU-T K44Telecom Surge: As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendationsTest duration: Voltage - 50μs(±20%); Current - 20μs(±20%)Test Voltage: 300V~6Kv/10kV (±10%)Transfer Impedance: 15Ω、40Ω(25+15Ω -
Teseq ITS 6006 Radiated Immunity Test System
SKU: 11290
Frequency Range: 80 MHz to 6 GHzInput: External AM input: BNC socket, impedance more than 10 kΩ External PM input: BNC socket, TTLOutput: Generator outputs: 4x N sockets 50 Ω, 80 MHz to 6 GHz Interlock outputs: 4x BNC sockets External PM output: BNC socket, TTL, impedance more than 1.2 kΩ 10 MHz reference output: BNC socket, approx. 0 dBm/50 ΩReference frequency: 10 MHzApplications: RF/Radiated Immunity & Susceptibility TestingTest Standards: MIL-461 RS103, IEC/EN 61000-4-3, ISO 11452-2, DO-160 Section 20$1,975.00 - $18,000.00In Stock