The Teseq NSG 4070C-35 Compact immunity test system NSG 4070C, 4 kHz - 1 GHz RF generator and power meter (with integrated power amplifier 35 W module 150 kHz - 230 MHz) is a multi-functional device for carrying out EMC immunity tests to accompany development and conformity testing in accordance to EN/IEC 61000-4-6, Namur and several automotive BCI standards. Anyone who spends a considerable amount of time on test level setting, connecting EUT monitoring or writing test reports can now carry out immunity testing in a much more efficient manner with the 4th generation of NSG 4070. Its modular set-up using internal or external amplifiers enables a large variety of applications. The powerful and easy to use firmware makes the NSG 4070 independent from an external PC and control software, however it can also be remote controlled for system operation. A state-of-the-art data transfer of test and measurement data for documentation is provided by USB stick to be plugged into the front panel.
Teseq NSG 4070C-35 Overview
- CONFIGURATIONS
- SPECIFICATIONS
- ADDITIONAL INFO
- ASSOCIATED EQUIPMENT
Teseq NSG 4070C Specifications
White Noise Generator | ||||||
Frequency Range | 150 kHz to 230 MHz | |||||
RF Level | ||||||
Level range | min -60 dBm/Hz to -40 dBm/Hz | |||||
Broadband signal flatness | < ±3 dB (150 kHz to 80 MHz) | |||||
Out of band attenuation | > 20 dB (100 MHz) | |||||
Pulse Modulation | ||||||
Rise/fall time (10%/90%) | < 1 µs | |||||
Modulation frequency range | 1 Hz to 10 Hz | |||||
Frequency resolution | 1 Hz | |||||
Duty cycle | 10% to 90% | |||||
Power Meter | ||||||
Frequency range | 9 kHz to 1 GHz | |||||
Linear Measurement Range | ||||||
Channel 1 | -35 dBm to +27 dBm | |||||
Channel 2, 3 | -45 dBm to +20 dBm | |||||
Max. input/no damage | ||||||
Channel 1-3 | +28 dBm | |||||
Noise Level | >5 dB below the measurement range | |||||
Input Return Loss | >20 dB (below 500 MHz), >17 dB (500 MHz to 1 GHz) | |||||
Connector | BNC socket, 50 Ohm | |||||
Accuracy 10 to 30°C | ||||||
Power Amplifier | ||||||
Frequency Range | 150 kHz to 230 MHz | |||||
Input Impedance | 50 Ohm | |||||
Output Impedance | 50 Ohm | |||||
Input Return Loss | min. 10 dB | |||||
Output Return Loss | Nominal min. 9.5 dB, 0 dB without damage | |||||
Gain | min.: 50 dB | |||||
Gain Flatness | max. +/- 3 dB | |||||
Saturated OutputPower | min. 49 dBm | |||||
Linear Output Power | min. 48 dBm | |||||
Max. input power without damage | max. +10 dBm | |||||
Harmonic distortion at linear output power | typ. < -20 dBc | |||||
Analog Ports | ||||||
Front Panel | ||||||
Generator Output | N socket 50 Ohm, 4 kHz to 1 GHz | |||||
Power Amplifier Input | N socket 50 Ohm, max. +10 dBm | |||||
Power Amplifier Output | N socket 50 Ohm | |||||
Power Meter Channel 1 to 3 | as defined in chapter “Power meter“ | |||||
Back Panel | ||||||
Monitoring Input Analog | BNC socket, 0 to 24 V Ri=15 k?, 6 mV resolution | |||||
External modulation input | BNC socket, impedance >10 k?, level: 1 Vpp to get 100% AM, 1 Hz to 50 kHz | |||||
Digital Ports | ||||||
Front Panel | ||||||
USB | USB host connector for USB stick, keyboard, mouse | |||||
Back Panel | ||||||
User port | D-Sub 15 pole with 4 TTL inputs, 4 TTL outputs, +12 V / 800 mA, -12 V/200 mA and +5 V/800 mA power supply | |||||
Monitoring digital input | BNC socket 0 to 24 V via optical coupler Ri=1.5 kOhm switching threshold approx. 2 to 3 V | |||||
Monitoring optical input | LWL (Light wave connector), HP versatile link HFBR0501 series 40 kBd, (avoid scattered light on the back panel) | |||||
Trigger input | BNC socket, TTL for external triggering, max. frequency 100 Hz, trigger delay <10 ms | |||||
RS232 | D-Sub 9 pole, up to 115200 Bd | |||||
RS232 optical | Connector 2 x HFBRx523 socket for 1 mm fiber optic cable with length between 5 m and 30 m with 115200 Bd, for other distances 38400 Bd, max. 50 m | |||||
2x USB | USB host connector for USB stick, keyboard, mouse | |||||
USB device connector | For remote control | |||||
Network | RJ45, Ethernet 10/100 BASE-T | |||||
General Specifications | ||||||
Mains Input | 100 to 240 VAC, 50/60 Hz, autoranging | |||||
Power Consumption | approx. 415 W | |||||
Operating Temperature range | 0°C to 40°C | |||||
Storage Temperature range | -20°C to 60°C | |||||
Relative Humidity | 95% / 30°C (no moisture condensation) | |||||
EMC | DIN/EN 61326-1:2006 | |||||
Shock | DIN/EN 60068-2-27 | |||||
Vibration | DIN/EN 60068-2-6 | |||||
Protection Class | DIN/EN 61010-1/IEC 61010-1 | |||||
Size (W x H x D) | 45 cm (19“) x 15 cm (3HU) x 42.3 cm (with handle bar and foot) | |||||
Weight | approx. 15 kg (with internal power amplifier), approx. 8 kg (without internal power amplifier) | |||||
Size of Cardboard Box | 80 cm x 61 cm x 34 cm (also for options ATN 60xx and/or LE 4070 additional space available) | |||||
Weight of Cardboard Box | Approx. 8 kg (empty) |
Teseq NSG 4070 - How to Setup Remote Control to PC
The optical link adapter can be very difficult to connect and should be avoided unless absolutely needed. Utilizing a LAN cable, connecting to the Teseq NSG 4070 software for remote use is simple and completed in a few simple steps. The EMC Shop stocks the Teseq NSG 4070 and all the accessories to complete RF conducted immunity testing to IEC 61000-4-6, ISO 11452-4, MIL-STD 461 CS114 and other test standards.