Teseq NSG 4070C-35 Test System for Conducted RF Immunity to IEC 61000-4-6

Condition:
Refurbished
Test Capabilities:
RF Conducted Immunity
Standards Met:
IEC/EN 61000-4-6, MIL-461 CS114, ISO 11452-4
Applications:
Bulk Current Injection Testing, RF Conducted Immunity
CDN Test Levels (w/ built-in amplifier):
30Vrms
BCI Test Levels (w/ built-in amplifier):
200mA
Frequency Range (w/ built-in amplifier):
150 kHz - 230 MHz
Manufacturer:
Teseq
Online Orders Ship Same Day

 

Teseq NSG 4070C-35 Downloads

Datasheet

User Manual

Quick Start Guide

$19,500.00

 

SKU:
10548
Availability:

Typically In Stock


Getting Started...

Teseq NSG 4070C-35 Overview

The Teseq NSG 4070C-35 Compact immunity test system NSG 4070C, 4 kHz - 1 GHz RF generator and power meter (with integrated power amplifier 35 W module 150 kHz - 230 MHz) is a multi-functional device for carrying out EMC immunity tests to accompany development and conformity testing in accordance to EN/IEC 61000-4-6, Namur and several automotive BCI standards. Anyone who spends a considerable amount of time on test level setting, connecting EUT monitoring or writing test reports can now carry out immunity testing in a much more efficient manner with the 4th generation of NSG 4070. Its modular set-up using internal or external amplifiers enables a large variety of applications. The powerful and easy to use firmware makes the NSG 4070 independent from an external PC and control software, however it can also be remote controlled for system operation. A state-of-the-art data transfer of test and measurement data for documentation is provided by USB stick to be plugged into the front panel.

Teseq NSG 4070C Specifications

White Noise Generator
Frequency Range 150 kHz to 230 MHz
RF Level
Level range min -60 dBm/Hz to -40 dBm/Hz
Broadband signal flatness < ±3 dB (150 kHz to 80 MHz)
Out of band attenuation > 20 dB (100 MHz)
Pulse Modulation
Rise/fall time (10%/90%) < 1 µs
Modulation frequency range 1 Hz to 10 Hz
Frequency resolution 1 Hz
Duty cycle 10% to 90%
Power Meter
Frequency range 9 kHz to 1 GHz
Linear Measurement Range
Channel 1 -35 dBm to +27 dBm
Channel 2, 3 -45 dBm to +20 dBm
Max. input/no damage
Channel 1-3 +28 dBm
Noise Level >5 dB below the measurement range
Input Return Loss >20 dB (below 500 MHz), >17 dB (500 MHz to 1 GHz)
Connector BNC socket, 50 Ohm
Accuracy 10 to 30°C  
Power Amplifier
Frequency Range 150 kHz to 230 MHz
Input Impedance 50 Ohm
Output Impedance 50 Ohm
Input Return Loss min. 10 dB
Output Return Loss Nominal min. 9.5 dB, 0 dB without damage
Gain min.: 50 dB
Gain Flatness max. +/- 3 dB
Saturated OutputPower min. 49 dBm
Linear Output Power min. 48 dBm
Max. input power without damage max. +10 dBm
Harmonic distortion at linear output power typ. < -20 dBc
Analog Ports
Front Panel
Generator Output N socket 50 Ohm, 4 kHz to 1 GHz
Power Amplifier Input N socket 50 Ohm, max. +10 dBm
Power Amplifier Output N socket 50 Ohm
Power Meter Channel 1 to 3 as defined in chapter “Power meter“
Back Panel
Monitoring Input Analog BNC socket, 0 to 24 V Ri=15 k?, 6 mV resolution
External modulation input BNC socket, impedance >10 k?, level: 1 Vpp to get 100% AM, 1 Hz to 50 kHz
Digital Ports
Front Panel
USB USB host connector for USB stick, keyboard, mouse
Back Panel
User port D-Sub 15 pole with
4 TTL inputs,
4 TTL outputs,
+12 V / 800 mA, -12 V/200 mA and +5 V/800 mA power supply
Monitoring digital input BNC socket
0 to 24 V via optical coupler Ri=1.5 kOhm
switching threshold approx. 2 to 3 V
Monitoring optical input LWL (Light wave connector), HP versatile link HFBR0501 series 40 kBd, (avoid scattered light on the back panel)
Trigger input BNC socket, TTL for external triggering, max. frequency 100 Hz, trigger delay <10 ms
RS232 D-Sub 9 pole, up to 115200 Bd
RS232 optical Connector 2 x HFBRx523 socket for 1 mm fiber optic cable with length between 5 m and 30 m with 115200 Bd, for other distances 38400 Bd, max. 50 m
2x USB USB host connector for USB stick, keyboard, mouse
USB device connector For remote control
Network RJ45, Ethernet 10/100 BASE-T
General Specifications
Mains Input 100 to 240 VAC, 50/60 Hz, autoranging
Power Consumption approx. 415 W
Operating Temperature range 0°C to 40°C
Storage Temperature range -20°C to 60°C
Relative Humidity 95% / 30°C (no moisture condensation)
EMC DIN/EN 61326-1:2006
Shock DIN/EN 60068-2-27
Vibration DIN/EN 60068-2-6
Protection Class DIN/EN 61010-1/IEC 61010-1
Size (W x H x D) 45 cm (19“) x 15 cm (3HU) x 42.3 cm (with handle bar and foot)
Weight approx. 15 kg (with internal power amplifier),
approx. 8 kg (without internal power amplifier)
Size of Cardboard Box 80 cm x 61 cm x 34 cm
(also for options ATN 60xx and/or LE 4070 additional space available)
Weight of Cardboard Box Approx. 8 kg (empty)

Teseq NSG 4070 - How to Setup Remote Control to PC

The optical link adapter can be very difficult to connect and should be avoided unless absolutely needed. Utilizing a LAN cable, connecting to the Teseq NSG 4070 software for remote use is simple and completed in a few simple steps. The EMC Shop stocks the Teseq NSG 4070 and all the accessories to complete RF conducted immunity testing to IEC 61000-4-6, ISO 11452-4, MIL-STD 461 CS114 and other test standards.

Videos

Teseq NSG 4070C-35 Key Considerations

Manufacturer:
Teseq
Test Capabilities:
RF Conducted Immunity
Standards Met:
IEC/EN 61000-4-6, MIL-461 CS114, ISO 11452-4
Applications:
Bulk Current Injection Testing, RF Conducted Immunity
CDN Test Levels (w/ built-in amplifier):
30Vrms
BCI Test Levels (w/ built-in amplifier):
200mA
Frequency Range (w/ built-in amplifier):
150 kHz - 230 MHz
Videos:
Calibration Example, Remote Operation Setup

Connect with The EMC Shop

Our experienced staff can help you with applications, purchase and rental options.