3ctest CCS 600 Conducted Immunity Test System

Condition:
New
Applications:
Electrical Transient and Noise, Surge Immunity, Power Failures
Built in CDN:
250 Volts/20 Amps
EFT/Burst Pulse Output Capability:
4.8 kV
Combination/Wave Surge Output Capability:
6 kV
Test Standards:
IEC 61000-4-5, IEC 61000-4-4, IEC 61000-4-11, IEC/EN 61000-4-29
Generic Standards:
IEC 61000-6-1, IEC 61000-6-2
Test Setup:
Conducted Immunity/Susceptibility Test Setup
Manufacturer:
3ctest
Online Orders Ship Same Day

 

3ctest CCS 600 Downloads

Datasheet

 

Availability:

Typically In Stock

SKU:
10327

 

This product is available for shipping to North America and Western European countries.


Getting Started...

Check out our Google Reviews

3ctest CCS 600 Overview

SKU-12174

Includes:

  • CCS 600 Burst and Surge Tests with CDN
  • Test Cable (Red)
  • Test Cable (BLK x3)
  • Test Cable (Blue x2)
  • Test Cable (YEL/GR x2)
  • BNC Cable
  • Ground Cable
  • Fuse X4
  • Power cord
  • PCM 260 Transformer
  • Manual
  • Calibration certificate with data (ISO 17025 available)

 

The 3ctest CCS600 is an economic multifunctional conducted immunity test system, as per all the requipments of international stadards and product standards for transient pulse, surge and voltage dips. It is an ideal option for full compliance immunity testing as per the requirements of EU CE certification and CCC certification of single phase devices. It has an automatic single phase coupling/decoupling network built in and can be setup with a three phase coupling network for five wire testing up to 100 Amps.

Test Standards Met

  • IEC 61000-4-5
  • IEC 61000-4-4
  • IEC 61000-4-8
  • IEC 61000-4-9
  • IEC 61000-4-11
  • IEC 61000-4-29
  • IEC 61008-1
  • IEC 61009-1
  • GB/T 17626.4
  •  
  • EN 61000-4-5
  • GB/T 17626.5
  • EN 61000-4-9
  • EN 61000-4-4
  • EN 55101-4
  • EN 61000-4-11
  • EN 61008-1
  • EN 61543
  • EN 61000-4-8
  • EN 61000-4-29
  • ANSI/IEEE C62.41
  • GB/T 17626.8
  • GB/T 17626.9
  • GB/T 17626.11
  • GB/T 17626.29

Power Line Coupling/Decoupling Networks

Surge Data Line Couplers

Also Ordered with the CCS 600

Surge & EFT Test Setup

Videos

3ctest CCS 600 Key Considerations

Manufacturer:
3ctest
Applications:
Electrical Transient and Noise, Surge Immunity, Power Failures
Built in CDN:
250 Volts/20 Amps
EFT/Burst Pulse Output Capability:
4.8 kV
Combination/Wave Surge Output Capability:
6 kV
Test Standards:
IEC 61000-4-5, IEC 61000-4-4, IEC 61000-4-11, IEC/EN 61000-4-29
Generic Standards:
IEC 61000-6-1, IEC 61000-6-2
Test Setup:
Conducted Immunity/Susceptibility Test Setup

Connect with The EMC Shop