Amplifier Research

(Showing 12 of 115)
Show 12 24 36 48 96

Amplifier Research Categories

Amplifier Research Test Equipment, Systems & Solutions

  • A.R. 500A100A Solid State RF Amplifier, 500 Watts CW, 10 kHz - 100 MHz

    SKU: sku-775

    Weight: 150 lbs
    Dimensions: 19.8 x 16.8 x 21.7 in
    Flatness: .± 1.5 dB maximum ± 0.5 dB with internal leveling
    Frequency Range: 10 kHz - 100 MHz
    Gain: GAIN (at maximum setting).........57 dB minimum GAIN ADJUSTMENT (continuous range)....25 dB minimum
    Impedance: 50 ohms
    Input: 180 - 264 VAC 47 - 440 Hz, 2000 watts maximum @ 0.99 P.F. typical
    Output: POWER OUTPUT, CW Nominal .... 617 watts Minimum...... 500 watts Linear @ 1 dB compression .. 300 watts minimum
    RF Connector: Type N female
    RF Input Voltage: 1.0 milliwatt maximum for rated output
    Inquire for Availability
  • A.R. 3500A100 High Power RF Amplifier

    SKU: sku-741

    Weight: 900 lbs.
    Dimensions: 22.1 x 60.0 x 39.4 in
    Flatness: ± 1.5 dB maximum ± 0.5 dB with internal leveling
    Frequency Range: 10 kHz - 100 MHz instantaneously
    Gain: 66 dB minimum
    Impedance: 50 ohms
    Input: 180-267 VAC Delta (4 wire) 360-435 VAC, Wye (5 wire) (user must specify) 47-63Hz, 3 phase 15,000 watts maximum at .99 P.F. typical
    Output: POWER OUTPUT @ 3 dB COMPRESSION Typical.... 3000 watts Minimum .. 2700 watts POWER OUTPUT @ 1 dB COMPRESSION Typical...... 2500 watts Minimum ... 2000 watts
    RF Connector: Type N female
    RF Input Voltage: 1.0 milliwatt maximum for rated output
    Inquire for Lead time
  • Amplifier Research 100S1G4M1 Solid-state Amplifier, 100 Watts CW, 0.8-4.2 GHz

    SKU: sku-739

    Weight: 190 lbs.
    Dimensions: 19.8 x 18.5 x 24.0in
    Flatness: FLATNESS............... ±1.5 dB typical ........................ ±2.0 dB maximum .......... ± 1dB with Internal Leveling
    Frequency Range: 0.8 – 4.2 GHz
    Gain: GAIN (at maximum setting)... 50 dB minimum GAIN ADJUSTMENT ........ (Continuous Range) .....15 dB minimum . (4096 steps remote)
    Impedance: 50 ohms
    Input: 99-260 VAC
    Output: POWER OUTPUT @ 3dB COMPRESSSION Nominal....... 120 watts Minimum ........... 90 watts POWER OUTPUT @ 1dB COMPRESSION Nominal............. 100 watts Minimum ...... 70 watts
    RF Connector: Type N female
    RF Input Voltage: 1.0 milliwatt maximum for rated output
  • Amplifier Research FP7060 E-Field Probe Kit, 27 MHz – 60GHz, 0.7–300 V/m

    SKU: 11650

    Weight: 350g approx
    Application/Test Type: electric field measurement instrument for use in EMC and EMI applications
    Battery: 2 built-in NiMH batteries, size AA, rechargeable, changed by operator, 40 hours operating life per charge.
    Communication: 10 m glass cable
    Dimensions: Approx. 420 x 85 x 65 mm including base and probe
    Frequency Range: 27MHz–60GHz
    Measurement Mode: composite values
    Operation Time: 40 hours operating life per charge.
    Recharging Time: Standard recharger included, 3 hour charge time
    RF Field Probes: E-Field
    Sampling Rate: 60Hz, 50Hz, 5 Hz. - user selectable
    Sensors: Isotropic
  • Used Amplifier Research AR 25A250AM6 1-300 MHz, 25 Watt RF Power Amplifier

    SKU: sku-529

    Weight: 35 LBs
    Dimensions: 19.8 x 6.1 x 11.80 in
    Flatness: ± 1.5 dB
    Frequency Range: 10 kHz - 250 MHz instantaneously
    Gain: High Range: 61 dB; Low Range: 47 dB
    Impedance: 50 ohms
    Input: 90-135/180-270 VAC 47 to 63 Hz, single phase 200 watts maximum
    Output: Power output @ 3dB compression Nominal 32 watts Minimum 25 watts Power output @ 1 dB compression Nominal 20 watts Minimum 15 watts
    RF Connector: Type N female
    RF Input Voltage: 1.0 milliwatt maximum for rated output
  • Amplifier Research FI7000 Probe Interface

    SKU: sku-438

    Weight: without enclosure 2.5 kg (6.25 lb) with enclosure 7.25 kg (16 lb)
    Application/Test Type: Monitoring electric field strengths in GTEM's, Anechoic Chambers and other RF rooms for radiated immunity testing.
    Communication: IEEE-488 (GPIB) USB 2.0, Test and Measurement class RS-232 (19200 Baud) Fiber Optic Serial (19200 Baud) reserved for connection to FM7004A Field Monitor Laser Fiber Optic Serial reserved for connection to one FL/PL 7000 series probe
    Dimensions: without enclosure 48.3 x 4.5 x 25.4 cm (19.0 x 1.75 x 10.0 in) with enclosure 49.8 x 12.7 x 30.5 cm (19.6 x 5.0 x 12.0 in)
    RF Connector: (2) E2000 compact duplex female for probe communication and safety fiber loop (2) FSMA for fiber connection to FM7004A
    Standards Met: IEC/EN 61000-4-3
    Supply Voltage: 90-260 VAC, 50-60 Hz