Overview
The 3ctest TIS 60T1 Surge Simulator is designed according to Toyota TSC0502G, which is capable of simulating the various types of negative surges discharged form the inductive system load. It can generate square wave (Fig. 2a) and burst waveform (Fig.2b) with easy and intuitive settingdesign.
Features:
- 5.7” color touch screen;
- Satisfy the test requirement of negative surge test specified inToyotaTSC0502G;
- Built-in DC switch for spark test;
- Ethernet and RJ45 interface for PC remote control and test report printing
[split]
Suitable for
- Toyota TSC0502G
- Toyota TSC3500G
- Toyota TSC3590G
- Toyota TSC7001G
- Toyota TSC7203G
- Toyota TSC7306G
Technical Parameters for Spark Surge: Square Wave and Burst Waveform |
|
Output Voltage of Spark Surge (Vs) |
-46 V(+1,-554 V) when connected to 25 Ω±0.5 Ω load -462 V(+10,-138 V)(when connected to 1 kΩ±0.02 kΩ load |
Spark Surge Duration |
Square Wave 0.1~1.5 ms Burst Waveform 50 μs±5 μs |
Single Pulse of a Burst |
Rise Time tr 5~10 ns Pulse Width td: 0.5 μs ~1.0 μs |
Negative Surge Peak (Vp) |
-100 V±2 V 25 Ω±0.5 Ω -120 V±2 V 1 kΩ±0.02 kΩ |
Time Constant of Negative Surge Waveform τ |
0.02 s±0.001s 25 Ω±0.5 Ω No requirement 1 kΩ±0.02 kΩ |
Waveform Duration Time |
1s |
Test Repetition |
2s |
Counter |
1-999 |
DUT Load(optional) |
30 A 50 A 75 A 100 A |
General Parameters |
|
Working Power Supply |
AC 110V/220V±10% 50/60Hz±5% AC 220V 50Hz in mainland China by default |
Ambient Temperature |
5℃ ~ 23℃ |
Relative Humidity |
25% ~ 70% |
Atmospheric Pressure |
86kPa ~ 106kPa |
Dimension |
4U |
Weight |
Approx. 40 kg |