EN/IEC 61000-4-6

(Showing 12 of 40)

The EMC Shop stocks and rents this test equipment, allowing customers to preliminary evaluate their products before attempting certification. The IEC/EN 61000-4-6 test standard should be purchased, read and followed to develop a suitable test plan and effectively evaluate your product.

Testing to IEC 61000-4-6?

IEC 61000-4-6 is a standard for testing electromagnetic disturbances along data and power lines that run to and from your product (DUT = Device Under Test). While intimidating to decipher the 89 pages of edition 5 of EN/IEC 61000-4-6, it's testing techniques are simple and will help flush out other problem areas that arise in EMC testing. Most of our custommers usually call in, rent equipment and contact us with the equipment in hand. Dialing in the test setup, sequence or anything else is usually quickly resolved to get testing underway.

IEC 61000-4-6 Procedure & Setup

    • In lab or in place?
    • Determine test levels and coupling devices
    • Performance Criteria
    • Description of the EUT exercising method
    • Setup equipment and run calibration
    • Identify nearby and external contributors (if any)
    • Run test and identify problem areas
    • The recovery time of the EUT if necessary
    • Troubleshoot accordingly

Most of our customers will simply place the test generator on a bench, ground everything, and be off and rolling. There are diagrams avaialble that specify spacing, insulation, placement of the generator, etc... We have found that in most cases, these aren't detrimental in precompliance measurements when following IEC 61000-4-6. The test standard is long and detailed, covering different test setups, injection methods, procedures and more. The EMC Shop can support this effort with information on your DUT and surrounding auxilary equipment.

Selecting CDN's According to IEC 61000-4-6

Calibration Setup Diagram acc. IEC 61000-4-6

Diagram - IEC 61000-4-6 CDN Test Setup

Test Setup Diagram acc. IEC 61000-4-6

Diagram - IEC 61000-4-6 Testing of Large Products

START TESTING

The EMC Shop ships IEC 61000-4-6 systems same day for fasy and easy precompliance testing.

Calibration Example

Test Equipment for IEC 61000-4-6

  • RF Conducted Immunity Test Generator
  • CDNs, EM Clamp or Current Clamp
  • Decoupling Device
  • Monitor Probe
  • 6dB Attenuator
  • 50 Ohm Terminations
  • Insulation Material
  • Grounding Plane
  • Calibration Kit (Optional)
  • RF Shield Room (Optional)

Show 12 24 36

EN/IEC 61000-4-6 Test Equipment, Systems & Solutions

  • EM Test CWS 500N1 Continuous Wave Simulator for IEC 61000-4-6

    SKU: sku-410

    Weight: 17 kg (37.5 Pounds)
    Application/Test Type: Create and output RF currents as well as measure input for CDN and clamp calibration as well as current monitor for clamp applications
    Dimensions: 19"/3 HU
    Frequency Range: Sinus (CW) 100kHz to 300MHz Frequency bands 100kHz to 9.999MHz 10MHz to 99.99MHz 100MHz to 300MHz
    Impedance: 50 Ohms
    Input: 115 V to 230 V +10/-15 %, 50/60 Hz (380 Watts Max)
    Maximum Continuous Power: 80W (nominal)
    Standards Met: IEC 61000-4-6
    Test Routines: Quick Start, User Test Routines, Standards Test Routines (IEC/EN 61000-4-6), Cal Procedure, Service
    Voltage Rating: 1 V to 30 Volts Max
    Inquire for Availability
  • Teseq CDN M5 5-Line Coupling Network for AC Power Lines, 16-32 Amps

    SKU: sku-227

    Weight: 6.5 kg (14.3 LB.'s)
    Application/Test Type: 5 mains AC power lines emissions testing up to 32 Amps (3L+N+PE)
    Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 Ω
    Current Rating: 32 Amps Maximum
    Decoupling of Common Mode Disturbance: Greater than 30 dB
    Dimensions: 6.3 x 6.3 x 20 inches (16.0 cm x 16.0 cm x 50.0 cm)
    Frequency Range: 150 kHz to 230 MHz (Optional 10 kHz - 80 MHz)
    Insertion Loss: Greater than 0.1 dB
    Mains & EUT Connections: 4 mm, safety (Optional IEC 320 16A)
    RF Connector: BNC, 50 Ω
    RF Input Voltage: Less than 30 V
    Standards Met: IEC 61000-4-6
    Voltage Division Factor: 10 dB +3 dB / -1 dB
    Voltage Rating: AC max. voltage (line to ground) / (line to line): 250 V / 433 V (CDN M216-1000V: 500 V / 1000 V); DC max. voltage (line to ground) / (line to line): 400 V / 800 V (CDN M216-1000V: 1000 V / 2000 V); Test voltage: 3 kV DC, 2 sec
  • Teseq (Schaffner) KEMZ 801A EM Clamp Conform with IEC/EN 61000-4-6

    SKU: sku-119

    Weight: approx. 7 kg
    Application/Test Type: Injects the disturbance signal through a combination of inductive and capacitive coupling
    Clamp factor (CF): Max (0.15 to 400 MHz): 4 dB (50 Ω system) and 13.5 dB (150 Ω system)
    Connector: N-type female
    Dimensions: 647 mm x 130 mm x 105 mm
    Frequency Range: 10 kHz to 1000 MHz
    Impedance: 50 Ohms
    Max. Cable Diameter: 20 mm
    Maximum Continuous Power: 0.01 to 100 MHz: 100 W for 15 min; 100 to 230 MHz: 100 W for 3 min; 230 to 1000 MHz: 50 W for 3 min
    Standards Met: IEC/EN 61000-4-6; CISPR 24; EN 61000-6-1; EN 61000-6-2; IEC 60533; IEC 60601-1-2; IEC 61326
  • Com-Power CDN-M525E 5-Line Coupling Decoupling Network for Unscreened Power Lines

    SKU: sku-91

    Weight: 5 lbs. 2.3 kg
    Application/Test Type: five conductor power cable
    Common Mode Impedance: 150 kHz - 26 MHz: 150Ω ± 20Ω 26 MHz - 80 MHz: 150Ω + 60Ω / – 45Ω 80 MHz - 230 MHz: 150Ω + 60Ω / – 60Ω
    Current Rating: 25 Amps AC / 17 Amps DC (Max)
    Decoupling of Common Mode Disturbance: ≥ 40dB (EUT/AE)
    Dimensions: 6 x 6 x 13 inches 15.2 x 15.2 x 33 cm
    Frequency Range: 150 kHz to 230 MHz
    Mains & EUT Connections: 4 mm shrouded banana sockets
    RF Connector: 50 Ω BNC (Female)
    RF Input Voltage: 40 V (Max)
    Standards Met: IEC / EN 61000-4-6
    Voltage Division Factor: 9.5 dB +4 / -1
    Voltage Rating: 250 V AC / 350 V DC (Line to Ground)
  • Com-Power CDN-M425E 3-Phase + Earth Coupling Decoupling Network

    SKU: sku-90

    Weight: 5 lbs. 2.3 kg
    Application/Test Type: Four conductor power cable
    Common Mode Impedance: 150 kHz - 26 MHz: 150Ω ± 20Ω 26 MHz - 80 MHz: 150Ω + 60Ω / – 45Ω 80 MHz - 230 MHz: 150Ω + 60Ω / – 60Ω
    Current Rating: 25 Amps AC / 17 Amps DC (Max)
    Decoupling of Common Mode Disturbance: ≥ 40dB (EUT/AE)
    Dimensions: 6 x 6 x 13 inches 15.2 x 15.2 x 33 cm
    Frequency Range: 150 kHz to 230 MHz
    Mains & EUT Connections: 4 mm shrouded banana sockets
    RF Connector: 50 Ω BNC (Female)
    RF Input Voltage: 40 V (Max)
    Standards Met: IEC / EN 61000-4-6
    Voltage Division Factor: 9.5 dB +4 / -1
    Voltage Rating: 250 V AC / 350 V DC (Line to Ground)
  • Schwarzbeck CDN M4PE 32A Coupling Decoupling Network

    SKU: 6657

    Frequency Range: 150 kHz to 230 MHz
    Common Mode Impedance: 150 kHz – 24 MHz: 150 Ω ±20 Ω, 24 MHz–80 MHz: 150 Ω +60 Ω/-45 Ω, 80 MHz–230 MHz: 150 Ω ±60 Ω
    Max. RF Test Voltage: 30 V
    RF Input Power: 6 W
    Input voltage EuT (AE): Line to ground / line to line: 500 VAC / 1000 VDC, 1000 VAC / 2000 VDC
    EUT, AE Connectors: 4 mm safety banana (f)
    Test Standards: IEC 61000-4-6
    $295.00 - $3,095.00
    Typically In Stock