Overview
EFP18G Isotropic Electric Field Probe 3 MHz - 18 GHz Details
The EFP18G Isotropic Electric Field Probe operates in 3 MHz to 18 GHz covering test requirements requirements of most EMC and RF safety standards for industrial, military and radar communication applications. Utilizing the software, monitor average field strength or levels at all three individual axis. The EFP18G has a high overload limit and stability of the parameters make this probe a versatile measuring tool for use for all testing.
Diode based: 3-Axial isotropic sensor.
-
Sensitivity: 0.8 V/m
-
Linearity: +/- 0.5 dB (1-400 V/m)
-
+/- 1 dB (400-800 V/m)
-
-
Dynamic range: >60 dB (single range)
-
Frequency response (without correction factors);
-
- +/- 1.5 dB (10 MHz–6 GHz), -3 dB @ 3 MHz
- +/- 3 dB (6 GHz–12 GHz)
- Frequency response (with correction factors):
- +/- 1.0 dB (10 MHz–12 GHz)
- +/- 3 dB (12 GHz–18 GHz)
- Rotational isotropicity:
- +/- 0.5 dB (3 MHz-6 GHz)
- +/- 2 dB (6 GHz –18 GHz)
- Calibration accuracy (at specified freq.) <1 dB
- Temperature: 5-40 °C
- Humidity: RH 10-90%, non-condensing.
- Temperature error: <0.05 dB/°C (field > 2 V/m)
- UK NPL or NIST traceable calibration
- Small size: LxD: 9.0x2.25 inch, 230x58 mm
- Weight: 0.2 lb, 100 g.
- Operates with both RFP-04 and RFP-05 meters