PMM L3-100 Three Phase 100 Amp LISN for CISPR 16-1-2

Condition:
Used
Weight:
70 kg (154 pounds)
Current Rating:
100 Amps continuous (125 Amps overload for 5 minutes)
Dimensions:
465 x 450 x 740 mm (18.3 x 17.7 x 29 inches) - mounted on pallet for mobility
Frequency Range:
9 kHz to 30 MHz
Inductors:
50 Ω // [5 Ω + 50 µH] with 250 µH choke
Mains & EUT Connections:
125 A plug and socket outlet according to IEC309 standard
RF Connector:
BNC (f)
Standards Met:
CISPR 16-1-2, VDE 0876, FCC Part 15, MIL-STD 461F
Voltage Rating:
230 VAC, 325 VDC (L-PE and N-PE); 400 VAC, 565 VDC (L-L and L-N)
Manufacturer:
PMM
Online Orders Ship Same Day

 

Availability:

Inquire for Availability

SKU:
10058

 

This product is available for shipping to North America and Western European countries.


Getting Started...

Check out our Google Reviews

Overview

Please note this unit must ship freight.

The AMN - Artificial Mains Network, also known as LISN - Line Impedance Stabilization Network - is the ancillary device intended for repeatable and accurate measurement of the disturbance voltage that an EUT (Equipment Under Test) may inject into the power line or mains. This is obtained by providing well known impedance value and phase response across the frequency range of the test.

PMM L3-100 three phase, 100 Amp LISN is for CISPR 16-1-2, and suitable for measurement on AC 3-phase power circuits from DC to 60 Hz. The equivalent V-Network circuit of 50 Ω // (5 Ω + 50 μH) with 250 μH choke is fully compliant with the reference standards.

PMM Artificial Mains Networks provide robust and stable mechanical construction, high quality electric components, easy and perfect grounding, solid input-output power connections. They can be used in conjunction with any EMI receiver or spectrum analyzer and offer features required for safe, repeatable and accurate measurements

PMM L3-100 Features:

  • 9 kHz a 30 MHz frequency range
  • 100 A max output current
  • Large baseplate for optimal grounding
  • Local and remote control for PMM EMI receivers
  • Meets the requirements of several standards including CISPR 16-1-2, VDE 0876, FCC part 15
  • Powering the EUT
  • EUT termination to a standardized impedance respect to the reference ground
  • Coupling the measuring receiver to the disturbance generated by the EUT
  • Decoupling the measuring receiver from unwanted RF signals from the power line

Videos

Key Considerations

Manufacturer:
PMM
Weight:
70 kg (154 pounds)
Current Rating:
100 Amps continuous (125 Amps overload for 5 minutes)
Dimensions:
465 x 450 x 740 mm (18.3 x 17.7 x 29 inches) - mounted on pallet for mobility
Frequency Range:
9 kHz to 30 MHz
Inductors:
50 Ω // [5 Ω + 50 µH] with 250 µH choke
Mains & EUT Connections:
125 A plug and socket outlet according to IEC309 standard
RF Connector:
BNC (f)
Standards Met:
CISPR 16-1-2, VDE 0876, FCC Part 15, MIL-STD 461F
Voltage Rating:
230 VAC, 325 VDC (L-PE and N-PE); 400 VAC, 565 VDC (L-L and L-N)

Connect with The EMC Shop