8616-5-TS-200-N 5uH EMI LISN Overview
The EMC Shop stocks many Solar 8616-5-TS-200-N 5uH EMI LISNs, rentals ship the same day, purchases within 2-3 business days. ISO 17025 calibrations available.
The Solar EMC LISNs use a series inductor between the test sample and the power source to provide the impedance-versus-frequency characteristic. A coaxial connector with DC isolation is provided for connection to the associated frequency selective EMI spectrum analyzer.
EMI specifications require one LISN in each ungrounded power lead. Even though the neutral is considered "ground" if it is not connected to chassis inside the unit under test, the lead must be tested with an LISN. Therefore, use two LISNs in DC or single phase AC applications, three LISNs for delta-connected three phase circuits, and four LISNs for Y-connected three phase circuits.
Rated Current |
200 Amps |
Voltage (line to ground) |
400 VDC, 270 V 50-60 Hz, 135 V 400 Hz |
Inductance |
5µH |
Frequency Range |
150 kHz – 65 MHz |
RF connector |
Type N |
Coupling Capacitor |
.10 µF |
Case Size |
0.25” X 9.25” X 13” |