Overview
The magnetic field strength produced by Helmholtz coil HHS 5024-12 of 20cm semi-diameter can be calculated by current (H = 42.93xI), or use sensor coil of 13.3 cm diameter (36-turn) to measure in the center. Helmholtz coil fully comply with MI-STD-461F RS101 and ISO 11452-8 standard for magnetic field immunity test.
Parameters | ||
Model | HHS5024-12 | |
Max. current | 60 A, 5 min. | |
Rated current | 30 A continuous | |
coil space | 200 mm, 250 mm, 300 mm | |
following data when the space is 200mm | ||
Max. magnetic field strength | 2500 A/m, 5 min | |
Rated magnetic field strength | 1288 A/m continuous | |
Magnetic field strength when coil current is 1A | 42.93 A/m | |
Current | 152.66 dBμA/m | |
current needed for 1 A/m | 23.29 mA | |
transfer factor between current and strength | 32.66 dB/m | |
coil diameter | 400 mm | |
size | 0.38 m x 0.58 m x 0.42 m | |
frequency range | 15 - 500 kHz | |
Inductance?each coil?? | 120 μH | |
Inductance?a pair of coil?? | 240-260 μH | |
resistance?each coil?? | 47.5 mW | |
capacitance?a pair of coil?? | 52 pF | |
Harmonic frequency?a pair of coil? | > 1.4 MHz | |
weight | 10.2 kg |