Coupling Decoupling Networks (CDN's)

(Showing 12 of 92)

The EMC Shop stocks coupling decoupling networks (CDN's) for most power and data line configurations. CDN's are quintessential for performing EMC testing. In short, conducted immunity coupling networks ensure electrical transients are sent down the path of the line to the EUT. Decoupling that signal from entering the rest of the network is done in different ways. In radiated immunity, you are coupling wireless signals over the air through the antenna. It may be appropriate to use a decoupling clamp on lines as they exit the test chamber.

Get Application Support, Pricing, Lead Time and More: Contact Form

Coupling/Decoupling networks are built in to most current generators for single phase power EUT. Coupling networks are typically easy to set up for conducted immunity (surge, EFT, PQF). RF conduted immunity requires an assortment of couplers and without proper setup, are easy to blow up.

Type's of Coupling Decoupling Networks

  • CDN's for Surge/EFT Immunity: Power Lines and Data Lines
  • RF CDN's for Conducted Immunity: Power Lines and Data Lines: Used for just decoupling as well
  • EM Clamps: Inject and decouple RF disturbances
  • Absorbing Clamps: Just for decoupling RF disturbances on cables (Needed for BCI Testing)
  • Bulk Current Injection Probes: Used for just coupling RF noise

Coupling/decoupling networks for RF conducted immunity have a port top-side where your inject the RF signal, an EUT side where the RF disturbances are directed to power or data lines. The decoupling path exit the AE Side and is generally safe from disturbances.

Show 12 24 36 48

Coupling Decoupling Networks (CDN's) Categories

Coupling Decoupling Networks (CDN's) Test Equipment, Systems & Solutions

  • Teseq CDN S900S RS-232 Coupling Decoupling Network for IEC 61000-4-6

    SKU: 10828

    Weight: 1.5 kg (3.3 lbs)
    Application/Test Type: Coupling / decoupling network (CDN) for screened data/telcom lines or coaxial cables
    Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 Ω
    Current Rating: 250 mA (CDN ST08 1 Amp)
    Decoupling of Common Mode Disturbance: 150 kHz: Over 60 dB; 1.5 MHz: Over 60 dB; 30 MHz: Over 50 dB; 230 MHz: Over 40 dB (refer to data sheet for some exceptions)
    Dimensions: 4 x 4 x 9.5 inches (10 cm x 10 cm x 24 cm); (CDN HDMI and CDN S752A: 28.8 cm 11 inches)
    Frequency Range: 10 kHz to 80 MHz or 150 kHz to 230 MHz
    Mains & EUT Connections: BNC 50 Ω, N 50 Ω, BNC 75 Ω, N 75 Ω, XLR 3 pins, DIN 5 pins, RJ45, D-Sub 9 pins, D-Sub 15 pins, D-Sub 25 pins, HDMI (refer to data sheet for exact model specifications)
    RF Connector: BNC 50 Ω
    RF Input Voltage: 20 Volts Max
    Standards Met: IEC 61000-4-6, CISPR 22, IEC 60601-1-2
    Voltage Division Factor: 9.5 dB to 10 dB ±1 dB (refer to data sheet for some exceptions)
    Voltage Rating: AC max. voltage (line to ground): 100 V - 250V; DC max. voltage (line to ground): 150 V - 400 V; Test voltage: 200 V - 750 V DC, 2 sec (refer to data sheet for exact model specifications)
    $1,190.00
  • Teseq CDN M016 Switchable 16 Amp Coupling/Decoupling Network

    SKU: 10827

    Associated Equipment: RF Conducted Immunity Test Systems
    Application/Test Type: switchable 2 or 3 power lines, (L+N or L+N+PE)
    Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 Ω
    Current Rating: 16 Amps
    Decoupling of Common Mode Disturbance: 150 kHz: Greater than 30 dB 1.5 MHz: Greater than 60 dB 30 MHz: Greater than 40 dB 230 MHz: Greater than 20 dB
    Dimensions: 3.9" x 3.9" x 9.5" (100 mm x 100 mm x 240 mm)
    Frequency Range: 150 kHz to 230 MHz
    Insertion Loss: Less than 0.1 dB
    Mains & EUT Connections: 4 mm banana
    RF Connector: BNC 50 Ω
    RF Input Voltage: 30 Volts (Max)
    Standards Met: IEC/EN 61000-4-6
    Voltage Division Factor: 150 kHz to 80 MHz: 9.5 dB ±1 dB 80 MHz to 230 MHz: 9.5 dB +3 dB / -2 dB
    Voltage Rating: AC max. voltage (line to ground): 250 V DC max. voltage (line to ground): 400 V; 3 kV DC, 2 sec
    $195.00 - $495.00
    Typically In Stock
  • Fischer Custom Communications FCC-801-M3-16A, 3 Line M Series CDN, 150 kHz – 230MHz, 16 Amp

    SKU: sku-731

    Application/Test Type: 3 Power Conductors
    Common Mode Impedance: Frequency dependent 150 kHz – 26MHz: 150Ω ±20Ω 26MHz – 80MHz: 150Ω +60Ω -45Ω 80MHz –230MHz: 150Ω +60Ω -60Ω
    Current Rating: 16 Amps
    Frequency Range: 150 kHz to 230 MHz
    Mains & EUT Connections: Multi-Contact Safety Socket
    RF Connector: 50 Ω BNC (Female)
    RF Input Voltage: 30 Volts
    Standards Met: IEC / EN 61000-4-6
    Voltage Division Factor: 10dB+1dB/-3dB
    Voltage Rating: DC less than 600V, AC less than 250V
  • Dressler S1 Coupling/Decoupling Networks (CDN) 150 kHz-230 MHz

    SKU: sku-399

    Weight: 1.9 Lbs (0.86 kg)
    Application/Test Type: For coupling and decoupling of interference signals on screened lines
    Current Rating: 1.5 Amps
    Dimensions: 7.25 x 4.25 x 5.75 (inches)
    Frequency Range: 150 kHz to 230 MHz
    Mains & EUT Connections: BNC
    Standards Met: IEC/EN 61000-4-6
    Voltage Rating: 100 V
  • Teseq CDN 118-T4 Coupling Decoupling Network set for 1.2/50 µs and 10/700 µs Surge Pulses on 1 or 2 twisted pairs

    SKU: 30093

    Application/Test Type: 1.2/50 μs (2 ohms) and 10/700 μs (15 ohms) pulse up to 6.6 kV line to ground, 3 kV line to line (Pulse frequency: 3 per minute)
    Current Rating: 0.5 Amps
    Decoupling chokes 1 kHz: 20 mH nominal
    Dimensions: 335 x 232 x 180mm
    Mains & EUT Connections: 4 mm safety banana; Fischer 103
    Ohmic resistance per path: 3 Ω
    Series resistor: in relation to the selected pulse coupling network
    Transmission 3 dB BW: 250 kHz
    Voltage Rating: 250 Volts AC/DC
    Inquire for Lead Time
  • 3ctest 405T8A1 Surge CDN For Unshielded Data Lines

    SKU: sku-332

    Application/Test Type: Test high-speed communication lines against lightening surge as per picture 10 in IEC/EN61000-4-5 edition 3
    Coupling: Common mode (line to ground)l 90V gas discharging tube
    Current Rating: Max 1 A
    Impedance: 200Ω ±5%
    Input: 1.2/50us, 10/700us
    Mains & EUT Connections: RJ45 female
    Standards Met: IEC 61000-4-5 Ed. 3
    Test Voltage: 6kV (10kV, customized)
    Voltage Rating: 90 VDC
    Typically In Stock
  • Teseq CDN S Series Coupling Network for Screened or Coaxial Cables

    SKU: 4255

    Application/Test Type: Coupling / decoupling network (CDN) for screened data/telcom lines or coaxial cables
    Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 Ω
    Current Rating: 250 mA (CDN ST08 1 Amp)
    Decoupling of Common Mode Disturbance: 150 kHz: Over 60 dB; 1.5 MHz: Over 60 dB; 30 MHz: Over 50 dB; 230 MHz: Over 40 dB (refer to data sheet for some exceptions)
    Frequency Range: 10 kHz to 80 MHz or 150 kHz to 230 MHz
    Mains & EUT Connections: BNC 50 Ω, N 50 Ω, BNC 75 Ω, N 75 Ω, XLR 3 pins, DIN 5 pins, RJ45, D-Sub 9 pins, D-Sub 15 pins, D-Sub 25 pins, HDMI (refer to data sheet for exact model specifications)
    RF Connector: BNC 50 Ω
    RF Input Voltage: 20 Volts Max
    Standards Met: IEC 61000-4-6, CISPR 22, IEC 60601-1-2
    Voltage Division Factor: 9.5 dB to 10 dB ±1 dB (refer to data sheet for some exceptions)
    Voltage Rating: AC max. voltage (line to ground): 100 V - 250V; DC max. voltage (line to ground): 150 V - 400 V; Test voltage: 200 V - 750 V DC, 2 sec (refer to data sheet for exact model specifications)
    $710.00 - $2,110.00
  • Teseq CDN M416 4-Line Coupling/Decoupling Network

    SKU: sku-225

    Weight: 700 grams (1.5 LB.'s)
    Application/Test Type: 3 power lines, (L+N+PE), (2L+PE), (Optional L+L+L)
    Common Mode Impedance: 150 Ω +10/-20 Ω
    Current Rating: 10 Amps Maximum
    Decoupling of Common Mode Disturbance: Greater than 30 dB
    Dimensions: 4.1 x 3 x 5 inches (10.5 x 7.5 x 12.5 cm)
    Frequency Range: 150 kHz to 230 MHz (Optional 10 kHz - 80 MHz)
    Insertion Loss: Greater than 0.1 dB
    Mains & EUT Connections: 4 mm, safety (Optional IEC 320 16A)
    RF Connector: BNC, 50 Ω
    RF Input Voltage: Less than 30 V
    Standards Met: IEC 61000-4-6, CISPR 16-1-2, CISPR 16-2-1 and CISPR 15
    Voltage Division Factor: 20 dB ±1.5 dB
    Voltage Rating: AC max. voltage (line to ground) / (line to line): 250 V / 433 V (CDN M216-1000V: 500 V / 1000 V); DC max. voltage (line to ground) / (line to line): 400 V / 800 V (CDN M216-1000V: 1000 V / 2000 V); Test voltage: 3 kV DC, 2 sec