Teseq ITS 6006 Radiated Immunity Test System

Condition:
Used
Frequency Range:
80 MHz to 6 GHz
Input:
External AM input: BNC socket, impedance more than 10 kΩ External PM input: BNC socket, TTL
Output:
Generator outputs: 4x N sockets 50 Ω, 80 MHz to 6 GHz Interlock outputs: 4x BNC sockets External PM output: BNC socket, TTL, impedance more than 1.2 kΩ 10 MHz reference output: BNC socket, approx. 0 dBm/50 Ω
Reference frequency:
10 MHz
Applications:
RF/Radiated Immunity & Susceptibility Testing
Test Standards:
MIL-461 RS103, IEC/EN 61000-4-3, ISO 11452-2, DO-160 Section 20
Manufacturer:
Teseq
Online Orders Ship Same Day
$18,000.00

 

SKU:
11290
Availability:

In Stock


Getting Started...

Overview

The Teseq ITS 6006 consist of an integrated RF signal generator, RF switch and EUT monitoring interfaces. The unit is designed for various radiated EMC applications in the 80 MHz to 6 GHz frequency range. In addition to the generator, the system includes the AM and PM modulators necessary for EMC testing. The second generation, called ITS 6006B, includes 3 freely configurable pulse modulators (1 µs to 200 s) for radar pulse profiles as required e.g. by Ford FMC1278 or VW TL81000. The RF signal can be switched to one of four outputs, where up to four power amplifiers can be connected directly. Two RF switches are supplied for combining four amplifier into two antenna paths.

ITS 6006 interlock outputs ensure the activation of the power amplifier for only the selected signal path. The 3.5“ color display shows the generator parameters. LEDs indicate the state of further functions.

The EUT monitoring is provided by six digital, one analog and one optical input, as well as four digital outputs. Up to three power meters PMR 6006 can be connected directly to the ITS 6006. The ITS 6006 provides remote control through its network, RS232 and USB interfaces.

 

Parameter Value
Frequency range

80 MHz – 6 GHz

Resolution

1 Hz

Reference frequency

10 MHz

Max. adjustment deviation

±50 Hz

Aging

5 ppm

Level range

-60 dBm to +10 dBm (-60 dBm to +8 dBm at f>3 GHz & ϑ>30°C)

Resolution

0.1 dB

Accuracy

<1 dB, typ. <0.5 dB (+15 to +25°C)

 

Videos

Key Considerations

Manufacturer:
Teseq
Frequency Range:
80 MHz to 6 GHz
Input:
External AM input: BNC socket, impedance more than 10 kΩ External PM input: BNC socket, TTL
Output:
Generator outputs: 4x N sockets 50 Ω, 80 MHz to 6 GHz Interlock outputs: 4x BNC sockets External PM output: BNC socket, TTL, impedance more than 1.2 kΩ 10 MHz reference output: BNC socket, approx. 0 dBm/50 Ω
Reference frequency:
10 MHz
Applications:
RF/Radiated Immunity & Susceptibility Testing
Test Standards:
MIL-461 RS103, IEC/EN 61000-4-3, ISO 11452-2, DO-160 Section 20

Connect with The EMC Shop

Our experienced staff can help you with applications, purchase and rental options.