Fluke 6100A Electrical Power Quality Calibrator

Condition:
Used
Manufacturer:
Fluke
Test Standards:
IEC61000-3-3, IEC 61000-4-30, EN61010-1:2001, CAN/CSA 22.2 No 1010.1-92, UL61010A-1, EN61000-3-2:2000, MIL-PRF-28800 class 3, IEC 60364-4-443
Applications:
Flicker, Harmonics, Fluctuating Harmonics, Interharmonics, Dips and Swells
Voltage:
100 V to 240 V with up to 10 % fluctuations
Range of fundamental frequency:
16 Hz to 450 Hz
Frequency Accuracy:
50 ppm

 

No reviews yet Write a Review
$2,295.00
Availability:

IN STOCK

SKU:
sku-F6100A-RE

 

Due to tariff increases, some items in our catalog are subject to additional costs when purchased.


Getting Started...

6100A Overview

The most accurate, comprehensive and flexible source of electrical power signals, the Fluke 6100A Fluke 6100A Electrical Power Quality Calibrator sets a new benchmark for accuracy in power standards. Voltage and current are generated with up to 6 digits resolution and accuracys approaching 100 ppm (0.01 %). Phase adjustment provides for 1 milli-degree or 10 micro-Radian resolution. Phase performance is exceptional, with accuracy to 3 milli-degrees and short term stability to 200 micro-degrees. In multi-phase systems phase accuracy between phases is 5 millidegrees, again with short term stability to 200 micro-degrees. This outstanding level of phase performance equals or exceeds a number of commercially available phase standards. Phase accuracy is imperative in achieving power accuracy. The 3 milli-degrees phase accuracy of the Fluke 6100A ensures power accuracy approaching 200 ppm (0.02 %) can be achieved. Simple trigonometry applied to the equation Power = VIcosø demonstrates that compromising phase performance can only severely degrade power uncertainty.

Fluke 6100A Electrical Power Quality Calibrator Specifications:

Primary specifications

Voltage/Current amplitude setting resolution: 6 digits
Range of fundamental frequency: 16 Hz to 450 Hz
Frequency accuracy: 50 ppm
Frequency setting resolution: 0.1 Hz
Time to full accuracy: 1 hour
Settling time: < 1.4 second
Nominal angle between voltage phases: 120 º
Nominal angle between voltage and current of a phase: 0 º
Phase angle setting: ± 180 º, ± π radians
Phase angle setting resolution: 0.001 º, 0.00001 radians

Harmonics

Number of harmonics available: 100 (simultaneously if required)
Maximum harmonic frequency available: 6 kHz (100th Harmonic of 60 Hz)
Maximum level of individual harmonic: 30 % of fundamental level
Setting Method (user selectable): % RMS, % fundamental, dB down from fundamental, absolute value

Flicker

Setting range: ±30 % of set voltage or current within range values (60 % ∆V/V)
Flicker modulation depth accuracy: 0.025 %
Modulation depth setting resolution: 0.001 %
Shape: Rectangular or Sinusoidal
Duty cycle (shape = rectangular): 0.1 % to 99.9 % ±31 µs
Modulating Frequency range: 0.0008 Hz to 40 Hz
Pst Indication accuracy: 0.25 % Valid for Voltage only between 220 V and 240 V

Fluctuating Harmonics

Number of harmonics to fluctuate: Any number from 0 to all set harmonics can fluctuate
Setting range: ±30 % of nominal harmonic voltage
Fluctuation accuracy: 0.025 %
Modulation depth setting resolution: 0.001 %
Shape: Rectangular or Sinusoidal
Duty cycle (shape = rectangular): 0.1 % to 99.9 % ±31 µs
Modulating Frequency range: 0.008 Hz to 30 Hz

Interharmonics

Frequency accuracy: 500 ppm
Amplitude accuracy 16 Hz to < 6 kHz: 1 %
Amplitude accuracy > 6 kHz: 4 %
Maximum value of a single interharmonic: Maximum value for an interharmonic < 2850 Hz is 30 % of range. See Extended specifications for frequencies>2850 Hz
Frequency range of interharmonics: 16 Hz to 9 kHz

Dips and swells

Dip/Swell Min duration: 0.5 cycles
Dip/Swell Max duration: 1 minute
Dip Min amplitude: 10 % of the nominal output
Swell Max amplitude: The lesser of full range value or 140 % of the nominal output
Ramp up/down period: Settable 100 µs to 30 seconds
Optional repeat with delay: 0 to 60 seconds ±31 µs
Starting level amplitude accuracy: ±0.25 % of level
Dip/Swell level amplitude accuracy: ±0.25 % of level
Trigger out: TTL falling edge coincident with start of Dip/Swell event remaining low for 10 µs to 31 µs

Power

Voltage: 100 V to 240 V with up to 10 % fluctuations
Transient overvoltages: Impulse withstand (overvoltage) category II of IEC 60364-4-443
Frequency: 47 Hz to 63 Hz
Max. consumption: 1000 VA 100 V – 130 V, 1250 VA 130 V – 240 V

Dimensions


Height: 233 mm (9.17 inches)
Width: 432 mm (17 inches)
Depth: 630 mm (24.8 inches)
Weight: 23 kg (51 lbs)

Environment

Operating temperature: 5 ºC to 40 ºC
Calibration temperature: 16 ºC to 30 ºC
Storage temperature: 0 ºC to 50 ºC
Transit temperature: -20 ºC to 60 ºC < 100 hours
Warm up time: 1 hour
Safe Operating Max. Relative Humidity (non-condensing): < 80 % 5 ºC to 31 ºC ramping linearly to 50 % at 40 ºC
Storage Max Relative Humidity (non-condensing): <95 % 0 ºC to 50 ºC
Operating altitude: 0 m to 2,000 m
Non operating altitude: 0 to 12,000 m
Shock: MIL-PRF-28800 class 3
Vibration: MIL-PRF-28800 class 3
Enclosure: MIL-PRF-28800 class 3

Videos

6100A Key Considerations

Manufacturer:
Fluke
Test Standards:
IEC61000-3-3, IEC 61000-4-30, EN61010-1:2001, CAN/CSA 22.2 No 1010.1-92, UL61010A-1, EN61000-3-2:2000, MIL-PRF-28800 class 3, IEC 60364-4-443
Applications:
Flicker, Harmonics, Fluctuating Harmonics, Interharmonics, Dips and Swells
Voltage:
100 V to 240 V with up to 10 % fluctuations
Range of fundamental frequency:
16 Hz to 450 Hz
Frequency Accuracy:
50 ppm