International (IEC/EN) Categories
International (IEC/EN) Test Equipment, Systems & Solutions
-
Schwarzbeck CMDM 8700 Common Mode / Differential Mode Switch
SKU: 11226
Frequency Range: 9 kHz – 30 MHzConnector: BNCImpedance of Line A, Line B and output port: 50 ΩVoltage division factor at the measuring port: (0 … - 2) dBTypically in Stock -
-
-
-
-
LFCI4-16/19 Test Generator for Common and Differential Mode Disturbances
SKU: 11995
Test Standards: IEC 61000-4-16, IEC 61000-4-19Frequency Range: DC, 0.05Hz - 300 kHz; resolution 0.05 HzSlew Rate: 100 V/µsInternal Power Amplifier: 250 WattsTypically In Stock -
Monthly Rental EM Test CWS 500N Continuous Wave Simulator for IEC 61000-4-6
SKU: sku-921
Weight: 17 kg (37.5 Pounds)Application/Test Type: Create and output RF currents as well as measure input for CDN and clamp calibration as well as current monitor for clamp applicationsDimensions: 19"/3 HUFrequency Range: Sinus (CW) 100kHz to 300MHz Frequency bands 100kHz to 9.999MHz 10MHz to 99.99MHz 100MHz to 300MHzImpedance: 50 OhmsInput: 115 V to 230 V +10/-15 %, 50/60 Hz (380 Watts Max)Maximum Continuous Power: 80W (nominal)Standards Met: IEC 61000-4-6Test Routines: Quick Start, User Test Routines, Standards Test Routines (IEC/EN 61000-4-6), Cal Procedure, ServiceVoltage Rating: 1 V to 30 Volts Max -
Rent ETS-Lindgren 5402 GTEM Test Cell for Small DUT
SKU: 10839
Features: Ships fully assembled, easy unpack and setupApplications: Radiated Emissions, RF/Radiated Susceptibility TestingMax DUT Size: 8" x 8" x 6"Test Standards: FCC Part 15, IEC 61000-4-3$1,750.00 - $1,755.00In Stock -
Teseq CDN M016 Switchable 16 Amp Coupling/Decoupling Network
SKU: 10827
Associated Equipment: RF Conducted Immunity Test SystemsApplication/Test Type: switchable 2 or 3 power lines, (L+N or L+N+PE)Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 ΩCurrent Rating: 16 AmpsDecoupling of Common Mode Disturbance: 150 kHz: Greater than 30 dB 1.5 MHz: Greater than 60 dB 30 MHz: Greater than 40 dB 230 MHz: Greater than 20 dBDimensions: 3.9" x 3.9" x 9.5" (100 mm x 100 mm x 240 mm)Frequency Range: 150 kHz to 230 MHzInsertion Loss: Less than 0.1 dBMains & EUT Connections: 4 mm bananaRF Connector: BNC 50 ΩRF Input Voltage: 30 Volts (Max)Standards Met: IEC/EN 61000-4-6Voltage Division Factor: 150 kHz to 80 MHz: 9.5 dB ±1 dB 80 MHz to 230 MHz: 9.5 dB +3 dB / -2 dBVoltage Rating: AC max. voltage (line to ground): 250 V DC max. voltage (line to ground): 400 V; 3 kV DC, 2 sec$195.00 - $495.00Typically In Stock -
Schloder M Type CDN's for Disturbance Signals to Unscreened Supply Lines (mains) AC + DC up to 1000V, 100A
SKU: sku-791
Application/Test Type: unscreened supply lines (mains) AC + DCCurrent Rating: 16A / 32A / 63 A / 100 ADimensions: 160 x 84,5 x 240mm or 200 x 122,5 x 400mm depending on modelFrequency Range: 150 kHz to 230 MHzMains & EUT Connections: banana socketsRF Connector: 50 Ω BNC (Female)Standards Met: IEC / EN 61000-4-6Voltage Rating: up to 250 VAC / 400 VDC -
3 Phase EFT/Burst, Surge Combination Wave Test System
SKU: 1785
Application/Test Type: CE Marking, EMC Precompliance TestingBurst (EFT) 5/50 ns: Pulse conforms to IEC/EN 61000-4-4Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5Pulse amplitude: 0.2 – 5.0 kVPulse current (short circuit): 0.1 – 2.5 kA ±10% (8 us ±20% risetime)Rentals Ship Today -
Schloder VIS 1700 Voltage Interruption Simulator
SKU: sku-784
Communication: BNC outputs (on rear) for voltage, current and scope triggeringCoupling: BNCDips, Interrupts & Variations: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29General Data: Technical DetailsMains & EUT Connections: 4mm banana lineOutput Current: AC max. 280 V, DC max. 3 6 0 VPeak inrush current capability: 16 AmpsPhase synchronization: at any phase position 0° - 360 °Test duration: 0.1sec - 9990sec, furthermore single event and continuous operationTest Voltage: AC max. 280 V ,DC max. 3 6 0 VApplications: EMC Precompliance Testing, Conducted ImmunityTypically In Stock