International (IEC/EN) Categories
International (IEC/EN) Test Equipment, Systems & Solutions
-
Chase CIP-8212 1 GHz BCI Probe for Conducted Susceptibility
SKU: 5787
Frequency range: 100 kHz - 1 GHzInner diameter (I.D.): 1.7" ( 43.8 mm )Connector type: N(f)Maximum input power: 100 WattsMax current field ( @400 MHz ): 400 mAMax voltage field ( @230 MHz ): 30 VrmsTest Standards: ISO 11452-4, IEC 61000-4-6 BCI, DO-160 Section 20, MIL-STD-461$4,500.00IN STOCK -
Inquire for Availability
-
BCIP300M 10 kHz - 300 MHz, 50 Watt BCI Injection Probe
SKU: 3839
Frequency range: 10 kHz - 100 MHzInner diameter (I.D.): 1.50" ( 38 mm )Connector type: N(f)Maximum input power: 100 WattsMax current field ( @400 MHz ): 250 mAMax voltage field ( @230 MHz ): 25 VrmsTest Standards: IEC 61000-4-6 BCI, MIL-STD-461 CS114$295.00 - $3,250.001 Left -
-
-
Fischer Custom Communications F-61 Current Monitor Probe, 1 MHz - 1 GHz
SKU: 4565
AC Current Handling (DC-400Hz): 200 AmpsRF Current Handling (CW/Pulse): 20/50 AmpsStyle: Clamp On (Fixed Window)Inner Diameter: 32 mmTransfer Impedance: 22 Ω ± 2 dB from 100 MHz to 900 MHzTest Standards: MIL-STD-461 CE101Frequency Range: 1 MHz to 1 GHz$325.00 - $475.00In Stock -
Com-Power CLEM-6146 RF Injection Device for Conducted Immunity
SKU: sku-524-1
Standards: EN/IEC 61000-4-6NOTE: Our price includes CLEMA-6146 calibration adapters (150 Ohm to 50 Ohm)Frequency Range: 10 kHz to 1000 MHzMax. Cable Diameter: 0.75"Maximum Continuous Power: 10 kHz to 100 MHz: 100 W for 15 min; 100 to 230 MHz: 100 W for 5 min; 230 to 1000 MHz: 50 W for 3 min$11,780.00Inquire for Lead Time -
3ctest CWS 800 8kV Surge Combination Wave Simulator for IEC/EN 61000-4-5 up to 8 kV
SKU: sku-797
Weight: Approx 30 kg (66 lbs)Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5Coupling: Single Phase Built in, 16A, 250VAC, 120VDCDimensions: 19 inch/6uImpedance: 2 OhmMains & EUT Connections: 4mm banana plugPhase synchronization: 0°-360°, 1°step or randomPolarity: Positive, Negative, AlternatePulse current (short circuit): 0.1kA-3kA ±10%Pulse repetition: 1-999Pulse voltage (open circuit): 0.2kV - 8kV ±10%Standards Met: IEC 61000-4-5, UL1449 and more -
Amplifier Research (AR) FL7018 Laser Powered E-Field Probe, 3 MHz - 18 GHz
SKU: sku-278
Weight: 150 g (5.3 oz)Application/Test Type: Monitoring electric field strengths in GTEM's, Anechoic Chambers and other RF rooms for radiated immunity testing.Battery: N/ACommunication: USB, IEEE-488 (GPIB), RS-232 (serial), Fiber-Optic SerialDigital Filtering: N/ADimensions: 65 mm (2.55 in)Dynamic Range: 1 to 1,000 Volts per Meter (Single Range)Flatness: Frequency correction OFF: ±1.0 dB @ 10 MHz Frequency correction ON: typically 0.8 dB, 5 kHz–1 GHz 1.4 dB, 1 GHz–18 GHzFrequency Range: 3 MHz to 18 GHzInternal Data Memory: NoneMeasurement Mode: X-Y-Z and CompositeOperation Time: Laser Powered - SeemlessOverload: 1,600 V/m CW 16,000 V/m PeakPC Software: Optional Software for setup, automation and monitoring available.Recharging Time: N/AResolution: 0.01 V/mRF Field Probes: E-FieldSampling Rate: 20 msec/up to 50 samples per second, USB and GPIB onlySensors: Three monopolesStandards Met: IEC/EN 61000-4-3Temperature Reading Resolution: None -
EM Test OCS 500N6F Simulator for Fast/Slow Damped Oscillatory Waves and Ringwave
SKU: 10413
Burst duration: 50 ms ±20%, at 3 MHz 15 ms ±20%, at 10 MHz 5 ms ±20%, at 30 MHzDamping Rate: Peak 5 to be more than 50% of peak 1 value Peak 10 to be less than 50% of peak 1 valueOscillation Frequency: 3 MHz, 10 MHz and 30 MHz, ±10%Source Impedance: 50 ohm ±20%Voltage: Voltage (o.c.) at HV output 450 V - 4,400 V ±10%Burst Duration: At least 2sDamping Rate-2: Peak 5 to be more than 50% of peak 1 value Peak 10 to be less than 50% of peak 1 valueFast Damped Oscillatory Waves: As Per EN/IEC 61000-4-18Frequency: 100 kHz ± 10%General Data: Technical DetailsImpedance: 12ohm and 30ohm ± 20%Oscillation Frequency-2: 100kHz and 1MHz ± 10%Peak current: Max. 500A @ 12ohm or Max. 200A @ 30ohm internally;Polarity-2: Positive, negativePulse repetition: 1 to 60 transients per minuteRepetition Rate: Max. 5,000 /s ±10%Ringwave 0.5 μs/100 kHz: Pulse conforms to IEC/EN 61000-4-12 and ANSI (IEEE) C62.41Source impedance: 200ohm ± 20%Spike frequency: 100kHz ± 10%Test Voltage: 250 V - 6,000 V ± 10%Equipment Group: Ring Wave Generators/SimulatorsInquire -
Teseq ITS 6006 Radiated Immunity Test System
SKU: 11290
Frequency Range: 80 MHz to 6 GHzInput: External AM input: BNC socket, impedance more than 10 kΩ External PM input: BNC socket, TTLOutput: Generator outputs: 4x N sockets 50 Ω, 80 MHz to 6 GHz Interlock outputs: 4x BNC sockets External PM output: BNC socket, TTL, impedance more than 1.2 kΩ 10 MHz reference output: BNC socket, approx. 0 dBm/50 ΩReference frequency: 10 MHzApplications: RF/Radiated Immunity & Susceptibility TestingTest Standards: MIL-461 RS103, IEC/EN 61000-4-3, ISO 11452-2, DO-160 Section 20$18,000.00In Stock -
3ctest EFT 700 Burst/EFT Simulator up to 7 kV with Single or Three Phase CDN
SKU: sku-566
Test Capabilities: EFT Immunity, Medical DevicesStandards Met: IEC/EN 61000-4-4Applications: CE Marking, Medical Devices, Industrial Machinery, Electronics & ITMax EUT AC Voltage (w/ Built in CDN): 250 Volts (380V w/ 3PH CDN)Max EUT AC Current (w/ Built in CDN): 16 AmpsMax EUT DC Voltage (w/ Built in CDN): 220 VoltsMax EUT DC Current (w/ Built in CDN): 16 AmpsEFT/Burst Pulse Output Capability: 7 kVExternal Coupling: Data Lines