(Showing 12 of 1980)
Show 12 24 36 48 96

Categories

Test Equipment, Systems & Solutions

  • 3ctest SG3483 Multiple Waveform Lightning Surge Simulator for IEC 61000-4-5

    SKU: sku-605

    Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5
    Counter: unlimited
    Output: Output waveform 1, 2, 3: 2kV - 20kV
    Polarity: pos / neg / alternate
    Pulse current (short circuit): 2kV ±10%@50A ±10% 6kV ±10%@150A ±10% 10kV ±10%@250A ±10% 15kV ±10%@375A ±10% 20kV ±10%@500A ±10%
    Pulse repetition: automatic 2 s – 100 min (Manual and external triggering available)
    Pulse voltage (open circuit): 2kV ±10% 6kV ±10% 2kV ±10% 10kV ±10% 15kV ±10% 20kV ±10%
    Standards Met: IEC 61000-4-5
    Supply Voltage: 220V(±10%)/50Hz
  • Com-Power LI-3P-200 Series 3-Phase LISN's with 50/250 uH Inductor, FCC/EN/CISPR, up to 100 A, 150 kHz - 30 MHz

    SKU: sku-603

    Weight: 27.5 lbs.
    Application/Test Type: Power Line Conducted Emissions Tests
    Current Rating: up to 100 Amperes
    Dimensions: 19.3” x 13.9” x 2.3"
    Frequency Range: 9 kHz to 30 MHz
    Inductors: 50 µH or 250 µH
    Insertion loss: less than 0.7 dB
    Isolation: more than 40 dB
    Mains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power Jack
    RF Connector: RF Measurement Port 50Ω - N-Type (female)
    Standards Met: ANSI C63.4, CISPR 16-1-2
    Voltage Rating: 500 Volts rms (line to line), 288 Volts rms (line to ground) Max DC Voltage: 705V
  • Teseq NSG 3060-ITU Transient Generator for Surge, Telecom, EFT/Burst, IEC and ITU-T.K

    SKU: 10406

    Test Capabilities: Combination Wave Surge Immunity , EFT/Burst, Dips Interrupts & Variations
    Standards Met: IEC/EN 61000-4-4, IEC/EN 61000-4-5, IEC/EN 61000-4-11, IEC/EN 61000-4-29
    Applications: CE Marking, Medical Devices, Industrial Machinery, Electronics & IT
    Max EUT AC Voltage (w/ Built in CDN): 264 Volts
    Max EUT AC Current (w/ Built in CDN): 16 Amps
    Max EUT DC Voltage (w/ Built in CDN): 220 Volts
    Max EUT DC Current (w/ Built in CDN): 10 Amps
    Peak inrush current capability: 500 A (at 230 V)
    EFT/Burst Pulse Output Capability: ±200 V to 4.8 kV (in 1 V steps) - open circuit±100 V to 2.4 kV ±100 A to 2.2 kA
    Combination/Wave Surge Output Capability: ±200 V to 4.4 kV (in 1 V steps)
    External Coupling: Data Lines (EFT & Surge), 3PH EUT
    Coupling: ANSI / IEC / external
    Phase synchronization: asynchronous, synchronous 0 to 359º (in 1º steps)
    Polarity: positive / negative / alternate
    Test duration: 1 s to 1000 h
    Burst (EFT) 5/50 ns: Pulse conforms to IEC/EN 61000-4-4
    Burst frequency: 100 Hz to 1000 kHz
    Burst time: 1 μs to 1999 s, single pulse, continuous
    Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5
    Coupling-2: ANSI / IEC / external
    Impedance: 2/12 Ω
    Output Current: 5 to 500 A
    Phase synchronization-2: asynchronous, synchronous 0 to 359º (in 1º steps)
    Polarity-2: positive / negative / alternate
    Pulse amplitude: ±200 V to 4.8 kV (in 1 V steps) - open circuit; ±100 V to 2.4 kV (50 Ω matching system)
    Pulse current (short circuit): ±100 A to 3.3 kA
    Pulse repetition: 5* to 20 s, up to 600 s (in 1 s steps) * derated depending on selected pulse voltage and EUT supply voltage
    Pulse voltage (open circuit): ±200 V to 6.6 kV (in 1 V steps)
    Repetition Rate: 10 to 600 s
    Repetition time: 1 ms to 4200 s (70 min)
    Telecom Surge: As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendations
    Test duration-2: 1 to 9999 pulses, continuous
    Test Voltage: 200 to 7.7 kV
    Transfer Impedance: 15 and 40 Ω
    Inquire for Availability
  • 3ctest CDN 405AF8 Surge Coupling/Decoupling Network for Data Lines

    SKU: 30092

    Application/Test Type: Test low-speed communication lines against lightening surge as per figure 12 in IEC/EN61000-4-5 edition 3
    Coupling: 4 pair unshielded assymetric lines
    Current Rating: Max 1 A
    Impedance: 200Ω ±5%
    Inductors: 20 mH Decoupling
    Input: 1.2/50us, 10/700us
    Mains & EUT Connections: RJ45 female
    Standards Met: IEC 61000-4-5 Ed. 3
    Test Voltage: 6kV (10kV, customized)
    Voltage Rating: 90 VDC
    Inquire for Lead Time
  • Teseq CBL 6144 Ultra-broadband BiLog Antenna for Compact Chambers

    SKU: 10118

    Impedance: 50 Ohms
    Weight: approx. 6.5 kg
    Antenna Factor (1 Meter): 4 to 3 dB/m
    Antennas: Bilogical Antennas
    Application/Test Type: Ultra-broadband immunity antenna For compact chambers Reduced chamber coupling
    Connector: N type female
    Dimensions: (L x H x W in mm): approx. 1585 X 1570 X 670
    Frequency Range: 26 MHz to 3 GHz (useable to 20 MHz)
    Gain: 6 dB (200 MHz to 3 GHz) / 8 dB (700 MHz to 2.5 GHz)
    Impedance-2: 50 Ω
    Maximum Continuous Power: 600 Watts
    Standards Met: IEC/EN 61000-4-3,CISPR 13,CISPR 14-1,CISPR 16-1-4,CISPR 16-2-3,CISPR 22,CISPR 24,CISPR 32,EN 61000-6-1,EN 61000-6-2,EN 61000-6-3,EN 61000-6-4,IEC 60533,IEC 60601-1-2,IEC 61326,ISO 11452-2
    Inquire for Availability
  • ETS-Lindgren 3301C Active Monopole Antenna

    SKU: sku-1894

    Max Frequency: 50 MHz
    Min Frequency: 30 Hz
    Application/Test Type: Active, general-purpose, receive-only antenna for FCC, MIL-STD and TEMPEST tests
    Connector: BNC (female)
    Impedance: 50 Ohms
    Standards Met: CISPR 16-1-6: 2017, Mil-STD-461, ANSI C63.5 and SAE, ARP-958
    Antenna Factor: -3 dBm - 13 dB/m

Connect with The EMC Shop

Our experienced staff can help you with applications, purchase and rental options.