Categories
Test Equipment, Systems & Solutions
-
Amplifier Research 100W1000C RF Amplifier 1-1000 MHz, 100 Watt CW
SKU: sku-1309
Frequency Range: 1-1000 MHzOutput Power: 100 WattsFlatness: ±2.0 dB maximum, ±1.5 dB typical, ±0.8 dB with internal levelingGain: 50 dB minimumInput Impedance: 50 Ω, VSWR 2.0:1 maximumOutput Impedance: 50 Ω nominalInquire for Availability -
Schwarzbeck USLP 9143 UHF-SHF Log. - Per. Broadband Antenna
SKU: 1283
Nominal Frequency Range: 300 MHz - 7 GHzUsable Frequency Range: 250 MHz - 8 GHzIsotropic Gain: typ. 5.8 dBi + / - 1.3 dBAntenna Factor: 14 dB/m - 43 dB/mNominal Impedance: 50 ΩStanding Wave Ratio SWR typical: < 1.5Front to Back Ratio: >25 dB ( >500 MHz)Cross Polarisation: >20 dB (250 MHz...2.5 GHz)3 dB Beamwidth typ. (E-Plane): 30°-80°3 dB Beamwidth typ. (H-Plane): 60°-140°Max. Input Power: 200 W (< 500 MHz), 80 W (5 GHz), 50 W (7 GHz)Typically In Stock -
Schwarzbeck FMZB 1519 B Active Receive Loop Antenna
SKU: 30112
Frequency Range: 9 kHz – 30 MHzAntenna Factor for fict. E-field Strength: 20 dB/mAntenna Factor for H-field Strength: -31.5 dB/ΩmLoop Diameter: 0.5 mApplications: Antenna Pattern MeasurementInquire for Availability -
Schwarzbeck BBV 9718 B Microwave Broadband Amplifier
SKU: 1241
Nominal Frequency Range: 1 - 18 GHzUseable Frequency Range: 0.5 - 20 GHzConnectors: 50 Ω N / SMAMounting Tube: Ø 22 mmGain: Typ. 33 dB +/- 2.5 dBInquire for Availability -
Rigol EMI Precompliance Test Equipment Bundle
SKU: 11165
Applications: EMC Precompliance Testing, Conducted Emissions, Radiated EmissionsLimit Lines: CISPR 11, MIL-STD-461, FCC Part 15 and moreBundle Includes: DSA710, EMI-DSA800, NFP-3, S1210 EMIs, interconnect cablesFrequency Range: 100 kHz to 1 GHz$259.00 - $1,295.00Typically In Stock -
Radiated Emissions Testing Equipment for FCC, MIL and More
SKU: sku-1164
Generic Standards: IEC 61000-6-3, IEC 61000-6-4 -
Schwarzbeck NNBL 8240 Line Impedance Stabilisation Network
SKU: 30015
Test Standards: MIL-STD-461EApplications: Conducted Emissions, BCI Testing , Automotive EV EMCAdditional Applications: MilitaryFrequency Range: (9) 150 kHz – 100 MHzMax. Continuous Current: 800 AMax. Current (limited time): 1000 AMax. Voltage DC: 1000 VMax. Voltage 50/60 Hz: 650 VImpedance: (50 µH + 5 Ω) || 50 Ω ±20 %Resistance of Coil: < 3 mΩInquire for Availability -
Rohde & Schwarz Precompliance EMI Emissions Test Equipment Package
SKU: sku-1125
Applications: EMC Precompliance Testing, Conducted Emissions, Radiated EmissionsLimit Lines: CISPR 11, MIL-STD-461, FCC Part 15 and moreIn stock -
-
-
EM Test CNV 504 Coupling/Decoupling Network
SKU: 30017
Test Standards: IEC 61000-4-5Applications: Data lines Unshielded, Symmetrical Surge ImmunityInquire for Availability -
Typically In Stock