Overview
Select-A-Shield™ RF EMI Shielding Portable Enclosures
MOBILE TENTS OFFER ADVANTAGES OVER HARDWALL ROOMS
Select Fabricators’ RF EMI Shielding Portable Enclosures border on the performance of fully welded metal rooms, meeting shielding requirements without the added expenses of installation, removal and re- installation. Prototype and pre- compliance testing of electronic and wireless devices, temporary EMI shielding and secure communications all need on-site, economical shielding. SELECT developed a US made material and uses a choice of three frame structures with numerous options to manufacture table top to room-sized enclosures with optimum attenuation.
Independent testing to IEEE® 299 of a complete assembled tent system including installed components resulted in a minimum signal attenuation of -85.7 dB over a range of frequencies from 400 MHz to 18 GHz measuring through the wall at multiple locations.
VIRTUALLY ANY SIZE | |
OPTIMUM PROTECTION |
WHEN YOU HAVE TO SHIELD . . . SELECT
Enclosure Construction Shielding Effectiveness:
Tested with internal vestibule design, high performance I/O plate and AC line filter. -85.7 dB minimum from 400 MHz to 18 GHz (see chart)
Double Layer Enclosure
Tested with filter box using standard performance AC line filter, no vestibule. -78 dB average from 150 kHz to 18 GHz
Single Layer Enclosure
Tested with filter box using standard performance AC line filter, no vestibule. -66 dB average from 150 kHz to 18 GHz
Industries Served Commercial Wireless
| Technology Sectors
|
Simple to set up, with lightweight pop-up or semi-permanent frames.
SERIES 100 FRAMES Easy-up steel frame. From 8’ x 8’ to 10’ x 20’ with adjustable height. Custom sized enclosures are available. See chart to the right below for standard sizes. | |
SERIES 300 FRAMES Rectangular heavy-duty aluminum frame. With a wide range of structural profiles, frames are configured to meet enclosure size and weight requirements. Excellent for large sized tents and cleanroom applications. | |
SERIES 500 FRAMES Round heavy-duty aluminum frame. The easy “socket connection principle” of the internal tension system reduces construction assembly to a minimum. A connection is established effortlessly by simply tightening a clamping screw. | |
PATENTED DOOR SYSTEMS Single door, US Pat. No. 9,029,714 or double door, US Pat. No. 8,530,756 patented door seal systems deliver maximum isolation. Reduces RF/EMI leakage for enhanced performance. | |
IO FILTER PLATE Choose from an integrated I/O Filter Plate with standard or high attenuation power filter. Provides a power line and optional filtering for Ethernet and USB. Custom multiple filter and connector options are also available which can include: SMA, BNC and Fiber Optics, etc. |
OPTIONS:
- Cleaning in SELECT’s on-site ISO Class 7 cleanroom
- Door Sizes 5’ x 5’ and larger
- ESD white interior liner
- Filter plates
- High Attenuation Power Filters
- Filter boxes with standard line filter
- Cable sleeves
- Frame roller bags and hard travel cases
- LED interior perimeter lighting or EMI hardened stringed lights
- Testing of completed enclosure
- Ventilation
- Ventilation with Air Conditioning
- Vestibule
- Viewing Window - RF shielded
Tent Enclosure / Frame Sizes (custom sizes are always an option) | ||||||
Enclosure Size | Frame Size | |||||
Part Number | Length (feet) | Width (feet) | Height (feet) | Length (feet) | Width (feet) | Height(feet) |
Series 100-080808 | 7’ | 7’ | 6' 6" | 8’ | 8’ | 8’ |
100-080810 | 7’ | 7’ | 8' | 8’ | 8’ | 9’ 7" |
100-101008 | 9’ | 9’ | 6' 6" | 10’ | 10’ | 8’ |
100-101010 | 9’ | 9’ | 8' | 10’ | 10’ | 9’ 7" |
100-101508 | 9’ | 14’ | 6' 6" | 10’ | 15’ | 8’ |
100-101510 | 9’ | 14’ | 8' | 10’ | 15’ | 9’ 7" |
100-102008 | 9’ | 19’ | 6' 6" | 10’ | 20’ | 8’ |
100-102010 | 9’ | 19’ | 8" | 10’ | 20’ | 9’ 7" |
100-102012 | 9’ | 19’ | 10' | 10’ | 20’ | 11’ 7" |
Series 500-484878 | 4’ | 4’ | 6' 6" | 5’ | 5’ | 7’ |