ETS Lindgren Series 101 RF Shielded Room Overview
TGet a used ETS Lindgren Series 101 RF shielded room delivered and built immediately with The EMC Shop. The EMC Shop recycles ETS-Lindgren chambers and shielded rooms as companies move and change.
Modular Design
The modular structure allows for very flexible adaptation to the customer's needs and requirements. Both the size and shape of the room can be designed to meet the site specific conditions. As the modular design is standardized to provide maximum flexibility, Series 101 is not limited to the use of only a few standard size panels. However, the automated manufacturing technology utilizes the advantages of high quantity production of standardized panels.
The same manufacturing technology can be applied to different materials such as hot galvanized steel and aluminum. The requirements can be realized by using same machinery, thus enabling cost-effective solutions and a competitive price-quality-ratio in addition to material selection to customize a solution ideally suited to a customer's needs.
Installation
The panel system provides a reliable and high performance shielding, as the panels are jointed with special gasket. However, at the same time the number of fasteners can be minimized, which also shortens the assembly time. The Series 101 panels can be bolted from inside or from outside, depending on the purpose and requirements. The shielded room can also include a combination of flat sides inside and outside.
When installing the enclosure from inside (flat side outside), the enclosure can be assembled in close proximity, without a supporting structure within 5 cm (2 in) of the existing walls of the parent building. The panel bends (flanges) can be used for installing inner lining or absorber rails when appropriate.
When installing the enclosure from outside (flat side inside), the connections from the support structure does not penetrate the shielding and the inside of the enclosure is flat. This is required in partial discharge/high voltage testing halls as well as when either ferrites or absorbers are glued directly onto the walls and ceiling. Please note that the space required for the installation work of an outside bolted enclosure is about 800 mm (31.5 in) all around, also above the roof.
Performance
As the Series 101 corner joint is identical to the intermediate joint, no additional supports or special construction is required. The corners have equally reliable attenuation as the rest of the enclosure. Electromagnetic interference has no way in or out. This is just an example epitomizing that the Series 101 enclosure forms a carefully designed entity with painstaking attention to detail.
[split]
Size - 16' x 12' x 10'
Door Width - 5'