Overview

The Teseq’s new NSG 3060A conducted immunity generator takes the proven, user-friendly design of the highly successful NSG 3000 series to a new level. This innovative design uses modular architecture to provide a versatile system that can be configured for basic testing needs and expanded to meet the needs of sophisticated test laboratories.

Designed to fulfill requirements for CE mark and ANSI C62.41 testing, the Teseq NSG 3060A performs tests for Combination wave surge, Ring wave and Electrical Fast Transient (EFT) pulses as well as Power Quality Testing (PQT). Extensive expansion capabilities enable the system to be configured for a much broader range of applications.

Using state of the art components, the self-contained modules set new standards with respect to switching and phase accuracy and exceed the existing standards’ requirements. With its powerful processors, the NSG 3060A can completely fulfill the unique coupling requirements specified by ANSI C62.41. This standard requires that the pulse amplitude be adjusted for the phase position of the pulse on the AC mains, and for the amplitude of the mains voltage.

A 7” touch panel display with superb contrast and color is the most striking feature of the new NSG 3060A. For fast and efficient data entry, input devices include an integrated keyboard and a thumbwheel with additional keys for sensitivity adjustment.

The user-friendly graphic display speeds test setup. Each parameter’s value is highly visible, and all settings can be quickly selected and modified with the generously sized touch input buttons. A stylus is not necessary, and ramp functions are programmed quickly and easily. Multi-step test procedures can be created and their sequence or parameter values changed easily.

The users can make manual parameter changes using the thumbwheel while a test is under way, providing an effective and fast method for identifying critical threshold values. The Test Assistance (TA) function allows users to initiate standardized test with just a few “clicks” to achieve quick, reliable results in a development environment.

The Teseq NSG 3060A has an Ethernet port for external PC control. The Windows-based control software simplifyes test programming and allows compilation of complex test sequences with diverse pulse types. Test reports can be generated during the test operation, allowing the operator to enter observations as the test progresses and increasing the efficiency of long-term tests.

Model EFT/Burst Surge PQT Ring wave TelecomSurge
NSG 3060A-IEC
NSG 3060A-ANSI
NSG 3060A-FULL

The Teseq NSG 3060A performs tests according to the following Specifications
Combination wave pulse 1, 2/50 - 8/20 µs (Hybrid-Surge pulse)
Pulse conforms to IEC/EN 61000-4-5 and ANSI (IEEE) 62.41
Parameter Value
Pulse voltage (open circuit) ±200 V to 6.6 kV (in 1 V steps)
Pulse current (short circuit) ±100 A to 3.3 kA
Impedance 2/12 Ω
Polarity positive / negative / alternate
Pulse repetition 10 s* up to 9’999 s (in 1 s steps)
Test duration 1 to 99’999 pulses, continuous
Phase synchronization asynchronous, synchronous 0 to 359º (in 1º steps)
Coupling ANSI / IEC / external
* Repetition rate depends on voltage 200 to 4400 V = 10 s repetition time
4401 to 6600 V = 20 s repetition time
Ring wave 0.5 µs/100 kHz
Pulse conforms to IEC/EN 61000-4-12 and ANSI (IEEE) C62.41
Parameter Value
Pulse voltage (open circuit) ± 200 V to 6.6 kV (in 1 V steps)
Pulse current (short circuit) ±16.6 to ±550 A, ±10%
±6.6 to ±220 A, ±10%
±1 to ±33 A, ±10%
Impedance 12/30 Ω
Polarity positive / negative / alternate
Pulse repetition 10 s* up to 9’999 s (in 1 s steps)
Test duration 1 to 99’999 pulses, continuous
Phase synchronization asynchronous, synchronous 0 to 359º (in 1º steps)
Coupling ANSI / IEC / external
* Repetition rate depends on voltage 200 to 4400 V = 10 s repetition time 4401 to 6600 V = 20 s repetition time
Burst (EFT) 5/50 ns
Pulse conforms to IEC/EN 61000-4-4
Parameter Value
Pulse amplitude ±200 V to 4.8 kV (in 1 V steps) - open circuit
±100 V to 2.4 kV (50 Ω matching system)
Burst frequency 100 Hz to 1000 kHz
Polarity positive / negative / alternate
Repetition time 10 ms to 9'999 ms
Burst time 0.01 ms to 9'999 ms, single pulse
Test duration 1 s to 9’999s, 1 min to 1600 min, endless
Phase synchonization asynchronous, synchronous 0 to 359º (in 1º steps)
Coupling internal / external
Dips & Interrupts
conforms to IEC / EN 61000-4-11, IEC / EN 61000-4-29
Parameter Value
Dips & Interrupts From EUT voltage input to 0 V, 0% (1)
Uvar with optional variac depending on model (VAR 3005A)
Uvar with step transformer 0, 40, 70, 80% (INA 650xA)
Peak inrush current capability > 500 A (at 230 V)
Switching times 1 to 5 μs (100 Ω load)
Event time (T-Event) 20 µs to 9999 s, 0.5 to 9’999 cycles
Repetition time 10 ms to 9’999 ms, 1 to 9’999 s
Test duration 1 to 99’999 events, endless
Phase synchronization asynchronous, synchronous 0 to 359º (in 1º steps)
(1) In combination with VAR 3005A-S16, effective minimal dip voltage ~8 V. As specified in IEC 61000-4-11, chapter. 5.1 a test voltage level from 0% to 20% of the rated voltage is considered as a total interruption.
Variation test (with VAR 3005A-S16 only)
Parameter Value
Uvar with optional variac up to 265 V (in 1 V steps) or up to 115% Uin (in 1% steps)
Decreasing time Td 1 ms to 9.999 ms, 0.5 to 9999 cycles, abrupt
Time at reduced voltage Ts 1 ms to 9.999 ms, 0.5 to 9999 cycles,
Increasing time Ti 1 ms to 9.999 ms, 0.5 to 9999 cycles,
Repetition time 1 s to 9’999 s
Events 1 to 99’999
Pulsed magnetic field in conjunction with MFC 30
conforms to IEC/EN 61000-4-9
Parameter Value
Field 100 to 1200 A/m
Polarity positive / negative / alternate
Repetition time 10 s to 9999s (in 1 s steps)
Impedance 2 Ω
Coil / impedance factor 0.01 to 100.00
Test duration 1 to 9’999 pulses, endless
Phase synchronization asynchronous, synchronous 0 to 359º (in 1º steps)
Power magnetic field in conjunction with MFT 30 or MFO 6501A and MFC 30 / MFC 300
conform to IEC/EN 61000-4-8
Parameter Value
Field 1 to max. 40 A/m (in 1 A/m steps)
Frequency 50/60 Hz
Coil factor 0.01 to 99.99
Test duration 1 to 9’999 pulses, continuous
Internal Coupling Network
Parameter Value
EUT supply 1-phase
EUT VAC Up to 300 Vrms *, 50 / 60 Hz (phase - neutral)
EUT VDC Up to 300 VDC
EUT current 1 x 16 Arms continuous (over heat protected)
Connections
Front panel - EUT: 4mm banana plug
- Burst OUT 50 Ω SHV
- Trigger out BNC
Rear panel - EUT supply: banana plug 4 mm
- Additional ground connector
- Instrument supply 85 V to 264 VAC
- Connector surge HV – COM
Surge Standard coupling as per IEC 61000-4-5
Coupling mode Line to Line
Line(s) to ground
Mains decoupling 1.5 mH 0% + 35%
Decoupling attenuation Residual pulse voltage on EUT power supply inputs 15 % max.
Residual voltage on non-pulsed EUT power supply inputs 15 % max
EFT (Burst) Standard coupling all lines to ref ground (GND) IEC / EN 61000-4-4
L, N, PE to ref GND
Any lines and combination to ref GND
L to ref GND
N to ref GND
PE to ref GND
L, N to ref GND
L, PE to ref GND
N, PE to ref GND
PQT Dips & interrupts to phase L
Technical Specification
Instrument supply 85 to 265 VAC, 50 / 60 Hz
Dimensions NSG 3060A-IEC 19”; 6 HU, 448 x 289 x 500 mm (W x H x D)
Weight NSG 3060A 30 kg (66 lbs)
Options
CDN 3063A-C32 Three phase 480 V / 32 A automatic coupling decoupling networks for Burst/EFT up to 4.8 kV, Surge, Ring Wave pulses up to 6,6 kV
CDN 3063A-C63 Three phase 480 V / 63 A automatic coupling decoupling network for Burst/EFT up to 4.8 kV, Surge, Ring Wave pulses up to 6,6 kV
CDN 3063A-C100 Three phase 480 V / 100 A automatic coupling decoupling network for Burst/EFT up to 4.8 kV, Surge, Ring Wave pulses up to 6,6 kV
CDN 3425 Burst EFT capacitive coupling clamp for data line coupling per IEC 61000-4-4
CDN 117A-C6-4-1 Coupling networks for unsymmetrical signal-/data lines (surge)
CDN 118A-C6-4-1 Coupling networks for symmetrical signal-/data lines (surge)
CDN HSS-2 Coupling network for 2 kV surge pulse 1.2 / 50 μs IEC/EN 61000 4-5 on unshielded symmetrical high speed telecom lines (Ethernet)
PVF BKIT 1 Burst/EFT verification set
MD 210 Voltage differential probe 7 kV common / differential 1000:1 / 100:1
MD 300 Current probe 5 kA
Accessories for IEC/EN 61000-4-11
TVT 1-250-16 Manual step transformer, 16 AAC, 0/40/70/80%
VAR 3005A-S16 Automatic single variable transformer, 1 x 16 A
Accessories for IEC/EN 61000-4-8/-4-9
MFO 6501A Manual magnetic field option -4-8
MFC 30 Magnetic field coil 1 x 1 m, with MFO max. 40 A/m -4-8;
Surge* max. 1200 A/m -4-9
MFC 300 Magnetic field coil 1 x 1 m; max. 330 A/m -4-8