Overview
Schloder CWG 524-B 60 A Coupling Network Burst
With the coupling network CWG 524-B EMC-tests (susceptibility) on electrical systems and devices can be performed. Basic for these tests is the standard IEC / EN 61000-4-4 (burst). The interference pulse of the burst generator is superposed to the feeding lines of the EUT. Using the coupling switch the coupling paths can be selected.
Technical Data | |
Nominal voltage AC | max. 230 / 400 V, 50-60 Hz; special voltage on demand |
Nominal current IN | 4 x 60 A at TU= 30°Celsius |
Serial choke | 5 x 100 – 150 µH |
Coupling capacity C | 33 nF Surge: phase - PE 9 µF / 10 ? phase - phase 18 µF / 2 ? |
Various coupling paths, selected by switch | L1 - E; L2 - E; L3 - E; N - E; PE – E a.o. |
HV input | Fischer HV-jack D103A023 |
Input coupling network | CECON 63 A |
Output coupling network | CECON 63 A |
Input electronic supply | IEC-plug, 230 V / 1A, on the rear side |
Operation temperature | 0 up to 30° Celsius |
Housing (L x B x T) | 6 HE (19’) compact housing |
Weight | app. 30 kg |