Schloder CWG 524 60A Coupling Network

Manufacturer:
Schloder
Online Orders Ship Same Day

 

SKU:
sku-978

 

This product is available for shipping to North America and Western European countries.


Getting Started...

Check out our Google Reviews

Overview

Schloder CWG 524 60A Coupling Network

With the coupling network CWG 523 / 524 EMC-tests (susceptibility) on electrical systems and devices can be performed. Basic for these tests is the standard IEC / EN 61000-4-4 (burst) and IEC / EN 61000-4-5 (surge).

The interference pulses of the burst and surge-generators are superposed to the feeding lines of the EUT. Using the coupling switch the coupling paths can be selected.

Technical Data
Nominal voltage AC max. 230 / 400 V AC; special voltage on demand
Nominal current IN CWG 523: 4 x 32 A at TU= 30°Celsius
CWG 524: 4 x 60 A at TU= 30°Celsius
Serial choke 5 x 200 µH and 4 x 2,5 mH (/32A or /60A)
Coupling capacity C Burst: 33 nF
Surge:
phase - PE 9 µF / 10 ?
phase - phase 18 µF / 2 ?
Various coupling paths, selected by switch Burst: L1 - E; L2 - E; L3 - E; N - E; PE – E a.o
Surge: L1 - L2; L2 - L3; L1 - L3, a.o.
HV input Burst: Fischer HV-jack D103A023
Surge: Fischer HV-jack D105A039
Input coupling network CECON 63 A
Output coupling network CECON 63 A
Input electronic supply IEC-plug, 230 V / 1A, on the rear side
Operation temperature 0 up to 30° Celsius
Housing (L x B x T) 6 HE (19’’ housing)
Weight CWG 523: app. 65 kg
CWG 524: app. 110 kg

Key Considerations

Manufacturer:
Schloder

Connect with The EMC Shop

Our experienced staff can help you with applications, purchase and rental options.