Overview

Schloder CWG 523 32A Coupling Network

With the coupling network CWG 523 / 524 EMC-tests (susceptibility) on electrical systems and devices can be performed. Basic for these tests is the standard IEC / EN 61000-4-4 (burst) and IEC / EN 61000-4-5 (surge).

The interference pulses of the burst and surge-generators are superposed to the feeding lines of the EUT. Using the coupling switch the coupling paths can be selected.

Technical Data
Nominal voltage AC max. 230 / 400 V AC; special voltage on demand
Nominal current IN CWG 523: 4 x 32 A at TU= 30°Celsius
CWG 524: 4 x 60 A at TU= 30°Celsius
Serial choke 5 x 200 µH and 4 x 2,5 mH (/32A or /60A)
Coupling capacity C Burst: 33 nF
Surge:
phase - PE 9 µF / 10 ?
phase - phase 18 µF / 2 ?
Various coupling paths, selected by switch Burst: L1 - E; L2 - E; L3 - E; N - E; PE – E a.o
Surge: L1 - L2; L2 - L3; L1 - L3, a.o.
HV input Burst: Fischer HV-jack D103A023
Surge: Fischer HV-jack D105A039
Input coupling network CECON 63 A
Output coupling network CECON 63 A
Input electronic supply IEC-plug, 230 V / 1A, on the rear side
Operation temperature 0 up to 30° Celsius
Housing (L x B x T) 6 HE (19’’ housing)
Weight CWG 523: app. 65 kg
CWG 524: app. 110 kg