Maximum Impulse Voltage:
7.5 kV
Maximum AC Voltage:
240 vrms
Maximum DC Voltage:
110 V
Maximum AC and DC Current:
16 A
EUT Connector:
Schuko Socket
Coupling Elements and Paths:
Controlled by the PSURGE 8000
Applications:
EFT/Burst immunity testing, Conducted Immunity/Susceptibility Test Setup
Test Standards:
IEC 61000-4-5
Manufacturer:
Haefely

 

Availability:

In Stock

SKU:
6587

 

This product is available for shipping to North America and Western European countries.


Getting Started...

Check out our Google Reviews

Overview

The Haefely PCD 100 Single Phase Coupling / Decoupling Network for PSURGE 8000 Platform covers IEC and EN standards testing single phase AC mains and DC power ports. They include recommendations for coupling and decoupling characteristics. These recommendations are based on the European model for ac power lines.

IEC and EN standards cover testing of single phase AC mains and DC power ports. They include recommendations for coupling and decoupling characteristics. These recommendations are based on the European model for ac power lines.

The PCD 100 fulfills also the recently approved IEC 61000-4-5 Edition 2.

The ANSI standards contain much the same information as the IEC but based around the American experience with AC power lines.

Impedance of the low voltage mains supply to earth is simulated by the addition of a 10 ohm resistor for IEC tests. ANSI has NO series resistor in the impulse path This difference comes from the practice in Europe of connecting ground to neutral at the distribution transformer, not the power service entry as in the USA. The PCD 100 fulfills all requirements.

The integration in the WinFEAT&R control and reporting software package enhances an efficient set-up and operation of this test system. Most importantly, the test load can be transferred to a computer freeing valuable resources.

Benefits

Safe and easy - The interlocked HC connections allow your operators to test safely and easily.

Sturdy and reliable - Careful component selection ensures that the PCD 100 will continue to operate under the most strenuous testing regime.

Faster completion of testing program - The PCD 100 has two multiplexed inputs, enabling testing to continue with other pulses without having to remove power from EUT.

Applications

  • Single phase power line systems
  • Surge tests with combination wave 1.2/50us - 8/20us and ring wave 100kHz
Technical Specifications
Maximum impulse voltage 7.5kV
Maximum AC voltage 240VRMS
Maximum DC voltage 110V
Maximum AC and DC current 16A
EUT connection Schuko socket
Coupling elements and paths controlled by the PSURGE 8000
Voltage drop due to the decoupling inductors ≤10% with max. current and cos φ ≥0.7
Residual voltage at Test supply input max. 15% of the applied impulse voltage

Videos

Key Considerations

Manufacturer:
Haefely
Maximum Impulse Voltage:
7.5 kV
Maximum AC Voltage:
240 vrms
Maximum DC Voltage:
110 V
Maximum AC and DC Current:
16 A
EUT Connector:
Schuko Socket
Coupling Elements and Paths:
Controlled by the PSURGE 8000
Applications:
EFT/Burst immunity testing, Conducted Immunity/Susceptibility Test Setup
Test Standards:
IEC 61000-4-5

Connect with The EMC Shop

Our experienced staff can help you with applications, purchase and rental options.