AR Electric Field Probes

(Showing 12 of 18)

Amplifier Research has a line of RF electric field monitoring equipment including analyzers and probes. Rent, buy or lease AR RF electric field probes and monitors at The EMC Shop.

Get Application Support, Pricing, Lead Time and More: Contact Form

Show 12

AR Electric Field Probes Test Equipment, Systems & Solutions

  • Amplifier Research PL7004 800MHz - 3.6GHz Electric Field Pulse Laser Powered Probe

    SKU: sku-935

    Amplitude Accuracy: Without correction factors applied: ±1.5 dB @ 1 GHz; With correction factors applied: Typical expanded measurement uncertainty (95% confidence interval), 0.8 dB, 800 MHz–1 GHz; 1.4 dB, 1GHz–3.6 GHz
    Calibration Data: Accredited Calibration Report supplied with probe
    Damage Level: 1000 V/m, Continuous Field or Pulsed Field
    Fiber Optic Connectors: Two E2000 Compact Duplex Connectors at 1 Meter, Includes Fiber Optic Verification Loop.
    Frequency Range: 800MHz - 3.6GHz
    Isotropic Deviation: ±1.0 dB @ 1 GHz. For improved accuracy, this probe should be used with a single axis aligned with the E-field being measured.
    Measurement Data Processing: The pulse amplitude measurement is smoothed before being sampled and digitized. The smoothing process has a time constant of 300 msec.
    Operating Range: 80–800 V/m
    Pulse Duration: 0.02% to 2%
    Pulse Measurement Variation: Over Range of Pulse Width, Period, and Duty relative to a 10 microsecond pulse width and 1 millisecond pulse period (1kHz pulse rate, 1% duty): ±0.5 dB/–1.0 dB typical
    Pulse Period: Up to 5 milliseconds between pulses (greater than 200 Hz pulse rate)
    Pulse Width: 1 to 100 Microseconds
    Relative Flatness: ±2.5 dB, 800 MHz-3 GHz; ±3.0 dB, 3.0GHz 3.6GHz
    Temperature Stability: +0.5 dB Over Operating Temperature Range
  • Amplifier Research FL7030 5 kHz - 30 MHz Electric Field Laser Powered Probe

    SKU: sku-934

    Weight: 62.5 g (2.2 oz)
    Accuracy: ±1.0dB @ 10MHz1 0.8dB, 100kHz–1GHz3,4 1.4dB, 1GHz–6GHz3,4
    Analog Response Time: 20 msec/up to 50 samples per second, at FI7000 USB and GPIB interfaces
    Calibration Data: Accredited Calibration Report (A2LA) supplied with probe
    Damage Level: 1000 V/m continuous field
    Data Returned From Probe: X, Y, Z axes, and Composite
    Dimensions: 5.7 x 5.7 x 5.7 cm (2.25 x 2.25 x 2.25 in) 2.92 cm (1.15 in) DIA spherical housing 3.18 cm (1.25 in) sensor radome per axes
    Fiber Optic Connectors: Two E2000 compact duplex connectors at 1 meter, includes fiber optic verification loop.
    Isotropic Deviation: ± 0.5 dB @ 10 MHz ± 0.5 dB, 5 kHz–30 MHz (typical)
    Linearity: ± 0.5 dB and ± 0.9 V/m
    Operating Range: 1.5–300 V/m
    Operating Temperature: 10˚C to 40˚C (50˚F to 104˚F) @ 5% to 95% RH non-condensing
    Power Requirements: Laser powered from FI7000 interface
    Rise time: Typical Analog 300nS
    Temperature Stability: ± 0.5 dB over operating temperature range
  • Amplifier Research FA7006 6 GHz E-Field Probe Kit

    SKU: sku-933

    Test Standards: IEC 61000-4-3
    Accuracy: ±1.0dB @ 10MHz1 0.8dB, 100kHz–1GHz3,4 1.4dB, 1GHz–6GHz3,4
    Damage Level: 1000 V/m
    Dimensions: 5.7 x 5.7 x 5.7cm
    Linearity: ±0.5dB
    Minimum Pulse Width: 2μs
    Operating Range: 9 – 900V/m
    Rise time: Typical Analog 300nS
    Temperature Stability: ±1.0dB, 10°C - 40°C8
    Typically In Stock
  • Amplifier Research FM7004 100 kHz - 60 GHz Electric Field Monitor

    SKU: sku-913

    Display Interface: IEEE-488 Interface and RS-232 Interface
    Frequency Range: 5 kHz - 60 GHz (probe dependent)
    Input: Up to 4 independent Probes
    Operating Temperature: 0 °C - 40 °C (50 °F - 104 °F) @ 5% - 95% RH non-condensing
    Overload: Probe dependent
    Sampling Rate: 1-60 Samples/sec.
    Sensitivity: 0.4–1000 V/m and 12.0 mA/m–17 A/m
    USB Input: USB 2.0 (test and measurement class)
  • Amplifier Research PM2003 Power Meter, 3 Channel, 10 kHz - 40 GHz, -70dBm to +44dBm

    SKU: sku-805

    Weight: 7 lbs (3.2 kg)
    Dimensions: 8.25 in (21.0 cm) wide, 3.5 in (8.9 cm) high, 13.25 in (33.7 cm) deep
    RF Field Probe Connector: Inputs: Rear panel HEAD connectors and rear panel IEEE-488 connector standard. Outputs: Rear panel PWR/REF connector, 0dBm, 50 MHz. Rear panel RECORDER BNC connector, 0 to 10V into 1mW.
    RF Field Probe Frequency Range: 10 kHz-40 GHz, power head dependent
    RF Field Probe Maximum Input Power: May be operated into 1kW or 1V fs
    RF Field Probe Power Measurement Range: -70dBm to +44dBm, power head dependent
  • Used Amplifier Research PM2002 10 kHz - 40 GHz, -70dBm to +44dBm Power Meter

    SKU: sku-706

    Weight: 7 lbs (3.2 kg)
    Dimensions: 8.25 in (21.0 cm) wide, 3.5 in (8.9 cm) high, 13.25 in (33.7 cm) deep
    RF Field Probe Connector: Inputs: Rear panel HEAD connectors and rear panel IEEE-488 connector standard. Outputs: Rear panel PWR/REF connector, 0dBm, 50 MHz. Rear panel RECORDER BNC connector, 0 to 10V into 1mW.
    RF Field Probe Frequency Range: 10 kHz-40 GHz, power head dependent
    RF Field Probe Maximum Input Power: May be operated into 1kW or 1V fs
    RF Field Probe Power Measurement Range: -70dBm to +44dBm, power head dependent
  • Amplifier Research FP7060 E-Field Probe Kit, 27 MHz – 60GHz, 0.7–300 V/m

    SKU: sku-650

    Weight: 350g approx
    Application/Test Type: electric field measurement instrument for use in EMC and EMI applications
    Battery: 2 built-in NiMH batteries, size AA, rechargeable, changed by operator, 40 hours operating life per charge.
    Communication: 10 m glass cable
    Dimensions: Approx. 420 x 85 x 65 mm including base and probe
    Frequency Range: 27MHz–60GHz
    Measurement Mode: composite values
    Operation Time: 40 hours operating life per charge.
    Recharging Time: Standard recharger included, 3 hour charge time
    RF Field Probes: E-Field
    Sampling Rate: 60Hz, 50Hz, 5 Hz. - user selectable
    Sensors: Isotropic
  • Amplifier Research FI7000 Probe Interface

    SKU: sku-438

    Weight: without enclosure 2.5 kg (6.25 lb) with enclosure 7.25 kg (16 lb)
    Application/Test Type: Monitoring electric field strengths in GTEM's, Anechoic Chambers and other RF rooms for radiated immunity testing.
    Communication: IEEE-488 (GPIB) USB 2.0, Test and Measurement class RS-232 (19200 Baud) Fiber Optic Serial (19200 Baud) reserved for connection to FM7004A Field Monitor Laser Fiber Optic Serial reserved for connection to one FL/PL 7000 series probe
    Dimensions: without enclosure 48.3 x 4.5 x 25.4 cm (19.0 x 1.75 x 10.0 in) with enclosure 49.8 x 12.7 x 30.5 cm (19.6 x 5.0 x 12.0 in)
    RF Connector: (2) E2000 compact duplex female for probe communication and safety fiber loop (2) FSMA for fiber connection to FM7004A
    Standards Met: IEC/EN 61000-4-3
    Supply Voltage: 90-260 VAC, 50-60 Hz

Connect with The EMC Shop