AR Electric Field Probes Test Equipment, Systems & Solutions
-
Amplifier Research FL8040 Laser-Powered E-Field Probe Kit, 20 MHz – 40 GHz, CW & Pulse
SKU: sku-2061
Application/Test Type: Radiated Immunity, Monitoring electric field strengths in GTEM's, Anechoic Chambers and other RF roomsField Strength Range: 0.5 – 800 V/mResolution: 0.01 V/mFrequency Range: 20 MHz – 40 GHzStandards Met: MIL-STD-461 RS103, DO-160 -
Amplifier Research FL8009 Laser-Powered Electric Field Probe Kit, 20 MHz – 9.3 GHz, CW & Pulse
SKU: sku-2060
Application/Test Type: Radiated Immunity, Monitoring electric field strengths in GTEM's, Anechoic Chambers and other RF roomsFrequency Range: 20 MHz – 9.3 GHzTest Standards: IEC 61000-4-3Typically In Stock -
Amplifier Research FL7040/Kit 40 GHz E-Field Probe Kit
SKU: sku-1754
Application/Test Type: Radiated Immunity, Monitoring electric field strengths in GTEM's, Anechoic Chambers and other RF roomsTest Standards: IEC 61000-4-3, MIL 461 RS103Field Strength Range: 2 - 1000 V/mFrequency Range: 2 MHz - 40 GHz -
Amplifier Research PL7004 800MHz - 3.6GHz Electric Field Pulse Laser Powered Probe
SKU: sku-935
Amplitude Accuracy: Without correction factors applied: ±1.5 dB @ 1 GHz; With correction factors applied: Typical expanded measurement uncertainty (95% confidence interval), 0.8 dB, 800 MHz–1 GHz; 1.4 dB, 1GHz–3.6 GHzCalibration Data: Accredited Calibration Report supplied with probeDamage Level: 1000 V/m, Continuous Field or Pulsed FieldFiber Optic Connectors: Two E2000 Compact Duplex Connectors at 1 Meter, Includes Fiber Optic Verification Loop.Frequency Range: 800MHz - 3.6GHzIsotropic Deviation: ±1.0 dB @ 1 GHz. For improved accuracy, this probe should be used with a single axis aligned with the E-field being measured.Measurement Data Processing: The pulse amplitude measurement is smoothed before being sampled and digitized. The smoothing process has a time constant of 300 msec.Operating Range: 80–800 V/mPulse Duration: 0.02% to 2%Pulse Measurement Variation: Over Range of Pulse Width, Period, and Duty relative to a 10 microsecond pulse width and 1 millisecond pulse period (1kHz pulse rate, 1% duty): ±0.5 dB/–1.0 dB typicalPulse Period: Up to 5 milliseconds between pulses (greater than 200 Hz pulse rate)Pulse Width: 1 to 100 MicrosecondsRelative Flatness: ±2.5 dB, 800 MHz-3 GHz; ±3.0 dB, 3.0GHz 3.6GHzTemperature Stability: +0.5 dB Over Operating Temperature Range -
Amplifier Research FL7030 5 kHz - 30 MHz Electric Field Laser Powered Probe
SKU: sku-934
Weight: 62.5 g (2.2 oz)Accuracy: ±1.0dB @ 10MHz1 0.8dB, 100kHz–1GHz3,4 1.4dB, 1GHz–6GHz3,4Analog Response Time: 20 msec/up to 50 samples per second, at FI7000 USB and GPIB interfacesCalibration Data: Accredited Calibration Report (A2LA) supplied with probeDamage Level: 1000 V/m continuous fieldData Returned From Probe: X, Y, Z axes, and CompositeDimensions: 5.7 x 5.7 x 5.7 cm (2.25 x 2.25 x 2.25 in) 2.92 cm (1.15 in) DIA spherical housing 3.18 cm (1.25 in) sensor radome per axesFiber Optic Connectors: Two E2000 compact duplex connectors at 1 meter, includes fiber optic verification loop.Isotropic Deviation: ± 0.5 dB @ 10 MHz ± 0.5 dB, 5 kHz–30 MHz (typical)Linearity: ± 0.5 dB and ± 0.9 V/mOperating Range: 1.5–300 V/mOperating Temperature: 10˚C to 40˚C (50˚F to 104˚F) @ 5% to 95% RH non-condensingPower Requirements: Laser powered from FI7000 interfaceRise time: Typical Analog 300nSTemperature Stability: ± 0.5 dB over operating temperature range -
Amplifier Research FA7006 6 GHz E-Field Probe Kit
SKU: sku-933
Test Standards: IEC 61000-4-3Accuracy: ±1.0dB @ 10MHz1 0.8dB, 100kHz–1GHz3,4 1.4dB, 1GHz–6GHz3,4Damage Level: 1000 V/mDimensions: 5.7 x 5.7 x 5.7cmLinearity: ±0.5dBMinimum Pulse Width: 2μsOperating Range: 9 – 900V/mRise time: Typical Analog 300nSTemperature Stability: ±1.0dB, 10°C - 40°C8Typically In Stock -
Amplifier Research FM7004 100 kHz - 60 GHz Electric Field Monitor
SKU: sku-913
Display Interface: IEEE-488 Interface and RS-232 InterfaceFrequency Range: 5 kHz - 60 GHz (probe dependent)Input: Up to 4 independent ProbesOperating Temperature: 0 °C - 40 °C (50 °F - 104 °F) @ 5% - 95% RH non-condensingOverload: Probe dependentSampling Rate: 1-60 Samples/sec.Sensitivity: 0.4–1000 V/m and 12.0 mA/m–17 A/mUSB Input: USB 2.0 (test and measurement class) -
Amplifier Research FM5004 E and H Field Monitor
SKU: sku-912
Display Interface: IEEE-488 Interface and RS-232 InterfaceFrequency Range: 10 kHz - 40 GHzInput: Up to 4 independent ProbesOverload: Probe dependentSensitivity: 0.15-3000 V/m; 15.0 mA/m - 30 A/m -
Amplifier Research PM2003 Power Meter, 3 Channel, 10 kHz - 40 GHz, -70dBm to +44dBm
SKU: sku-805
Weight: 7 lbs (3.2 kg)Dimensions: 8.25 in (21.0 cm) wide, 3.5 in (8.9 cm) high, 13.25 in (33.7 cm) deepRF Field Probe Connector: Inputs: Rear panel HEAD connectors and rear panel IEEE-488 connector standard. Outputs: Rear panel PWR/REF connector, 0dBm, 50 MHz. Rear panel RECORDER BNC connector, 0 to 10V into 1mW.RF Field Probe Frequency Range: 10 kHz-40 GHz, power head dependentRF Field Probe Maximum Input Power: May be operated into 1kW or 1V fsRF Field Probe Power Measurement Range: -70dBm to +44dBm, power head dependent -
Used Amplifier Research PM2002 10 kHz - 40 GHz, -70dBm to +44dBm Power Meter
SKU: sku-706
Weight: 7 lbs (3.2 kg)Dimensions: 8.25 in (21.0 cm) wide, 3.5 in (8.9 cm) high, 13.25 in (33.7 cm) deepRF Field Probe Connector: Inputs: Rear panel HEAD connectors and rear panel IEEE-488 connector standard. Outputs: Rear panel PWR/REF connector, 0dBm, 50 MHz. Rear panel RECORDER BNC connector, 0 to 10V into 1mW.RF Field Probe Frequency Range: 10 kHz-40 GHz, power head dependentRF Field Probe Maximum Input Power: May be operated into 1kW or 1V fsRF Field Probe Power Measurement Range: -70dBm to +44dBm, power head dependent -
Amplifier Research FP7060 E-Field Probe Kit, 27 MHz – 60GHz, 0.7–300 V/m
SKU: sku-650
Weight: 350g approxApplication/Test Type: electric field measurement instrument for use in EMC and EMI applicationsBattery: 2 built-in NiMH batteries, size AA, rechargeable, changed by operator, 40 hours operating life per charge.Communication: 10 m glass cableDimensions: Approx. 420 x 85 x 65 mm including base and probeFrequency Range: 27MHz–60GHzMeasurement Mode: composite valuesOperation Time: 40 hours operating life per charge.Recharging Time: Standard recharger included, 3 hour charge timeRF Field Probes: E-FieldSampling Rate: 60Hz, 50Hz, 5 Hz. - user selectableSensors: Isotropic -
Amplifier Research FI7000 Probe Interface
SKU: sku-438
Weight: without enclosure 2.5 kg (6.25 lb) with enclosure 7.25 kg (16 lb)Application/Test Type: Monitoring electric field strengths in GTEM's, Anechoic Chambers and other RF rooms for radiated immunity testing.Communication: IEEE-488 (GPIB) USB 2.0, Test and Measurement class RS-232 (19200 Baud) Fiber Optic Serial (19200 Baud) reserved for connection to FM7004A Field Monitor Laser Fiber Optic Serial reserved for connection to one FL/PL 7000 series probeDimensions: without enclosure 48.3 x 4.5 x 25.4 cm (19.0 x 1.75 x 10.0 in) with enclosure 49.8 x 12.7 x 30.5 cm (19.6 x 5.0 x 12.0 in)RF Connector: (2) E2000 compact duplex female for probe communication and safety fiber loop (2) FSMA for fiber connection to FM7004AStandards Met: IEC/EN 61000-4-3Supply Voltage: 90-260 VAC, 50-60 Hz