Amplifier Research FL7030 5 kHz - 30 MHz Electric Field Laser Powered Probe

Weight:
62.5 g (2.2 oz)
Accuracy:
±1.0dB @ 10MHz1 0.8dB, 100kHz–1GHz3,4 1.4dB, 1GHz–6GHz3,4
Analog Response Time:
20 msec/up to 50 samples per second, at FI7000 USB and GPIB interfaces
Calibration Data:
Accredited Calibration Report (A2LA) supplied with probe
Damage Level:
1000 V/m continuous field
Data Returned From Probe:
X, Y, Z axes, and Composite
Dimensions:
5.7 x 5.7 x 5.7 cm (2.25 x 2.25 x 2.25 in) 2.92 cm (1.15 in) DIA spherical housing 3.18 cm (1.25 in) sensor radome per axes
Fiber Optic Connectors:
Two E2000 compact duplex connectors at 1 meter, includes fiber optic verification loop.
Isotropic Deviation:
± 0.5 dB @ 10 MHz ± 0.5 dB, 5 kHz–30 MHz (typical)
Linearity:
± 0.5 dB and ± 0.9 V/m
Operating Range:
1.5–300 V/m
Operating Temperature:
10˚C to 40˚C (50˚F to 104˚F) @ 5% to 95% RH non-condensing
Power Requirements:
Laser powered from FI7000 interface
Rise time:
Typical Analog 300nS
Temperature Stability:
± 0.5 dB over operating temperature range
Manufacturer:
Amplifier Research
Online Orders Ship Same Day

 

SKU:
sku-934

 

This product is available for shipping to North America and Western European countries.


Getting Started...

Check out our Google Reviews

Overview

Amplifier Research FL7030 5 kHz - 30 MHz Electric Field Laser Powered Probe

Is a smart, fast, extremely accurate electric field probe that contains an internal microprocessor to provide linearization, temperature compensation, control, and communication functions. Noise reduction and temperature compensation allow accurate measurements down to 1.5 V/m without zero adjustment. When rotated about its critical angle mount, the probe provides isotropic response of ±0.5 dB over its specified frequency range.

The FL7030 is laser powered to allow for continuous operation without battery recharging or replacement.

Correction factors are provided with the probe. These factors can be loaded into the Model FM7004 Field Monitor (sold separately) to automatically correct the probe readings at user-specified frequencies. When correction factors are applied, the true accuracy of the probe can be realized.

It communicates and is powered through glass fiber optic cables, up to 100 meters long, to the FI7000 interface. X, Y, Z, and isotropic readings can be returned through an FI7000 in 20 msec.

The FL7030 extends the range of AR laser powered E–field probes down to 5 kHz. It offers an extended post–detection response-smoothing time constant to provide more consistent readings for carrier frequencies down to 5 kHz.


FL7030 Typical Uncalibrated Frequency Response

FL7030 Typical Calibrated Frequency Response
(with correction factors applied)

Amplifier Research FL7030 Typical Uncalibrated Frequency Response

Amplifier Research FL7030 Typical Calibrated Frequency Response

Key Considerations

Manufacturer:
Amplifier Research
Weight:
62.5 g (2.2 oz)
Accuracy:
±1.0dB @ 10MHz1 0.8dB, 100kHz–1GHz3,4 1.4dB, 1GHz–6GHz3,4
Analog Response Time:
20 msec/up to 50 samples per second, at FI7000 USB and GPIB interfaces
Calibration Data:
Accredited Calibration Report (A2LA) supplied with probe
Damage Level:
1000 V/m continuous field
Data Returned From Probe:
X, Y, Z axes, and Composite
Dimensions:
5.7 x 5.7 x 5.7 cm (2.25 x 2.25 x 2.25 in) 2.92 cm (1.15 in) DIA spherical housing 3.18 cm (1.25 in) sensor radome per axes
Fiber Optic Connectors:
Two E2000 compact duplex connectors at 1 meter, includes fiber optic verification loop.
Isotropic Deviation:
± 0.5 dB @ 10 MHz ± 0.5 dB, 5 kHz–30 MHz (typical)
Linearity:
± 0.5 dB and ± 0.9 V/m
Operating Range:
1.5–300 V/m
Operating Temperature:
10˚C to 40˚C (50˚F to 104˚F) @ 5% to 95% RH non-condensing
Power Requirements:
Laser powered from FI7000 interface
Rise time:
Typical Analog 300nS
Temperature Stability:
± 0.5 dB over operating temperature range

Connect with The EMC Shop

Our experienced staff can help you with applications, purchase and rental options.