Overview
DFS 4002A meets the test requirements of LV 124 (E10, E13, E14) and LV 148 (E48-09) of German automobile manufacturers. It is equipped with 16-channel switch, with rated current of 100 uA – 2A for each channel.
Features:
- Equipped with mains supply switch (100 A), and signal / data line switch (2 A)
- Equipped with 16 independent channels, switchable, programmable to have any channels
- Equipped with independent ground loop
- Rise / fall time: < 1 µs
Application Areas:
- Automobile
Technical Parameters |
|
Channels |
16 independent channels, switchable, programmable to have any channels; |
EUT Voltage |
Max ±60 V DC |
EUT Current |
100 µA - 2 A (each channel, at 25 °C) |
Polarity |
+/- |
Repetition Rate |
0.001s - 99.9s (or as customized) |
T rise, T fall |
< 1 µs ( @ 1 kΩ;@ 1 Ω (V = 2 V)) |
Switch Impedance |
< 500 Ohm |
Interruption Time |
1 µs (10% +/-1us) - (or as customized) |
Synchronization |
Can be operated with PFS 60xxA (Power Failure Simulator), Synchronization error: <1 µs |
Peak Current |
5 A |
General Parameters |
|
Main Control |
Same as PFS 60xxA |
Display |
5.7” TFT touch screen |
Power Supply Range |
AC 110V/220V±10%,50/60Hz±5% |
Max Power |
200 W |
Dimension |
19”/ 4 U |
Weight |
About 18Kg |
Temperature |
15-35℃ |
Humidity |
45% - 75% |
Air Pressure |
86kPa – 106kPa |