Surge, EFT, PQF, Ring Wave Immunity System for 3 Phase, 100 Amp EUT

Condition:
Used
Standards Met:
IEC/EN 61000-4-4, IEC/EN 61000-4-5, IEC/EN 61000-4-11, IEC/EN 61000-4-12 IEC/EN 61000-4-29
Applications:
Electrical Transient and Noise, Surge Immunity, Power Failures
Max EUT Voltage:
480 VAC and 1,000 VDC
Max EUT Current:
100 Amps (Per Phase)
Peak inrush current capability:
500 Amps
EFT/Burst Pulse Output Capability:
5.5 kV
Combination/Wave Surge Output Capability:
6.6 kV
Ring Wave:
100 kHz, 6 kV
Manufacturer:
EM Test

Downloads

EM Test UCS 500M6 Manual and Specs

EM Test CNI 503 CDN Manual and Specs

EM Test Surge, EFT, PQF, Ring Wave Immunity System

 

Online Orders Ship Same Day

 

Availability:

RENTAL ONLY

SKU:
sku-2169

 

EM Test Surge, EFT, PQF, Ring Wave Immunity System

This EM Test Rack has four transient tests (Surge, Ring, EFT, PQF) with a built in 3 phase, 100 amp, 480 volt coupling network.

CNI 503 B9/100A 3 phase Coupling/Decoupling Network

Product Information Combined Coupling/Decoupling Networks for Burst and Surge CNI 503 The coupling/decoupling network type CNI 503 is used for two different applications:

1.Coupling of Surge and EFT/burst pulses as per IEC 61000-4-4 Ed.2 and IEC 61000-4-5 Ed.2 onto single phase or three-phase power mains supply lines.

2.Decoupling of the transient pulses from the public power mains supply to avoid disturbance of other equipment connected to the mains.

EM Test UCS500M6B Transient Simulator

The EM Test UCS500M/6B transient simulator tests to ANSI/IEEE C62.41, IEC 61000-4-4, -5, -11, -12 & -29 specifications for burst, surge, voltage dips, power frequency, power fail simulation, and ringwave. Design of this simulator exceeds all current standard parameters and it has the capability to support future modifications. A built-in 3 Phase CDN accommodates EUT supply and includes output for external networks. Can be operated from the front panel or remotely, via standard windows-based software.

Videos

Equipment Specifications

Manufacturer:
EM Test
Standards Met:
IEC/EN 61000-4-4, IEC/EN 61000-4-5, IEC/EN 61000-4-11, IEC/EN 61000-4-12 IEC/EN 61000-4-29
Applications:
Electrical Transient and Noise, Surge Immunity, Power Failures
Max EUT Voltage:
480 VAC and 1,000 VDC
Max EUT Current:
100 Amps (Per Phase)
Peak inrush current capability:
500 Amps
EFT/Burst Pulse Output Capability:
5.5 kV
Combination/Wave Surge Output Capability:
6.6 kV
Ring Wave:
100 kHz, 6 kV

Connect with The EMC Shop