Overview
The Solar 6220-1A Audio Isolation Transformer was especially designed for screen room use in making conducted audio frequency susceptibility tests as required by MIL-STD-461/462 and other EMI specifications. It provides a convenient bench model unit with three-way binding posts on primary and output voltmeter leads. Standard 0.75" spacing of binding posts allows use of standard plugs. High current secondary uses 1/4-20 threaded studs.
The transformer may also be used as a pickup device to measure low frequency EMI currents at lower levels than conventional current probes.
[split]
Primary: Less than 5 Ω |
Secondary: One-fourth the primary impedance |
Frequency response: 30 Hz to 250 kHz |
Audio power: 200 W |
Dielectric test: 600 V DC primary to secondaries and each winding to end bells |
Secondary saturation: 50 A AC or DC maximum |
Turns ratio: Two-to-one step down |
Secondary inductance: Approximately 1.0 mH (unloaded) |
Weight: 18 pounds |
Size: 4.5" wide x 5.25 " high x 6.25" deep plus terminals. (11.43 cm x 13.335 cm x 15.875 cm) |