ANSI C63.4

(Showing 2 of 26)

American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz. The EMC Shop stocks test equipment and mobile test sites for quick setup and measurement of product emissions according to ANSI 63.

The EMC Shop stocks equipment and materials to accomplish ANSI C63.4 testing.

Get Application Support, Pricing, Lead Time and More: Contact Form

ANSI C63.4 COVERS:

ANSI C63.4, conducted emission testing, conducting ground plane, digital equipment, electric field measurement, line impedance stabilization network, low-voltage electrical equipment, low-voltage electronic equipment, magnetic field measurement, normalized site attenuation, radiated emission testing, radio-noise emissions, radio-noise power, site attenuation, unintentional radiators

  1. Measurement Instrumentation
  2. Test Faciliteis
  3. EUT arrangements, configuration and operation
  4. AC power line conducted emissions measurements
  5. Radiated emissions measurements
  6. Radio Noise Power
  7. Test Reports
  8. Measurement of ITE
  9. Measurement of unintentional radiators other than ITE
  10. Measurement of intentional radiators
  11. Limit relaxation for transients

SAMPLE SITE VALIDATION TEST SETUP - ANSI 63.4

ANSI C63.4 Test Site Validation Setup for Emissions Measurements

RADIATED EMISSIONS MEASUREMENTS:

Show 12 24

ANSI C63.4 Test Equipment, Systems & Solutions

  • PMM L3-64 3-Phase, 64 Amp LISN for FCC Part 15

    SKU: 10057

    Weight: 50 kg (110 pounds)
    Application/Test Type: Ancillary device intended for repeatable and accurate measurement of the disturbance voltage that an EUT (Equipment Under Test) may inject into the power line or mains.
    Current Rating: 63 Amps Max
    Dimensions: 465 x 450 x 740 mm (18 x 17.7 x 29 inches)
    Frequency Range: 9 kHz to 30 MHz
    Inductors: 50 Ω // [5 Ω + 50 µH] with 250 µH choke
    Mains & EUT Connections: 63 A IEC connector
    RF Connector: BNC (f)
    Standards Met: CISPR 16-1-2; VDE 0876; FCC part 15; MIL-STD 461F
    Voltage Rating: 230 Volts AC, 325 Volts DC (Line to Power Earth and Neutral to Power Earth); 400 Volts AC, 565 Volts DC (line to line and line to neutral)
    CISPR 16-1-2: Yes
    DO-160F: Yes
    CISPR 22: Yes
    FCC: Yes
    ANSI C63.4: Yes
  • PMM L3-32 Four Line 3-Phase LISN w/ V-Network, 32 Amps AC+DC

    SKU: 8784

    Application/Test Type: Measurement on AC 3-phase power circuits from DC to 60 Hz
    Current Rating: 32 Amps with IEC plug; 16 Amps with Schuko plug
    Frequency Range: 9 kHz to 30 MHz
    Inductors: 50 Ω // [5 Ω + 50 µH] with 250 µH choke
    Mains & EUT Connections: 32 A IEC connector; 16 A SCHUKO connector
    RF Connector: BNC (f)
    Standards Met: VDE 0876, CISPR 16-1-2, FCC Part 15
    Voltage Rating: 230 Volts AC and 325 Volts DC (Single Phase L-N, L-PE, N-PE and Three Phase L-PE and N-PE); 400 Volts AC and 565 Volts DC (Three Phase L-L, L-N)
    Additional Standards Met: DO-160F, CISPR 22, ANSI C63.4
    Typically In Stock