IEC 61000-4-6 CDNs for Power Supply Lines Test Equipment, Systems & Solutions
-
CDN-M3-32A-HV AC + DC 1000V RF Coupling/Decoupling Network
SKU: 12165
Application/Test Type: unscreened supply lines (mains) AC + DC, RF Conducted DisturbancesCurrent Rating: up to 32 AmpsMax Voltage: up to 1,000 VoltsFrequency Range: 150 kHz to 230 MHzMains & EUT Connections: banana socketsRF Connector: 50 Ω BNC (Female)Standards Met: IEC / EN 61000-4-6Inquire for Availability -
-
-
-
Teseq CDN M016 Switchable 16 Amp Coupling/Decoupling Network
SKU: sku-827
Weight: 3.3 Lbs (1.5 kg)Application/Test Type: switchable 2 or 3 power lines, (L+N or L+N+PE)Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 ΩCurrent Rating: 16 AmpsDecoupling of Common Mode Disturbance: 150 kHz: Greater than 30 dB 1.5 MHz: Greater than 60 dB 30 MHz: Greater than 40 dB 230 MHz: Greater than 20 dBDimensions: 3.9" x 3.9" x 9.5" (100 mm x 100 mm x 240 mm)Frequency Range: 150 kHz to 230 MHzInsertion Loss: Less than 0.1 dBMains & EUT Connections: 4 mm bananaRF Connector: BNC 50 ΩRF Input Voltage: 30 Volts (Max)Standards Met: IEC/EN 61000-4-6Voltage Division Factor: 150 kHz to 80 MHz: 9.5 dB ±1 dB 80 MHz to 230 MHz: 9.5 dB +3 dB / -2 dBVoltage Rating: AC max. voltage (line to ground): 250 V DC max. voltage (line to ground): 400 V; 3 kV DC, 2 sec$195.00Typically In Stock -
Schloder M Type CDN's for Disturbance Signals to Unscreened Supply Lines (mains) AC + DC up to 1000V, 100A
SKU: sku-791
Application/Test Type: unscreened supply lines (mains) AC + DCCurrent Rating: 16A / 32A / 63 A / 100 ADimensions: 160 x 84,5 x 240mm or 200 x 122,5 x 400mm depending on modelFrequency Range: 150 kHz to 230 MHzMains & EUT Connections: banana socketsRF Connector: 50 Ω BNC (Female)Standards Met: IEC / EN 61000-4-6Voltage Rating: up to 250 VAC / 400 VDC -
Teseq CDN M5 5-Line Coupling Network for AC Power Lines, 16-32 Amps
SKU: sku-227
Weight: 6.5 kg (14.3 LB.'s)Application/Test Type: 5 mains AC power lines emissions testing up to 32 Amps (3L+N+PE)Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 ΩCurrent Rating: 32 Amps MaximumDecoupling of Common Mode Disturbance: Greater than 30 dBDimensions: 6.3 x 6.3 x 20 inches (16.0 cm x 16.0 cm x 50.0 cm)Frequency Range: 150 kHz to 230 MHz (Optional 10 kHz - 80 MHz)Insertion Loss: Greater than 0.1 dBMains & EUT Connections: 4 mm, safety (Optional IEC 320 16A)RF Connector: BNC, 50 ΩRF Input Voltage: Less than 30 VStandards Met: IEC 61000-4-6Voltage Division Factor: 10 dB +3 dB / -1 dBVoltage Rating: AC max. voltage (line to ground) / (line to line): 250 V / 433 V (CDN M216-1000V: 500 V / 1000 V); DC max. voltage (line to ground) / (line to line): 400 V / 800 V (CDN M216-1000V: 1000 V / 2000 V); Test voltage: 3 kV DC, 2 sec -
Com-Power CDN-M525E 5-Line Coupling Decoupling Network for Unscreened Power Lines
SKU: sku-91
Weight: 5 lbs. 2.3 kgApplication/Test Type: five conductor power cableCommon Mode Impedance: 150 kHz - 26 MHz: 150Ω ± 20Ω 26 MHz - 80 MHz: 150Ω + 60Ω / – 45Ω 80 MHz - 230 MHz: 150Ω + 60Ω / – 60ΩCurrent Rating: 25 Amps AC / 17 Amps DC (Max)Decoupling of Common Mode Disturbance: ≥ 40dB (EUT/AE)Dimensions: 6 x 6 x 13 inches 15.2 x 15.2 x 33 cmFrequency Range: 150 kHz to 230 MHzMains & EUT Connections: 4 mm shrouded banana socketsRF Connector: 50 Ω BNC (Female)RF Input Voltage: 40 V (Max)Standards Met: IEC / EN 61000-4-6Voltage Division Factor: 9.5 dB +4 / -1Voltage Rating: 250 V AC / 350 V DC (Line to Ground) -
Com-Power CDN-M425E 3-Phase + Earth Coupling Decoupling Network
SKU: sku-90
Weight: 5 lbs. 2.3 kgApplication/Test Type: Four conductor power cableCommon Mode Impedance: 150 kHz - 26 MHz: 150Ω ± 20Ω 26 MHz - 80 MHz: 150Ω + 60Ω / – 45Ω 80 MHz - 230 MHz: 150Ω + 60Ω / – 60ΩCurrent Rating: 25 Amps AC / 17 Amps DC (Max)Decoupling of Common Mode Disturbance: ≥ 40dB (EUT/AE)Dimensions: 6 x 6 x 13 inches 15.2 x 15.2 x 33 cmFrequency Range: 150 kHz to 230 MHzMains & EUT Connections: 4 mm shrouded banana socketsRF Connector: 50 Ω BNC (Female)RF Input Voltage: 40 V (Max)Standards Met: IEC / EN 61000-4-6Voltage Division Factor: 9.5 dB +4 / -1Voltage Rating: 250 V AC / 350 V DC (Line to Ground) -
Com-Power CDN-M125E Coupling Decoupling Network
SKU: sku-20
Weight: 5 lbs. 2.3 kgApplication/Test Type: Single conductor power cableCommon Mode Impedance: 150 kHz - 26 MHz: 150Ω ± 20Ω 26 MHz - 80 MHz: 150Ω + 60Ω / – 45Ω 80 MHz - 230 MHz: 150Ω + 60Ω / – 60ΩCurrent Rating: 25 Amps AC / 17 Amps DC (Max)Decoupling of Common Mode Disturbance: ≥ 40dB (EUT/AE)Dimensions: 6 x 6 x 13 inches 15.2 x 15.2 x 33 cmFrequency Range: 150 kHz to 230 MHzMains & EUT Connections: 4 mm shrouded banana socketsRF Connector: 50 Ω BNC (Female)RF Input Voltage: 40 V (Max)Standards Met: IEC / EN 61000-4-6Voltage Division Factor: 9.5 dB +4 / -1Voltage Rating: 250 V AC / 350 V DC (Line to Ground)