RF Power Line CDN's

(Showing 12 of 30)

The EMC Shop stocks power line coupling decoupling networks for RF conducted immunity testing. The distubance signals are coupled to each conductor in the supply lines according to EN IEC 61000-4-6 standard. The standard M series CDNs have a current rating of 25 Amps. CDNs are available for power supplies from 1 to 5 conductors.

Get Application Support, Pricing, Lead Time and More: Contact Form

RF Power Line CDN's

  • M1 for one line
  • M2 for two lines
  • M2/3 switchable for two or three lines
  • M3 for three lines
  • M4 for lines and
  • M5 for five lines "-10 types" for frequency range 10 kHz to 80 MHz
  • "-3L and -3LN types" for connections without PE "-750V, -760V
  • -1000V types" for higher EUT voltages
Show 12 24

RF Power Line CDN's Test Equipment, Systems & Solutions

  • Teseq CDN M016 Switchable 16 Amp Coupling/Decoupling Network

    SKU: sku-827

    Weight: 3.3 Lbs (1.5 kg)
    Application/Test Type: switchable 2 or 3 power lines, (L+N or L+N+PE)
    Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 Ω
    Current Rating: 16 Amps
    Decoupling of Common Mode Disturbance: 150 kHz: Greater than 30 dB 1.5 MHz: Greater than 60 dB 30 MHz: Greater than 40 dB 230 MHz: Greater than 20 dB
    Dimensions: 3.9" x 3.9" x 9.5" (100 mm x 100 mm x 240 mm)
    Frequency Range: 150 kHz to 230 MHz
    Insertion Loss: Less than 0.1 dB
    Mains & EUT Connections: 4 mm banana
    RF Connector: BNC 50 Ω
    RF Input Voltage: 30 Volts (Max)
    Standards Met: IEC/EN 61000-4-6
    Voltage Division Factor: 150 kHz to 80 MHz: 9.5 dB ±1 dB 80 MHz to 230 MHz: 9.5 dB +3 dB / -2 dB
    Voltage Rating: AC max. voltage (line to ground): 250 V DC max. voltage (line to ground): 400 V; 3 kV DC, 2 sec
    $195.00
    Typically In Stock
  • Fischer Custom Communications FCC-801-M3-16A, 3 Line M Series CDN, 150 kHz – 230MHz, 16 Amp

    SKU: sku-731

    Application/Test Type: 3 Power Conductors
    Common Mode Impedance: Frequency dependent 150 kHz – 26MHz: 150Ω ±20Ω 26MHz – 80MHz: 150Ω +60Ω -45Ω 80MHz –230MHz: 150Ω +60Ω -60Ω
    Current Rating: 16 Amps
    Frequency Range: 150 kHz to 230 MHz
    Mains & EUT Connections: Multi-Contact Safety Socket
    RF Connector: 50 Ω BNC (Female)
    RF Input Voltage: 30 Volts
    Standards Met: IEC / EN 61000-4-6
    Voltage Division Factor: 10dB+1dB/-3dB
    Voltage Rating: DC less than 600V, AC less than 250V
  • Fischer Custom Communications FCC-801-M2-16A, 2 Line M Series CDN for IEC 61000-4-6 Conducted Immunity

    SKU: sku-730

    Application/Test Type: 2 Power Conductors
    Common Mode Impedance: Frequency dependent 150 kHz – 26MHz: 150Ω ±20Ω 26MHz – 80MHz: 150Ω +60Ω -45Ω 80MHz –230MHz: 150Ω +60Ω -60Ω
    Current Rating: 16 Amps
    Frequency Range: 150 kHz to 230 MHz
    Mains & EUT Connections: Multi-Contact Safety Socket
    RF Connector: 50 Ω BNC (Female)
    RF Input Voltage: 30 Volts
    Standards Met: IEC / EN 61000-4-6
    Voltage Division Factor: 10dB+1dB/-3dB
    Voltage Rating: DC less than 600V, AC less than 250V
  • Teseq CDN M5 5-Line Coupling Network for AC Power Lines, 16-32 Amps

    SKU: sku-227

    Weight: 6.5 kg (14.3 LB.'s)
    Application/Test Type: 5 mains AC power lines emissions testing up to 32 Amps (3L+N+PE)
    Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 Ω
    Current Rating: 32 Amps Maximum
    Decoupling of Common Mode Disturbance: Greater than 30 dB
    Dimensions: 6.3 x 6.3 x 20 inches (16.0 cm x 16.0 cm x 50.0 cm)
    Frequency Range: 150 kHz to 230 MHz (Optional 10 kHz - 80 MHz)
    Insertion Loss: Greater than 0.1 dB
    Mains & EUT Connections: 4 mm, safety (Optional IEC 320 16A)
    RF Connector: BNC, 50 Ω
    RF Input Voltage: Less than 30 V
    Standards Met: IEC 61000-4-6
    Voltage Division Factor: 10 dB +3 dB / -1 dB
    Voltage Rating: AC max. voltage (line to ground) / (line to line): 250 V / 433 V (CDN M216-1000V: 500 V / 1000 V); DC max. voltage (line to ground) / (line to line): 400 V / 800 V (CDN M216-1000V: 1000 V / 2000 V); Test voltage: 3 kV DC, 2 sec
  • Teseq CDN M432 32 Amp Coupling/Dcoupling Network

    SKU: sku-226

    Weight: 6.5 kg (14.3 LB.'s)
    Application/Test Type: 4 mains AC power lines emissions testing up to 32 Amps (2L+N+PE), (3L+PE), optional (3L+N)
    Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 Ω
    Current Rating: 32 Amps Maximum
    Decoupling of Common Mode Disturbance: Greater than 30 dB
    Dimensions: 6.3 x 6.3 x 20 inches (16.0 cm x 16.0 cm x 50.0 cm)
    Frequency Range: 150 kHz to 230 MHz (Optional 10 kHz - 80 MHz)
    Insertion Loss: Greater than 0.1 dB
    Mains & EUT Connections: 4 mm, safety (Optional IEC 320 16A)
    RF Connector: BNC, 50 Ω
    RF Input Voltage: Less than 30 V
    Standards Met: IEC 61000-4-6
    Voltage Division Factor: 10 dB +3 dB / -1 dB
    Voltage Rating: AC max. voltage (line to ground) / (line to line): 250 V / 433 V (CDN M216-1000V: 500 V / 1000 V); DC max. voltage (line to ground) / (line to line): 400 V / 800 V (CDN M216-1000V: 1000 V / 2000 V); Test voltage: 3 kV DC, 2 sec
  • Teseq CDN M416 4-Line Coupling/Decoupling Network

    SKU: sku-225

    Weight: 700 grams (1.5 LB.'s)
    Application/Test Type: 3 power lines, (L+N+PE), (2L+PE), (Optional L+L+L)
    Common Mode Impedance: 150 Ω +10/-20 Ω
    Current Rating: 10 Amps Maximum
    Decoupling of Common Mode Disturbance: Greater than 30 dB
    Dimensions: 4.1 x 3 x 5 inches (10.5 x 7.5 x 12.5 cm)
    Frequency Range: 150 kHz to 230 MHz (Optional 10 kHz - 80 MHz)
    Insertion Loss: Greater than 0.1 dB
    Mains & EUT Connections: 4 mm, safety (Optional IEC 320 16A)
    RF Connector: BNC, 50 Ω
    RF Input Voltage: Less than 30 V
    Standards Met: IEC 61000-4-6, CISPR 16-1-2, CISPR 16-2-1 and CISPR 15
    Voltage Division Factor: 20 dB ±1.5 dB
    Voltage Rating: AC max. voltage (line to ground) / (line to line): 250 V / 433 V (CDN M216-1000V: 500 V / 1000 V); DC max. voltage (line to ground) / (line to line): 400 V / 800 V (CDN M216-1000V: 1000 V / 2000 V); Test voltage: 3 kV DC, 2 sec
  • Teseq CDN M316 Coupling/Decoupling Network (CDN) CDN M3 Type

    SKU: sku-224

    Weight: 700 grams (1.5 LB.'s)
    Application/Test Type: 3 power lines, (L+N+PE), (2L+PE), (Optional L+L+L)
    Common Mode Impedance: 150 Ω +10/-20 Ω
    Current Rating: 10 Amps Maximum
    Decoupling of Common Mode Disturbance: Greater than 30 dB
    Dimensions: 4.1 x 3 x 5 inches (10.5 x 7.5 x 12.5 cm)
    Frequency Range: 150 kHz to 230 MHz (Optional 10 kHz - 80 MHz)
    Insertion Loss: Greater than 0.1 dB
    Mains & EUT Connections: 4 mm, safety (Optional IEC 320 16A)
    RF Connector: BNC, 50 Ω
    RF Input Voltage: Less than 30 V
    Standards Met: IEC 61000-4-6, CISPR 16-1-2, CISPR 16-2-1 and CISPR 15
    Voltage Division Factor: 20 dB ±1.5 dB
    Voltage Rating: AC max. voltage (line to ground) / (line to line): 250 V / 433 V (CDN M216-1000V: 500 V / 1000 V); DC max. voltage (line to ground) / (line to line): 400 V / 800 V (CDN M216-1000V: 1000 V / 2000 V); Test voltage: 3 kV DC, 2 sec
  • Teseq CDN M210B Coupling Network with CEE 7/17 EUT Port & IEC 60320 C14 AE Port

    SKU: sku-223

    Weight: 3.3 Lbs (1.5 kg)
    Application/Test Type: switchable 2 or 3 power lines, (L+N or L+N+PE)
    Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 Ω
    Current Rating: 10 Amps
    Decoupling of Common Mode Disturbance: 150 kHz: Greater than 30 dB 1.5 MHz: Greater than 60 dB 30 MHz: Greater than 40 dB 230 MHz: Greater than 20 dB
    Dimensions: 3.9" x 3.9" x 9.5" (100 mm x 100 mm x 240 mm)
    Frequency Range: 150 kHz to 230 MHz
    Insertion Loss: Less than 0.1 dB
    Mains & EUT Connections: AE Euro: IEC 60320 C14 EUT-socket 2lines: CEE 7/17;
    RF Connector: BNC 50 Ω
    RF Input Voltage: 30 Volts Max
    Standards Met: IEC/EN 61000-4-6
    Voltage Division Factor: 150 kHz to 80 MHz: 9.5 dB ±1 dB 80 MHz to 230 MHz: 9.5 dB +3 dB / -2 dB
    Voltage Rating: AC max. voltage (line to ground): 250 V DC max. voltage (line to ground): 400 V; 3 kV DC, 2 sec
    $1,020.00
  • Teseq CDN M1-10 Coupling Network 10 KHz to 80 MHz for PE Lines

    SKU: sku-222

    Weight: 3.3 Lbs (1.5 kg)
    Application/Test Type: switchable 2 or 3 power lines, (L+N or L+N+PE)
    Common Mode Impedance: 10 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 80 MHz: 150 Ω +60 Ω / -45 Ω
    Current Rating: Current max. (no saturation): 300 mA; Current max. (1 s for PE line test): 25 A
    Dimensions: 3.9" x 3.9" x 9.5" (100 mm x 100 mm x 240 mm)
    Frequency Range: 150 kHz to 230 MHz
    Insertion Loss: Less than 0.1 dB
    RF Connector: BNC 50 Ω
    RF Input Voltage: Less than 20 Volts
    Standards Met: IEC/EN 61000-4-6
    Voltage Division Factor: 10 dB ±1 dB
    Voltage Rating: 3 kV DC, 2 sec
    $790.00
  • EM Test (Lüthi) CDN M5 5-Line Coupling/Decoupling Network (L1+L2+L3+N+PE)

    SKU: sku-145

    Application/Test Type: Coupling/decoupling networks for Conducted immunity, mains AC power supply lines
    Current Rating: up to 100 Amps
    Frequency Range: 150 kHz to 300 MHz (150 kHz - 80 MHz at high power)
    Mains & EUT Connections: AE: 4mm safety lab connectors EUT: 4mm safety lab connectors (high-current MC connectors for AE and DUT port on 75 Amp & 100 Amp models)
    RF Input Voltage: 30 V (Max)
    Standards Met: IEC / EN 61000-4-6
    Voltage Rating: up to 750 Volts AC and DC
  • EM Test (Lüthi) CDN M4 4-Line Coupling/Decoupling Network 3 Phase + Earth/Ground

    SKU: sku-144

    Application/Test Type: Coupling/decoupling networks for Conducted immunity, mains AC/DC power supply lines
    Current Rating: up to 100 Amps
    Frequency Range: 150 kHz to 300 MHz (150 kHz - 80 MHz at high current)
    Mains & EUT Connections: AE: 4mm safety lab connectors EUT: 4mm safety lab connectors
    RF Input Voltage: 30 V (Max)
    Standards Met: IEC / EN 61000-4-6
    Voltage Rating: up to 750 Volts AC and DC

Connect with The EMC Shop