RF Power Line CDN's Test Equipment, Systems & Solutions
-
Teseq CDN M016 Switchable 16 Amp Coupling/Decoupling Network
SKU: sku-827
Weight: 3.3 Lbs (1.5 kg)Application/Test Type: switchable 2 or 3 power lines, (L+N or L+N+PE)Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 ΩCurrent Rating: 16 AmpsDecoupling of Common Mode Disturbance: 150 kHz: Greater than 30 dB 1.5 MHz: Greater than 60 dB 30 MHz: Greater than 40 dB 230 MHz: Greater than 20 dBDimensions: 3.9" x 3.9" x 9.5" (100 mm x 100 mm x 240 mm)Frequency Range: 150 kHz to 230 MHzInsertion Loss: Less than 0.1 dBMains & EUT Connections: 4 mm bananaRF Connector: BNC 50 ΩRF Input Voltage: 30 Volts (Max)Standards Met: IEC/EN 61000-4-6Voltage Division Factor: 150 kHz to 80 MHz: 9.5 dB ±1 dB 80 MHz to 230 MHz: 9.5 dB +3 dB / -2 dBVoltage Rating: AC max. voltage (line to ground): 250 V DC max. voltage (line to ground): 400 V; 3 kV DC, 2 sec$195.00Typically In Stock -
Schloder M Type CDN's for Disturbance Signals to Unscreened Supply Lines (mains) AC + DC up to 1000V, 100A
SKU: sku-791
Application/Test Type: unscreened supply lines (mains) AC + DCCurrent Rating: 16A / 32A / 63 A / 100 ADimensions: 160 x 84,5 x 240mm or 200 x 122,5 x 400mm depending on modelFrequency Range: 150 kHz to 230 MHzMains & EUT Connections: banana socketsRF Connector: 50 Ω BNC (Female)Standards Met: IEC / EN 61000-4-6Voltage Rating: up to 250 VAC / 400 VDC -
Fischer Custom Communications FCC-801-M3-16A, 3 Line M Series CDN, 150 kHz – 230MHz, 16 Amp
SKU: sku-731
Application/Test Type: 3 Power ConductorsCommon Mode Impedance: Frequency dependent 150 kHz – 26MHz: 150Ω ±20Ω 26MHz – 80MHz: 150Ω +60Ω -45Ω 80MHz –230MHz: 150Ω +60Ω -60ΩCurrent Rating: 16 AmpsFrequency Range: 150 kHz to 230 MHzMains & EUT Connections: Multi-Contact Safety SocketRF Connector: 50 Ω BNC (Female)RF Input Voltage: 30 VoltsStandards Met: IEC / EN 61000-4-6Voltage Division Factor: 10dB+1dB/-3dBVoltage Rating: DC less than 600V, AC less than 250V -
Fischer Custom Communications FCC-801-M2-16A, 2 Line M Series CDN for IEC 61000-4-6 Conducted Immunity
SKU: sku-730
Application/Test Type: 2 Power ConductorsCommon Mode Impedance: Frequency dependent 150 kHz – 26MHz: 150Ω ±20Ω 26MHz – 80MHz: 150Ω +60Ω -45Ω 80MHz –230MHz: 150Ω +60Ω -60ΩCurrent Rating: 16 AmpsFrequency Range: 150 kHz to 230 MHzMains & EUT Connections: Multi-Contact Safety SocketRF Connector: 50 Ω BNC (Female)RF Input Voltage: 30 VoltsStandards Met: IEC / EN 61000-4-6Voltage Division Factor: 10dB+1dB/-3dBVoltage Rating: DC less than 600V, AC less than 250V -
Teseq CDN M5 5-Line Coupling Network for AC Power Lines, 16-32 Amps
SKU: sku-227
Weight: 6.5 kg (14.3 LB.'s)Application/Test Type: 5 mains AC power lines emissions testing up to 32 Amps (3L+N+PE)Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 ΩCurrent Rating: 32 Amps MaximumDecoupling of Common Mode Disturbance: Greater than 30 dBDimensions: 6.3 x 6.3 x 20 inches (16.0 cm x 16.0 cm x 50.0 cm)Frequency Range: 150 kHz to 230 MHz (Optional 10 kHz - 80 MHz)Insertion Loss: Greater than 0.1 dBMains & EUT Connections: 4 mm, safety (Optional IEC 320 16A)RF Connector: BNC, 50 ΩRF Input Voltage: Less than 30 VStandards Met: IEC 61000-4-6Voltage Division Factor: 10 dB +3 dB / -1 dBVoltage Rating: AC max. voltage (line to ground) / (line to line): 250 V / 433 V (CDN M216-1000V: 500 V / 1000 V); DC max. voltage (line to ground) / (line to line): 400 V / 800 V (CDN M216-1000V: 1000 V / 2000 V); Test voltage: 3 kV DC, 2 sec -
Teseq CDN M432 32 Amp Coupling/Dcoupling Network
SKU: sku-226
Weight: 6.5 kg (14.3 LB.'s)Application/Test Type: 4 mains AC power lines emissions testing up to 32 Amps (2L+N+PE), (3L+PE), optional (3L+N)Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 ΩCurrent Rating: 32 Amps MaximumDecoupling of Common Mode Disturbance: Greater than 30 dBDimensions: 6.3 x 6.3 x 20 inches (16.0 cm x 16.0 cm x 50.0 cm)Frequency Range: 150 kHz to 230 MHz (Optional 10 kHz - 80 MHz)Insertion Loss: Greater than 0.1 dBMains & EUT Connections: 4 mm, safety (Optional IEC 320 16A)RF Connector: BNC, 50 ΩRF Input Voltage: Less than 30 VStandards Met: IEC 61000-4-6Voltage Division Factor: 10 dB +3 dB / -1 dBVoltage Rating: AC max. voltage (line to ground) / (line to line): 250 V / 433 V (CDN M216-1000V: 500 V / 1000 V); DC max. voltage (line to ground) / (line to line): 400 V / 800 V (CDN M216-1000V: 1000 V / 2000 V); Test voltage: 3 kV DC, 2 sec -
Teseq CDN M416 4-Line Coupling/Decoupling Network
SKU: sku-225
Weight: 700 grams (1.5 LB.'s)Application/Test Type: 3 power lines, (L+N+PE), (2L+PE), (Optional L+L+L)Common Mode Impedance: 150 Ω +10/-20 ΩCurrent Rating: 10 Amps MaximumDecoupling of Common Mode Disturbance: Greater than 30 dBDimensions: 4.1 x 3 x 5 inches (10.5 x 7.5 x 12.5 cm)Frequency Range: 150 kHz to 230 MHz (Optional 10 kHz - 80 MHz)Insertion Loss: Greater than 0.1 dBMains & EUT Connections: 4 mm, safety (Optional IEC 320 16A)RF Connector: BNC, 50 ΩRF Input Voltage: Less than 30 VStandards Met: IEC 61000-4-6, CISPR 16-1-2, CISPR 16-2-1 and CISPR 15Voltage Division Factor: 20 dB ±1.5 dBVoltage Rating: AC max. voltage (line to ground) / (line to line): 250 V / 433 V (CDN M216-1000V: 500 V / 1000 V); DC max. voltage (line to ground) / (line to line): 400 V / 800 V (CDN M216-1000V: 1000 V / 2000 V); Test voltage: 3 kV DC, 2 sec -
Teseq CDN M316 Coupling/Decoupling Network (CDN) CDN M3 Type
SKU: sku-224
Weight: 700 grams (1.5 LB.'s)Application/Test Type: 3 power lines, (L+N+PE), (2L+PE), (Optional L+L+L)Common Mode Impedance: 150 Ω +10/-20 ΩCurrent Rating: 10 Amps MaximumDecoupling of Common Mode Disturbance: Greater than 30 dBDimensions: 4.1 x 3 x 5 inches (10.5 x 7.5 x 12.5 cm)Frequency Range: 150 kHz to 230 MHz (Optional 10 kHz - 80 MHz)Insertion Loss: Greater than 0.1 dBMains & EUT Connections: 4 mm, safety (Optional IEC 320 16A)RF Connector: BNC, 50 ΩRF Input Voltage: Less than 30 VStandards Met: IEC 61000-4-6, CISPR 16-1-2, CISPR 16-2-1 and CISPR 15Voltage Division Factor: 20 dB ±1.5 dBVoltage Rating: AC max. voltage (line to ground) / (line to line): 250 V / 433 V (CDN M216-1000V: 500 V / 1000 V); DC max. voltage (line to ground) / (line to line): 400 V / 800 V (CDN M216-1000V: 1000 V / 2000 V); Test voltage: 3 kV DC, 2 sec -
Teseq CDN M210B Coupling Network with CEE 7/17 EUT Port & IEC 60320 C14 AE Port
SKU: sku-223
Weight: 3.3 Lbs (1.5 kg)Application/Test Type: switchable 2 or 3 power lines, (L+N or L+N+PE)Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 ΩCurrent Rating: 10 AmpsDecoupling of Common Mode Disturbance: 150 kHz: Greater than 30 dB 1.5 MHz: Greater than 60 dB 30 MHz: Greater than 40 dB 230 MHz: Greater than 20 dBDimensions: 3.9" x 3.9" x 9.5" (100 mm x 100 mm x 240 mm)Frequency Range: 150 kHz to 230 MHzInsertion Loss: Less than 0.1 dBMains & EUT Connections: AE Euro: IEC 60320 C14 EUT-socket 2lines: CEE 7/17;RF Connector: BNC 50 ΩRF Input Voltage: 30 Volts MaxStandards Met: IEC/EN 61000-4-6Voltage Division Factor: 150 kHz to 80 MHz: 9.5 dB ±1 dB 80 MHz to 230 MHz: 9.5 dB +3 dB / -2 dBVoltage Rating: AC max. voltage (line to ground): 250 V DC max. voltage (line to ground): 400 V; 3 kV DC, 2 sec$1,020.00 -
Teseq CDN M1-10 Coupling Network 10 KHz to 80 MHz for PE Lines
SKU: sku-222
Weight: 3.3 Lbs (1.5 kg)Application/Test Type: switchable 2 or 3 power lines, (L+N or L+N+PE)Common Mode Impedance: 10 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 80 MHz: 150 Ω +60 Ω / -45 ΩCurrent Rating: Current max. (no saturation): 300 mA; Current max. (1 s for PE line test): 25 ADimensions: 3.9" x 3.9" x 9.5" (100 mm x 100 mm x 240 mm)Frequency Range: 150 kHz to 230 MHzInsertion Loss: Less than 0.1 dBRF Connector: BNC 50 ΩRF Input Voltage: Less than 20 VoltsStandards Met: IEC/EN 61000-4-6Voltage Division Factor: 10 dB ±1 dBVoltage Rating: 3 kV DC, 2 sec$790.00 -
EM Test (Lüthi) CDN M5 5-Line Coupling/Decoupling Network (L1+L2+L3+N+PE)
SKU: sku-145
Application/Test Type: Coupling/decoupling networks for Conducted immunity, mains AC power supply linesCurrent Rating: up to 100 AmpsFrequency Range: 150 kHz to 300 MHz (150 kHz - 80 MHz at high power)Mains & EUT Connections: AE: 4mm safety lab connectors EUT: 4mm safety lab connectors (high-current MC connectors for AE and DUT port on 75 Amp & 100 Amp models)RF Input Voltage: 30 V (Max)Standards Met: IEC / EN 61000-4-6Voltage Rating: up to 750 Volts AC and DC -
EM Test (Lüthi) CDN M4 4-Line Coupling/Decoupling Network 3 Phase + Earth/Ground
SKU: sku-144
Application/Test Type: Coupling/decoupling networks for Conducted immunity, mains AC/DC power supply linesCurrent Rating: up to 100 AmpsFrequency Range: 150 kHz to 300 MHz (150 kHz - 80 MHz at high current)Mains & EUT Connections: AE: 4mm safety lab connectors EUT: 4mm safety lab connectorsRF Input Voltage: 30 V (Max)Standards Met: IEC / EN 61000-4-6Voltage Rating: up to 750 Volts AC and DC