Overview
The DMS 200 conducted, differential mode disturbances simulator is controlled by CoreLab control software, which is capable of conducting tests as per IEC 61000-4-19, IEC/EN 60255-22-7 and JJF 1245.4-2019. Together with different optional accessories, every test can be conducted as per different standard requirement.
Features:
- Frequency range 2 kHz~165 kHz;
- Modulated Frequency: 0 ~ 1000 Hz
- Frequency step: liner, logarithmic or fixed;
- CoreLab control software makes test operation easy;
Application Areas:
- Household appliances
- Industries
Technical Parameters (Differential Mode Voltage Disturbances test) |
|
Frequency Range |
2 kHz~150 kHz |
Waveform |
Sinusoidal, Total Harmonic Distortion (THD) <5% |
Open Circuit Voltage |
0.1 V ~20 V |
Load Impedance |
10 Ω, ±30% |
Technical Parameters (Differential Mode Current Disturbances test) |
|
Frequency Range |
2 kHz~150 kHz |
Max. Current |
5 A |
Load Impedance |
1 Ω, ±0.3 Ω |
BNC output |
10:1(0.1 V/A) |
General Parameters |
|
Power Supply |
AC 110/220 V, ±10%, 45 Hz~65 Hz |
Ambient Temperature |
15 ℃ ~ 35 ℃ |
Dimension |
4U |
Weight |
Approx. 20 kg |