Overview
The 3ctest S6/S10/S20 Series is based on the third generation of intelligent multi-function comprehensive simulator. Set the test requirements on the parameter page and all the test procedure can be done automatically with the advantages of integrated system, intelligent control, easy-operation and time-saving. It fully meet the requirements of IEC 61643-1, GB18802.1, UL1449, YD-T1235[1].2 and TB/T 3074 surge standards for MOV, TVS and GDT surge protection device test and for mains surge protection test or scientific research.
As per
- IEC 61643-1
- GB18802.1
- UL1449
- YD-T1235[1].2
- TB/T 3074
| Technical Parameters | |||
| Model | S6 | S10 | S20 |
| Output waveform | 8/20μs?other waveform please see attached table? | ||
| Front time T1 | 8μs±10% | ||
| Wave tail time T2 | 20μs±10% | ||
| Current peak Ip | 100A?1200A?6kA?10kA | 10kA?15kA?20kA | 20kA?30kA?40kA |
| Current output range | 10%-100% | 1kA?100% | 1kA?100% |
| Equivalent output impedance | 50Ω?5Ω?1Ω?0.5Ω | 1Ω?0.75Ω?0.5Ω | 1Ω?0.75Ω?0.5Ω |
| Charging voltage | Up to 6kV | Up to 10kV | Up to 20kV |
| Internal grade energy | I grade | III grade, automatic switch | III grade, manual switch |
| Voltage polarity | +/- (automatic switch) | ||
| Impulse interval | 10s?999s | ||
| Number of continuous impulse | 1?99 | ||
| Charging voltage instability | Less than 1% | ||
| Trigger mode | Automatic or manual, single trigger available | ||
| Trigger malfunction rate | Less than 1% | ||
| Trigger range | 100% rated charging voltage | ||
| Measurement display resolution | Better than 3% | ||
| Insulation strength | ≤500V RMS?common port COMMON to ground reference PE? | ||
| General Data | |||
| Power supply | AC220V±10%?50/60Hz?10A | ||
| Temperature | -10-+40° | ||
| Humidity | 35%-85%RH?no condensation? | ||
| Ground resistance | No more than 0.5Ω | ||
| Dimension | 19 inch 6U | 19 inch 22U | 19 inch 35U |
| Weight | Approx. 35kg | Approx. 120kg | Approx. 200kg |
| No conductive dust, no fire or explosion danger, no corrosive metal and insulation air. Waveform of mains voltage is sine wave. The THD is <5% | |||